02-352598
Industrial Valves - Proportional; directional valve; size D05 NG10; 2-stage; on-board electronics

From Vickers

FeatureCodeDescription
VALVE TYPEKB(KB) PROPORTIONAL VALVE WITH INTEGRAL AMPLIFIER
CONTROL TYPED(D) DIRECTIONAL VALVE
MOUNTINGG(G) SUBPLATE MOUNTED
OPERATION5(5) SOLENOID CONTROLLED / PILOT OPERATED
PRESSURE RATINGV(V) MAX PRESSURE 350 BAR FOR SIZE 7,8,10 & 315 BAR FOR SIZE 5
INTERFACE-5(5) NFPA D05, CETOP 5
SPOOL TYPE-2(2) P,A,B,T BLOCKED
SPRING ARRANGEMENTC(C) SPRING CENTERED, DUAL SOLENOID
RATED FLOW90N(90N) 90 LPM (24 USGPM) AT BOTH SIDE
PILOT SUPPLY_(0) INTERNAL PILOT SUPPLY
PILOT DRAIN_(0) EXTERNAL PILOT DRAIN
MANUAL OVERRIDE_(0) PLAIN OVERRIDES
LVDT PLUG-M1(M1) ?10V VOLT CONTROL SIGNAL
ELECTRICAL CONNECTOR-PE7(PE7) 7 PIN ELECTRICAL PLUG WITH PLUG
COIL VOLTAGE-H(H) 24V DC AMPLIFIER SUPPLY
TANK PORT RATING1(1) 8 BAR PILOT TANK PRESSURE MAXIMUM
DESIGN CODE-10(10) FOR 5,7 & 8 INTERFACE