6GK5216-0BA00-2AC2
SCALANCE XC216

From SIEMENS

SCALANCE XC216 manageable layer 2 IE Switch; 16X 10/100 Mbit/s RJ45-Ports; 1x console port, Diagnostic LED; Redundant power supply; Temp. range -40°C to +70 °C Mounting: Standard Mounting Rail/S7 Profile Rail/Wall Office redundancy functions features (RSTP, VLAN ,...); PROFINET IO Device; Ethernet/IP compliance C-PLUG shaft;
Product type designationSCALANCE XC216
Transmission rate
Transfer rate10 Mbit/s, 100 Mbit/s
Interfaces / for communication / integrated
Number of electrical connections
for network components or terminal equipment16; RJ45
Number of 10/100 Mbit/s RJ45 ports / Integrated
with securing collar16
Interfaces / others
Number of electrical connections
for operator console1
for signaling contact1
for power supply1
for redundant voltage supply1
Type of electrical connection
for operator consoleRJ11
for signaling contact2-pole terminal block
for power supply4-pole terminal block
design of the removable storage
C-PLUGYes
Signal-Inputs/outputs
Operating voltage / of the signaling contacts
at DC / Rated value24 V
Operating current / of the signaling contacts
at DC / maximum0.1 A
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltageDC
Supply voltage
external24 V
external / minimum9.6 V
external / maximum31.2 V
Supply voltage / 4 / Rated value
Consumed current / 4 / at rated supply voltage / maximum0.275 A
Product component / fusing at power supply inputYes
Fuse protection type / at input for supply voltage2.5 A / 125 V
Consumed current / maximum0.55 A
Power loss [W]
at DC / at 24 V6.6 W
Permitted ambient conditions
Ambient temperature
during operation-40 ... +70 °C
during storage-40 ... +85 °C
during transport-40 ... +85 °C
Relative humidity
at 25 °C / without condensation / during operation / maximum95 %
Protection class IPIP20
Design, dimensions and weight
Designcompact
Width120 mm
Height147 mm
Depth125 mm
Net weight0.8 kg
Material / of the enclosurePolycarbonate (PC-GF10) / pressure die cast aluminum
Mounting type
35 mm DIN rail mountingYes
wall mountingYes
S7-300 rail mountingYes
S7-1500 rail mountingYes
Product properties, functions, components / general
Cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s50
Cascading in cases of star topologyany (depending only on signal propagation time)
Product function / QoS according to DSCPYes
Product feature
Cut Through switching methodNo
Store & Forward switching methodYes
Product functions / management, configuration
Product function
CLIYes
web-based managementYes
MIB supportYes
TRAPs via emailYes
Configuration with STEP 7Yes
RMONYes
SMTP serverNo
Port mirroringYes
multiport mirroringYes
CoSYes
PROFINET IO diagnosisYes
PROFINET conformity classB
Product function / switch-managedYes
Telegram length / for Ethernet / maximum1632 byte
Protocol / is supported
TelnetYes
HTTPYes
HTTPSYes
TFTPYes
BOOTPNo
GMRPYes
DCPYes
LLDPYes
EtherNet/IPYes
SNMP v1Yes
SNMP v2Yes
SNMP v3Yes
IGMP (snooping/querier)Yes
Identification & maintenance function
I&M0 - device-specific informationYes
I&M1 – higher-level designation/location designationYes
Product functions / Diagnosis
Product function
Port diagnosticsYes
Statistics Packet SizeYes
Statistics packet typeYes
Error statisticsYes
SysLogYes
Product functions / VLAN
Product function
VLAN - port basedYes
VLAN - protocol-basedNo
VLAN - IP-basedNo
Number of VLANs / maximum257
Number of VLANs - dynamic / maximum257
Protocol / is supported / GVRPYes
Product functions / DHCP
Product function
DHCP serverYes
DHCP clientYes
DHCP Option 82Yes
DHCP Option 66Yes
DHCP Option 67Yes
Product functions / Redundancy
Product function
of the PROFINET IO device / is supported / PROFINET system redundancy (S2)Yes
Ring redundancyYes
High Speed Redundancy Protocol (HRP)Yes
high speed redundancy protocol (HRP) with redundancy managerYes
high speed redundancy protocol (HRP) with standby redundancyYes
Protocol / is supported / Media Redundancy Protocol (MRP)Yes
Product function
media redundancy protocol (MRP) with redundancy managerYes
redundancy procedure STPYes
redundancy procedure RSTPYes
redundancy procedure MSTPYes
Parallel Redundancy Protocol (PRP)/operation in the PRP-networkYes
Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)No
Passive listeningYes
Protocol / is supported
LACPYes
Product functions / Security
Product function
IEEE 802.1x (radius)Yes
Broadcast/Multicast/Unicast LimiterYes
broadcast blockingYes
Protocol / is supported
SSHYes
SSLYes
Product functions / Time
Product function
SICLOCK supportYes
NTP-clientYes
SNTP clientYes
Protocol / is supported
NTPYes
SNTPYes
Standards, specifications, approvals / CE
Certificate of suitability / CE markingYes
Product conformity / according to EMC-guideline2014/30/EU
Standard
for EMC interference emissionEN 61000-6-4, EN 50121-4
for immunity to EMIEN 61000-6-2, EN 50121-4
Certificate of suitability / RoHS conformityYes; 2011/65/EU
Standards, specifications, approvals / hazardous environments
Certificate of suitability
ATEXYes; EN 60079-0, EN 60079-15
for ATEX / as markingII 3 G Ex nA II T4 Gc
for ATEX / as certificateKEMA 07ATEX0145 X
IECExYes; IEC 60079-0, IEC 60079-15
for IECEx / as markingEx nA II T4 Gc
for IECEx / as certificateIECEx DEK 14.0025X
for cULus HazLoc / as markingCL1, DIV2, Group A,B,C,D T4, CL1, Zone 2, Group IIC, T4
for cULus HazLoc / as File Nr.E240480 (NWHP, NWHP7)
FM registrationYes; FM class 3600:2011, FM class 3611:2004, FM class 3810:2005, ANSI/ISA-61010-1:2004
for FM / as markingCL1, DIV2, group A,B,C,D T4, CL1, Zone 2, group IIC, T4 Ta: -40 °C … +70 °C
for FM / as certificateFM16US0205X
Standards, specifications, approvals / miscellaneous
Certificate of suitability
Railway application in accordance with EN 50121-4Yes
Regulatory Compliance Mark (RCM)Yes
for UL 61010-2-201 / as File Nr.E85972 (NRAQ, NRAQ7)
for UL 60950-1 / as File Nr.E115352 (NWGQ, NWGQ7)
EAC approvalYes
Standards, specifications, approvals / ship classification
Marine classification association
American Bureau of Shipping Europe Ltd. (ABS)Yes
Bureau Veritas (BV)Yes
DNV GLYes
Korean Register of Shipping (KRS)Yes
Lloyds Register of Shipping (LRS)Yes
Nippon Kaiji Kyokai (NK)Yes
Polski Rejestr Statkow (PRS)Yes
Royal Institution of Naval Architects (RINA)Yes
Standards, specifications, approvals / product conformity
MTBF48 y
Accessories
Product extension / optional / C-PLUGYes

External links