| SCALANCE X116, Unmanaged IE switch, 16x 10/100 Mbit/s RJ45 ports, LED diagnostics, error-signaling contact with set button, redundant Power supply Manual available as a download |
Product type designation | SCALANCE X116 |
Transmission rate |
Transfer rate | 10 Mbit/s, 100 Mbit/s |
Interfaces / for communication / integrated |
Number of electrical connections | |
for network components or terminal equipment | 16; RJ45 with securing collar |
Number of 100 Mbit/s SC ports | |
for multimode | 0 |
Interfaces / others |
Number of electrical connections | |
for signaling contact | 1 |
for power supply | 1 |
for redundant voltage supply | 1 |
Type of electrical connection | |
for signaling contact | 2-pole terminal block |
for power supply | 4-pole terminal block |
Signal-Inputs/outputs |
Operating voltage / of the signaling contacts | |
at DC / Rated value | 24 V |
Operating current / of the signaling contacts | |
at DC / maximum | 0.1 A |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Supply voltage | |
external | 24 V |
external / minimum | 18 V |
external / maximum | 32 V |
Product component / fusing at power supply input | No |
Consumed current / maximum | 0.3 A |
Power loss [W] | |
at DC / at 24 V | 4.4 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | -20 ... +70 °C |
during storage | -40 ... +80 °C |
during transport | -40 ... +80 °C |
Relative humidity | |
at 25 °C / without condensation / during operation / maximum | 95 % |
Protection class IP | IP30 |
Design, dimensions and weight |
Design | compact |
Width | 120 mm |
Height | 125 mm |
Depth | 124 mm |
Net weight | 1.1 kg |
Mounting type | |
35 mm DIN rail mounting | Yes |
wall mounting | Yes |
S7-300 rail mounting | Yes |
S7-1500 rail mounting | No |
Product functions / management, configuration |
Product function | |
multiport mirroring | No |
CoS | Yes |
Product function / switch-managed | No |
Product functions / Redundancy |
Product function | |
Parallel Redundancy Protocol (PRP)/operation in the PRP-network | Yes |
Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA) | No |
Standards, specifications, approvals |
Standard | |
for FM | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
for hazardous zone | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X |
for safety / from CSA and UL | UL 60950-1, CSA C22.2 No. 60950-1 |
for hazardous zone / from CSA and UL | UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
for emitted interference | EN 61000-6-4:2001 |
for interference immunity | EN 61000-6-2:2001 |
Standards, specifications, approvals / CE |
Certificate of suitability / CE marking | Yes |
Standards, specifications, approvals / miscellaneous |
Certificate of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 |
C-Tick | Yes |
KC approval | Yes |
Standards, specifications, approvals / ship classification |
Marine classification association | |
American Bureau of Shipping Europe Ltd. (ABS) | Yes |
Bureau Veritas (BV) | Yes |
Det Norske Veritas (DNV) | Yes |
Germanische Lloyd (GL) | No |
Lloyds Register of Shipping (LRS) | Yes |
Nippon Kaiji Kyokai (NK) | Yes |
Polski Rejestr Statkow (PRS) | Yes |
Royal Institution of Naval Architects (RINA) | Yes |
Standards, specifications, approvals / product conformity |
MTBF | 61.3 y |