LXA0661-LV-X* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 2\u00a0000\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0192\u00a0mm\u00b2 Mechanical Design Height 500...
2420 Bytes - 04:18:34, 16 November 2024
Siemens.com/BVP:275702
LXA0661-LH-X* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 2\u00a0000\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0192\u00a0mm\u00b2 Mechanical Design Height 500...
2419 Bytes - 04:18:34, 16 November 2024
Siemens.com/BVP:275704
LXA0661-LH-Y* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 2\u00a0000\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0192\u00a0mm\u00b2 Mechanical Design Height 850...
2420 Bytes - 04:18:34, 16 November 2024
Siemens.com/BVP:275705
LXA0661-ZR-Z* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 2\u00a0000\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0192\u00a0mm\u00b2 Mechanical Design Height 287...
2420 Bytes - 04:18:34, 16 November 2024
Siemens.com/BVP:275706
LXA0661-ZL-Z* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 2\u00a0000\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0192\u00a0mm\u00b2 Mechanical Design Height 287...
2418 Bytes - 04:18:34, 16 November 2024
Siemens.com/BVP:275708
LXA0661-ZH-Z* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 2\u00a0000\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0192\u00a0mm\u00b2 Mechanical Design Height 1\u...
2427 Bytes - 04:18:34, 16 November 2024
Siemens.com/BVP:275709
LXA0761-LR-X* LX-CHANGE DIRECTION UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 2\u00a0500\u00a0A Connections Conductor cross section / of the (PE)N 1\u00a0586\u00a0mm\u00b2 Mechanical Design Height 287...
2420 Bytes - 04:18:34, 16 November 2024

Documentation and Support

Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:

File NameFile Size (MB)DocumentMOQSupport
BVP:251167.pdf1.381Request
BVP:211200.pdf0.351Request
BVP:262008.pdf0.671Request
BVP:251194.pdf1.381Request
BVP:252834.pdf1.381Request
BVP:251200.pdf1.381Request
BVP:203530.pdf0.551Request
BVP:211153.pdf0.281Request
BVP:254313.pdf1.381Request
BVP:203236.pdf0.711Request
BVP:251179.pdf1.381Request
BVP:203180.pdf0.711Request