Product type designation | CP 342-5 |
| Communications processor CP 342-5 for connection of SIMATIC S7-300 to PROFIBUS DP, S5-compatible, PG/OP and S7 communication |
Transmission rate |
Transfer rate | |
at the 1st interface / acc. to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s |
Interfaces |
Number of interfaces / acc. to Industrial Ethernet | 0 |
Number of electrical connections | |
at the 1st interface / acc. to PROFIBUS | 1 |
for power supply | 1 |
Type of electrical connection | |
at the 1st interface / acc. to PROFIBUS | 9-pin Sub-D socket (RS485) |
for power supply | 4-pole terminal block |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Supply voltage / 1 / from backplane bus | 5 V |
Supply voltage | 24 V |
Supply voltage / external | 24 V |
Supply voltage / external / at DC / Rated value | 24 V |
Relative positive tolerance / at DC / at 24 V | 20 % |
Relative negative tolerance / at DC / at 24 V | 15 % |
Consumed current | |
from backplane bus / at DC / at 5 V / typical | 0.15 A |
from external supply voltage / at DC / at 24 V / typical | 0.25 A |
Power loss [W] | 5 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | 0 ... 60 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight |
Module format | Compact module S7-300 single width |
Width | 40 mm |
Height | 125 mm |
Depth | 120 mm |
Net weight | 0.3 kg |
Mounting type | |
S7-300 rail mounting | Yes |
Product properties, functions, components / general |
Number of units | |
per CPU / maximum | 4 |
Performance data / open communication |
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 16 |
Amount of data | |
as user data per connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 240 byte |
Performance data / PROFIBUS DP |
Service / as DP master | |
DPV0 | Yes |
Number of DP slaves / on DP master / usable | 124 |
Amount of data | |
of the address area of the inputs / as DP master / total | 2160 byte |
of the address area of the outputs / as DP master / total | 2160 byte |
of the address area of the inputs / per DP slave | 244 byte |
of the address area of the outputs / per DP slave | 244 byte |
of the address area of the diagnostic data / per DP slave | 240 byte |
Service / as DP slave | |
DPV0 | Yes |
DPV1 | No |
Amount of data | |
of the address area of the inputs / as DP slave / total | 240 byte |
of the address area of the outputs / as DP slave / total | 240 byte |
Performance data / S7 communication |
Number of possible connections / for S7 communication | |
maximum | 16 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode | |
without DP / maximum | 32 |
with DP / maximum | 28 |
Performance data / telecontrol |
Protocol / is supported | |
TCP/IP | No |
Product functions / management, configuration |
Configuration software | |
required | STEP 7 V5.1 SP2 or higher |