861AN00059A Industrial Valves - KBFDG5V-5-33C60N40-X-M2- PE7-H1-11
From Vickers
Feature | Code | Description |
---|---|---|
VALVE TYPE | KBF | (KBF) PROPORTIONAL VALVE WITH INTEGRAL AMPLIFIER & FEEDBACK ARRANGEMENT |
CONTROL TYPE | D | (D) DIRECTIONAL VALVE |
MOUNTING | G | (G) SUBPLATE MOUNTED |
OPERATION | 5 | (5) SOLENOID CONTROLLED PILOT OPERATED |
PRESSURE RATING | V | (V) MAX PRESSURE 310 BAR FOR 5 AND 350 BAR FOR 7,8,10 INTERFACE |
INTERFACE | -5 | (5) NFPA D05, CETOP 5 |
SPOOL TYPE | -33 | (33) BLEED A & B TO T, (STANDARD FLOW PATHS) |
SPRING ARRANGEMENT | C | (C) SPRING CENTERED, DUAL SOLENOID |
RATED FLOW | 60N40 | (60N40) 60 L/MIN (15.8 USGPM) A PORT AND 40 LPM (10.6 USGPM) B PORT |
PILOT SUPPLY | -X | (X) INTERNAL PILOT PRESSURE WITH PRESSURE REDUCER |
PILOT DRAIN | _ | (0) EXTERNAL PILOT DRAIN |
INPUT SIGNAL | -M2 | (M2) 4-20 MA CURRENT DEMAND SIGNAL, ?10V VOLTAGE MONITOR |
ELECTRICAL CONNECTION | -PE7 | (PE7) 7 PIN CONNECTOR WITH PLUG |
COIL VOLTAGE | -H | (H) 24V DC |
TANK PORT RATING | 1 | (1) 4 BAR MAXIMUM |
DESIGN CODE | -11 | DESIGN NUMBER |