6GT2811-3BA00-1AA0
RF640R FCC

From SIEMENS

Product type designationRF640R FCC reader
SIMATIC RF600 Reader RF640R FCC; with internal antenna; Interfaces: Ethernet, 2 dig. inputs/ 2 dig. outputs, 24V DC, 1 antenna (R-TNC) can be used as an alternative to the internal antenna; IP65; -25 to +55 °C; without accessories
Suitability for operationRF600 transponder, for connecting to Ethernet networks
Wireless frequencies
Operating frequency902 ... 928 MHz
Transmit power50 ... 1250 mW
Equivalent isotropically radiated power
for each external antenna / maximum4000 mW
minimum100 mW
maximum3300 mW
Range / maximum8 m; Extended ranges possible, see RF600 System Manual, Range table: http://support.automation.siemens.com/WW/view/en/67384964
Protocol / with radio transmissionEPCglobal Class 1 Gen 2 / ISO 18000-6C
Transfer rate / with radio transmission / maximum320 kbit/s
Product feature / multitag-capableYes
PolarizationInternal: circular, external: according to antenna
Electrical data
Transmission time / for user data
for write access / per byte / typical6.3 ms
for read access / per byte / typical1 ms
Interfaces
Number of external antennas1
Standard for interfaces / for communicationEthernet, PROFINET, EtherNet/IP, RS422
Type of electrical connection
for external antenna(s)RP-TNC
for supply voltageM12, 4-pin, female connector
for communications interfacePush-pull RJ45
at the digital inputs/outputsM12, 8-pin, female connector
Number of digital inputs2
Number of digital outputs2
Mechanical data
MaterialAluminum, ABS (GF20)
Colorsilver/anthracite
Mounting distance / relating to metal surfaces / recommended / minimum0 mm
Supply voltage, current consumption, power loss
Supply voltage
at DC / Rated value24 V
at DC20 ... 30 V
Consumed current / at DC / at 24 V
typical0.45 A
maximum1.5 A
Permitted ambient conditions
Ambient temperature
during operation-25 ... +55 °C
during storage-40 ... +85 °C
during transport-40 ... +85 °C
Ambient condition / for operationWith operating temperature below -20 °C: Warming-up time at least 10 minutes
Protection class IPIP65
Shock resistanceEN 60068-2-27, EN 60068-2-6
Shock acceleration500 m/s²
Vibrational acceleration200 m/s²
Design, dimensions and weight
Width193 mm
Height252 mm
Depth52 mm
Net weight2.01 kg
Mounting type4 x M6 screws, Vesa 100 with 4 x M4 screws
Wire length
of antenna cable / minimum1 m
of antenna cable / maximum40 m
Product properties, functions, components / general
Display version3-color LED
Product feature / silicon-freeYes
Standards, specifications, approvals
Certificate of suitabilityWireless according to FCC, IC (Canada), cULus
MTBF14 y
Accessories
accessoriesoptional: External antenna

External links