6GK7443-1GX30-0XE0
Communication processor CP 443-1 ADV

From SIEMENS

Product type designationCP 443-1 Advanced
Communications processor CP 443-1 Advanced 1x 10/100/1000 Mbit/s, 4x 10/100 Mbit/s (IE switch) RJ45 ports; ISO; TCP; UDP; PROFINET IO controller; S7 communication; Open Communication (SEND/RECEIVE); S7 routing; IP configuration via DHCP/block; IP Access Control List; Time synchronization; extended web diagnostics; Fast Startup; PROFIenergy support; IP routing; FTP; Web server; E-mail; PROFINET CBA, security
Transmission rate
Transfer rate
at the 1st interface10 ... 1000 Mbit/s
at the 2nd interface10 ... 100 Mbit/s
Interfaces
Number of interfaces / acc. to Industrial Ethernet5
Number of electrical connections
at the 1st interface / acc. to Industrial Ethernet1
at the 2nd interface / acc. to Industrial Ethernet4
Type of electrical connection
at the 1st interface / acc. to Industrial EthernetRJ45 port
at the 2nd interface / acc. to Industrial EthernetRJ45 port
design of the removable storage / C-PLUGYes
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltageDC
Supply voltage / 1 / from backplane bus5 V
Relative symmetrical tolerance / at DC
at 5 V5 %
Consumed current
from backplane bus / at DC / at 5 V / typical1.8 A
Power loss [W]9 W
Permitted ambient conditions
Ambient temperature
during operation0 ... 60 °C
during storage-40 ... +70 °C
during transport-40 ... +70 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum95 %
Protection class IPIP20
Design, dimensions and weight
Module formatCompact module S7-400 single width
Width25 mm
Height290 mm
Depth210 mm
Net weight0.7 kg
Product properties, functions, components / general
Number of units
per CPU / maximum14
Notemax. 4 as PN IO ctrl.
Performance data / open communication
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum64
Amount of data
as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum2 Kibyte
Number of possible connections / for open communication
by means of T blocks / maximum64
Amount of data
as user data per ISO on TCP connection / for open communication / by means of T blocks / maximum1452 byte
Performance data / S7 communication
Number of possible connections / for S7 communication
maximum128
with PG connections / maximum2
Notewhen using several CPUs
Performance data / multi-protocol mode
Number of active connections / with multi-protocol mode128
Performance data / IT functions
Number of possible connections
as client / by means of FTP / maximum20
as server / by means of FTP / maximum10
Number of possible connections
as server / by means of HTTP / maximum4
as e-mail client / maximum1
Amount of data / as user data for email / maximum8 Kibyte
Storage capacity / of the user memory
as flash memory file system30 Mibyte
as RAM16 Mibyte
additionally buffered as RAM via central backup battery512 Kibyte
Number of possible write cycles / of the flash memory cells100000
Performance data / PROFINET communication / as PN IO-Controller
Product function / PROFINET IO controllerYes
Number of PN IO devices / on PROFINET IO controller / usable / total128
Number of PN IO IRT devices / on PROFINET IO controller / usable64
Number of external PN IO lines / with PROFINET / per rack4
Amount of data
as user data for input variables / as PROFINET IO controller / maximum4 Kibyte
as user data for input variables / as PROFINET IO controller / maximum4 Kibyte
as user data for input variables per PN IO device / as PROFINET IO controller / maximum1433 byte
as user data for output variables per PN IO device / as PROFINET IO controller / maximum1433 byte
as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum240 byte
as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum240 byte
Performance data / PROFINET CBA
Number of remote connection partners / with PROFINET CBA64
Number of connections / with PROFINET CBA / total600
Amount of data
as user data for digital inputs / with PROFINET CBA / maximum8 Kibyte
as user data for digital outputs / with PROFINET CBA / maximum8 Kibyte
as user data for arrays and data types / in the case of acyclic transmission / with PROFINET CBA / maximum8 Kibyte
as user data for arrays and data types / with PROFINET CBA / with cyclical transfer / maximum250 byte
as user data for arrays and data types / with PROFINET CBA / in the case of local interconnection / maximum2400 byte
Performance data / PROFINET CBA / remote connection / with acyclic transmission
Refresh time / of the remote interconnections / in the case of acyclic transmission / with PROFINET CBA100 ms
Number of remote connections to input variables / in the case of acyclic transmission / with PROFINET CBA / maximum150
Number of remote connections to output variables / in the case of acyclic transmission / with PROFINET CBA / maximum150
Amount of data
as user data for remote interconnections with input variables / in the case of acyclic transmission / with PROFINET CBA8 Kibyte
as user data for remote interconnections with output variables / in the case of acyclic transmission / with PROFINET CBA8 Kibyte
Performance data / PROFINET CBA / remote connection / with cyclic transmission
Refresh time / of the remote interconnections / with PROFINET CBA / with cyclical transfer10 ms
Number of remote connections to input variables / with PROFINET CBA / with cyclical transfer / maximum250
Number of remote connections to output variables / with PROFINET CBA / with cyclical transfer / maximum250
Amount of data
as user data for remote interconnections with input variables / with PROFINET CBA / with cyclical transfer / maximum2000 byte
as user data for remote interconnections with output variables / with PROFINET CBA / with cyclical transfer / maximum2000 byte
Performance data / PROFINET CBA / HMI variables via PROFINET / acyclic
Number of connectable HMI stations / for HMI variables / in the case of acyclic transmission / with PROFINET CBA3
Refresh time / of the HMI variables / in the case of acyclic transmission / with PROFINET CBA500 ms
Number of HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum200
Amount of data / as user data for HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum8 Kibyte
Performance data / PROFINET CBA / device-internal connections
Number of internal connections / with PROFINET CBA / maximum300
Amount of data / of the internal connections / with PROFINET CBA / maximum2400 byte
Performance data / PROFINET CBA / connections to constants
Number of connections with constants / with PROFINET CBA / maximum500
Amount of data / as user data for interconnections with constants / with PROFINET CBA / maximum4000 byte
Performance data / PROFINET CBA / PROFIBUS proxy functionality
Product function / with PROFINET CBA / PROFIBUS proxy functionalityNo
Product functions / management, configuration
Product function / MIB supportYes
Protocol / is supported
SNMP v1Yes
SNMP v3Yes
DCPYes
LLDPYes
Configuration software
requiredSTEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher
for PROFINET CBA / requiredSIMATIC iMap V3.0 SP1 and higher
Product functions / Diagnosis
Product function / Web-based diagnosticsYes
Product functions / switch
Product feature / SwitchYes
Product function
switch-managedNo
with IRT / PROFINET IO switchYes
Configuration with STEP 7Yes
Product functions / Redundancy
Product function
Ring redundancyYes
Redundancy managerYes
Protocol / is supported / Media Redundancy Protocol (MRP)Yes
Product functions / Security
Firewall versionstateful inspection
Product function / with VPN connectionIPSec
Type of encryption algorithms / with VPN connectionAES-256, AES-192, AES-128, 3DES-168, DES-56
Type of authentication procedure / with VPN connectionPreshared key (PSK), X.509v3 certificates
Type of hashing algorithms / with VPN connectionMD5, SHA-1
Number of possible connections / with VPN connection32
Product function
password protection for Web applicationsYes
ACL - IP-basedYes
ACL - IP-based for PLC/routingYes
switch-off of non-required servicesYes
Blocking of communication via physical portsYes
log file for unauthorized accessNo
Product functions / Time
Product function / SICLOCK supportYes
Product function / pass on time synchronizationYes
Protocol / is supported
NTPYes