| Compact Switch Module CSM 377 Connection SIMATIC S7-300 and up to 3 further nodes to Industrial Ethernet with 10/100 Mbit/s unmanaged switch, 4 RJ45 ports, External 24 V DC power supply LED diagnostics, S7-300 module, incl. electron. Equipment Manual on CD-ROM |
Product type designation | SCALANCE CSM 377 |
Transmission rate |
Transfer rate | 10 Mbit/s, 100 Mbit/s |
Interfaces / for communication / integrated |
Number of electrical connections | |
for network components or terminal equipment | 4 |
Number of 100 Mbit/s SC ports | |
for multimode | 0 |
Number of 1000 Mbit/s LC ports | |
for multimode | 0 |
for single mode (LD) | 0 |
Interfaces / others |
Number of electrical connections | |
for power supply | 1 |
Type of electrical connection | |
for power supply | 2-pole terminal block |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Supply voltage | |
external | 24 V |
external / minimum | 19.2 V |
external / maximum | 28.8 V |
Product component / fusing at power supply input | Yes |
Fuse protection type / at input for supply voltage | 0.5 A / 60 V |
Consumed current / maximum | 0.07 A |
Power loss [W] | |
at DC / at 24 V | 1.6 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | 0 ... 60 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity | |
at 25 °C / without condensation / during operation / maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight |
Design | SIMATIC S7-300 device design |
Width | 40 mm |
Height | 125 mm |
Depth | 118 mm |
Net weight | 0.2 kg |
Mounting type | |
35 mm DIN rail mounting | No |
wall mounting | No |
S7-300 rail mounting | Yes |
S7-1500 rail mounting | No |
Product functions / management, configuration |
Product function | |
multiport mirroring | No |
Product function / switch-managed | No |
Product functions / Redundancy |
Product function | |
Parallel Redundancy Protocol (PRP)/operation in the PRP-network | Yes |
Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA) | No |
Standards, specifications, approvals |
Standard | |
for FM | FM3611: Class 1, Divison 2, Group A, B, C, D / T.., CL.1, Zone 2, GP. IIC, T.. Ta |
for hazardous zone | EN 60079-15, II 3 G Ex nA II T.., KEMA 06 ATEX 0021 X |
for safety / from CSA and UL | UL 508, CSA C22.2 No. 142 |
for hazardous zone / from CSA and UL | UL 1604 and UL 2279-15 (Hazardous Location) |
for emitted interference | EN 61000-6-4:2001 |
for interference immunity | EN 61000-6-2:2001 |
Standards, specifications, approvals / CE |
Certificate of suitability / CE marking | Yes |
Standards, specifications, approvals / miscellaneous |
Certificate of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 |
C-Tick | Yes |
KC approval | No |
Standards, specifications, approvals / ship classification |
Marine classification association | |
American Bureau of Shipping Europe Ltd. (ABS) | Yes |
Bureau Veritas (BV) | Yes |
Det Norske Veritas (DNV) | Yes |
Germanische Lloyd (GL) | No |
Lloyds Register of Shipping (LRS) | Yes |
Nippon Kaiji Kyokai (NK) | Yes |
Polski Rejestr Statkow (PRS) | No |
Royal Institution of Naval Architects (RINA) | No |
Standards, specifications, approvals / product conformity |
MTBF | 144 y |