7KM5412-6CA00-1EA8
7KM PAC5200

From SIEMENS

SENTRON, meas. device & power quality recorder, 7KM PAC5200, standard rail housing w/o display L-L: 690 V, L-N: 400 V, 10 A, strd rail instr., 3- phase, Modbus TCP, apparent/ Active/reactive energy / cos phi, harmonics: 2. - 40., THD, class 0.5 acc. to IEC61557-12 or cl. 0.5S acc. to IEC62053-22, wide-range pwr sup. unit AC/DC, screw terminals
Model
Product brand nameSENTRON
Product designation7KM PAC5200
Design of the productAdvanced
Product type designationMeasuring instrument and power quality recorder
Type of measured value detectioncomplete
Design of the power supplyWide-range power supply
General technical data
Size of Power Monitoring Device / company-specificDIN rail
Operating mode for measured value detection
automatic line frequency detectionYes
set at 50 HzNo
set to 60 HzNo
Pulse duration
initial value50 ms
Full-scale value3 600 000 ms
Voltage curveSinusoidal or distorted
Measurable line frequency / initial value45 Hz
Measurable line frequency / Full-scale value65 Hz
Measuring procedure / for voltage measurementTRMS
Supply voltage
Type of voltage / of the supply voltageAC/DC
Measuring category / for supply voltageCATIII
Apparent power consumption
with expansion module / maximum6 V·A
without expansion module / typical6 V·A
Relative symmetrical tolerance / of the supply voltage20 %
Protection class
Protection class IP
on the frontIP20
Rear sideIP20
Operating resource protection class / when installedII
Electricity
Measurable current / 2 / at AC / Rated value10 A
Suitability
Suitability for operationStandard mounting rail device
Adjustable time period / minimum50 ms
Product function
Product function
Illuminance of display backlighting adjustableNo
Time-controlled reduction of the illuminance of display backlighting possibleNo
reactive power measurementYes
frequency measurementYes
pulse measurementYes
Display contrast adjustableNo
voltage measurementYes
Current measurementYes
active power measurementYes
Display and operation
Design of the displayStandard mounting rail enclosure without display
Number of keys4
Color / of the background of the displaywhite
National language / on the display screen / is supportedde, en
Product function / Display can be inverted (positive <=> negative mode)No
Communication
Refresh time / at the interface
maximum1 s
Number of interfaces / acc. to Fast Ethernet1
Design of cable / connectable / Twisted pairYes
Protocol
is supportedModbus TCP
Fault limits
Reference condition / for metering accuracyaccording to IEC 62053-22, IEC 62053-23, IEC 62586-1, Class S, IEC 61000-4-30, IEC 61000-4-7, IEC 61000-4-15
Formula for relative total measurement inaccuracy
for measured variable reactive energyClass 2 according to IEC61557-12 and/or IEC62053-23
for measured variable output+/- 0,5 %
for measured variable output factor+/- 0,5 %
for measured variable voltage+/- 0,2 %
for measured variable current+/- 0,2 %
for measured variable THD+/- 0.5 %
for measured variable active energyCl. 0.5 acc. to... IEC62053-22
Inputs Outputs
Number of digital outputs2
Digital output versionContinuous output, pulse output
Type of switching outputsolid state
Type of electrical connection
at the digital outputsscrew-type terminals
Output current
at digital output / for signal <1> / minimum100 mA
at digital output / for signal <1> / maximum300 mA
at the digital outputs / at DC / maximum100 mA
Operating voltage / as output voltage / at DC / maximum permissible250 V
Property of the output / Short-circuit proofYes
Internal resistance / at the digital outputs35 Ω
Measuring category / for digital signalsCat. III
Switching frequency / at digital output / maximum10 Hz
Transfer rate
1 / for fast Ethernet10 Mbit/s
2 / for fast Ethernet100 Mbit/s
Measuring inputs
Outer conductors and neutral conductors internal resistance / for voltage measurement6 MΩ
Measurable supply voltage
between (PE)N and L / at AC / maximum rated value400 V
between the outer conductors / at AC / maximum831 V
between the outer conductors / at AC / maximum rated value690 V
Voltage measuring range extension / with external voltage transformersYes
Current measuring range extension / with external current transformersYes
Measuring category / for voltage measurementCATIII
Supply voltage / between the outer conductors / at AC / maximum permissible831 V
Consumed active power / for current measurement / per phase2.5 mW
Continuous current / at AC / maximum permissible10 A
Measuring category / for current measurementCATIII
Zero-point suppression / for current measurement0 ... 10 %
for neutral conductor current0.0 % to 10.0 % (from Vrated, Irated)
Relative measurable current / at AC
minimum1 %
maximum200 %
Apparent power consumption / for current measurement
with measuring range 5 A / per phase2 V·A
Measuring procedure / for current measurementTRMS
Measurable current / 1 / at AC / Rated value1 A
Connections
Type of connectable conductor cross-sections
at the measurement inputs for voltage / at AWG conductors / solidScrew connection
at the measurement inputs for voltage / solid2.5 mm²
at the measurement inputs for voltage / finely stranded / with core end processing2.5 mm²
at the measurement inputs for current / at AWG conductors / solidScrew connection
Type of electrical connection
at the inputs for supply voltagescrew-type terminals
at the measurement inputs for voltagescrew-type terminals
at the measurement inputs for currentscrew-type terminals
of the fast Ethernet interfaceRJ45 (8P8C)
Mechanical Design
Mounting positionvertical
Mounting type / panel mountingNo
Net weight754 g
Environmental conditions
Degree of pollution2
Installation altitude / at height above sea level / maximum2 000 m
Standard
for EMC for industrial sectorIEC 61000-6-2
for EMC against unloadingIEC 61000-4-2 - 6 kV contact discharge; 8 kV air discharge
for EMC against high frequency fieldsIEC 61000-4-3 80 MHz up to 3 GHz, 10 Vm
for EMC against conducted LF disturbance variables (industry)IEC 61000-6-4
for EMC against conducted disturbance variables via HF fieldsIEC 61000-4-6; 2008; 0.15 MHz - 80 MHz
for EMC against magnetic fields with power engineering frequenciesIEC 61000-4-8, Class IV
for EMC against quick, transient electrical disturbancesIEC 61000-4-4 Class 3; 2 kV, 5 KHz
for EMC against voltage drops and interruptionsIEC 61000-4-11; 2004-03
for EMC against surge voltagesIEC 61000-4-5 installation class 2, 2 kV/1 kV,
for free fallIEC 60068-2-31
for cyclic, environmental damp heat checkIEC 60068-2-78 Test Ca
for environmental coldness checkIEC 60068-2-1 Test Ad
for environmental dry heat checkIEC 60068-2-2 Test Bd
Relative humidity / at 25 °C / without condensation / during operation
minimum75 %
maximum95 %
Ambient temperature
during operation / minimum-25 °C
during operation / maximum55 °C
during storage / minimum-40 °C
during storage / maximum70 °C

External links