Did you mean: CS50-18IO1
Product Datasheet Search Results:
- PSKT250/18IO1
- Powersem
- PSKT250/18IO1
Product Details Search Results:
Abb.com/CS1000-18IO1
{"I(T) Max.(A) On-state Current":"3.0k²","V(T) Max. (V)":"1.8","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"250m","@I(T) (A) (Test Condition)":"3.0k","Package":"TO-200var75","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","dv/dt Min. (V/us)":"1.0k","I(GT) Max. (A)":"300m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"60m","I(TSM) Max. (A)":"17k","t(q) Typ. (s)":"400u"}...
940 Bytes - 17:32:47, 17 November 2024
Abb.com/CS110-18IO1
{"I(T) Max.(A) On-state Current":"180²","V(T) Max. (V)":"1.6","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"120m","@I(T) (A) (Test Condition)":"300","Package":"StF-1/2","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","dv/dt Min. (V/us)":"1.0k","I(GT) Max. (A)":"100m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"15m","I(TSM) Max. (A)":"2.7k","t(q) Typ. (s)":"130u"}...
931 Bytes - 17:32:47, 17 November 2024
Abb.com/CS1300-18IO1
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"1.1k±","I(D) Max. (A) Leakage Current":"60m","I(TSM) Max. (A)":"23k","Package":"TO-200AA","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","@I(T) (A) (Test Condition)":"4.0k","@Temp. (°C) (Test Condition)":"125","V(T) Max. (V)":"1.7","dv/dt Min. (V/us)":"1.0k","I(GT) Max. (A)":"300m","V(GT) Max.(V)":"3.0","Military":"N","t(q) Typ. (s)":"500u"}...
899 Bytes - 17:32:47, 17 November 2024
Abb.com/CS351-18IO1
{"I(T) Max.(A) On-state Current":"1.0k²","V(T) Max. (V)":"1.8","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"200m","@I(T) (A) (Test Condition)":"600","Package":"TO-200var50","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","dv/dt Min. (V/us)":"1.0k","I(GT) Max. (A)":"200m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"40m","I(TSM) Max. (A)":"5.5k","t(q) Typ. (s)":"150u"}...
935 Bytes - 17:32:47, 17 November 2024
Abb.com/CS401-18IO1
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"400","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"5.4k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","@I(T) (A) (Test Condition)":"1.2k","@Temp. (°C) (Test Condition)":"125","V(T) Max. (V)":"2.1","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"200m","V(GT) Max.(V)":"2.5","Military":"N","t(q) Typ. (s)":"200u"}...
887 Bytes - 17:32:47, 17 November 2024
Abb.com/CS50-18IO1
{"I(T) Max.(A) On-state Current":"120²","V(T) Max. (V)":"1.5","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"150","Package":"TO-209AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","dv/dt Min. (V/us)":"1.0k","I(GT) Max. (A)":"100m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"10m","I(TSM) Max. (A)":"1.2k","t(q) Typ. (s)":"130u"}...
924 Bytes - 17:32:47, 17 November 2024
Abb.com/CS70-18IO1
{"I(T) Max.(A) On-state Current":"102","V(T) Max. (V)":"1.7","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"120m","@I(T) (A) (Test Condition)":"300","Package":"StF-M12","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"100m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"15m","I(TSM) Max. (A)":"2.4k","t(q) Typ. (s)":"130u"}...
918 Bytes - 17:32:47, 17 November 2024
Abb.com/TN90-18IO1
{"I(T) Max.(A) On-state Current":"104±","V(T) Max. (V)":"3.1","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"150m","@I(T) (A) (Test Condition)":"410","Package":"StF-M12","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","dv/dt Min. (V/us)":"1.0k","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"20m","I(TSM) Max. (A)":"1.4k","t(q) Typ. (s)":"200u"}...
925 Bytes - 17:32:47, 17 November 2024
Ixys.com/CS1011-18IO1
{"I(T) Max.(A) On-state Current":"1.0k±","Package":"TO-200varM75","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","dv/dt Min. (V/us)":"1.0k","I(GT) Max. (A)":"300m","V(GT) Max.(V)":"3.0","V(T) Max. (V)":"2.1","Military":"N","I(D) Max. (A) Leakage Current":"60m","I(TSM) Max. (A)":"21k","@Temp. (°C) (Test Condition)":"125","@ t(w) (s) (Test Condition)":"8.3m","I(H) Max.(A) Holding Current":"300m","t(q) Typ. (s)":"150u"}...
927 Bytes - 17:32:47, 17 November 2024
Ixys.com/HVL900-18IO1
{"Category":"Discrete Semiconductor Products","Mounting Type":"Chassis Mount","Family":"SCRs - Modules","Current - On State (It (AV)) (Max)":"-","Voltage - Off State":"1800V","Series":"-","Standard Package":"1","Current - On State (It (RMS)) (Max)":"900A","Packaging":"Bulk","Current - Non Rep. Surge 50, 60Hz (Itsm)":"9200A, 10100A","Datasheets":"HVL900","Current - Gate Trigger (Igt) (Max)":"150mA","Package / Case":"Module","Other Related Documents":"SCR Module Selection Guide","Current - Hold (Ih) (Max)":"1...
1364 Bytes - 17:32:47, 17 November 2024
Ixys.com/MCA500-18IO1
{"Category":"Discrete Semiconductor Products","Mounting Type":"Chassis Mount","Family":"SCRs - Modules","Current - On State (It (AV)) (Max)":"545A","Voltage - Off State":"1800V","Series":"-","Standard Package":"1","Current - On State (It (RMS)) (Max)":"1294A","Packaging":"Tray","Current - Non Rep. Surge 50, 60Hz (Itsm)":"16500A @ 50Hz","Datasheets":"Mxx500-1xIO1","Current - Gate Trigger (Igt) (Max)":"300mA","Package / Case":"WC-500","Current - Hold (Ih) (Max)":"1A","Structure":"Common Anode - All SCRs","Num...
1328 Bytes - 17:32:47, 17 November 2024
Ixys.com/MCA700-18IO1W
{"Category":"Discrete Semiconductor Products","Mounting Type":"Chassis Mount","Family":"SCRs - Modules","Current - On State (It (AV)) (Max)":"700A","Voltage - Off State":"1800V","Series":"-","Standard Package":"1","Current - On State (It (RMS)) (Max)":"1331A","Packaging":"Tray","Current - Non Rep. Surge 50, 60Hz (Itsm)":"18200 @ 50MHz","Current - Gate Trigger (Igt) (Max)":"-","Package / Case":"WC-500","Current - Hold (Ih) (Max)":"-","Structure":"Common Anode - All SCRs","Number of SCRs, Diodes":"2 SCRs"}...
1211 Bytes - 17:32:47, 17 November 2024
Documentation and Support
Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:
File Name | File Size (MB) | Document | MOQ | Support |
---|---|---|---|---|
MCC132-18IO1.pdf | 0.09 | 1 | Request | |
MCC162-18IO1.pdf | 0.09 | 1 | Request | |
MCD310-18IO1.pdf | 0.10 | 1 | Request | |
MCD312-18IO1.pdf | 0.10 | 1 | Request | |
MCC310-18IO1.pdf | 0.09 | 1 | Request | |
MCA500-18IO1.pdf | 0.06 | 1 | Request | |
MCC95-18IO1B.pdf | 0.04 | 1 | Request | |
MCK500-18IO1.pdf | 0.06 | 1 | Request | |
MCD225-18IO1.pdf | 0.10 | 1 | Request | |
MCC72-18IO1B.pdf | 0.04 | 1 | Request | |
MCD132-18IO1.pdf | 0.10 | 1 | Request | |
MCD72-18IO1B.pdf | 0.05 | 1 | Request |