Product type designation | CP 5613 FO |
| Communications processor CP 5613 FO, PCI card (32 bit) for connection to opt. PB incl. DP base software with NCM PC; DP-RAM interface for DP master incl. PG and FDL protocol, Single license for 1 installation, runtime software, software and electr. manual on CD-ROM, Class A, 2 languages (de, en), Operating system support see SIMATIC NET software |
Transmission rate |
Transfer rate | |
at the 1st interface / acc. to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s |
Interfaces |
Number of electrical connections | |
for power supply | 1 |
Number of optical interfaces / at the 1st interface / acc. to PROFIBUS | 2 |
Type of electrical connection | |
for power supply | Low-voltage socket for hollow plug 3.5 mm (-) / 1.3 mm (+) |
Design of the optical interface / at the 1st interface / acc. to PROFIBUS | 2 x duplex socket (FO) |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Type of voltage supply / optional external supply | Yes |
Supply voltage | |
1 / from backplane bus | 5 V |
2 / from backplane bus | 12 V |
external | 9 ... 12 V |
Relative symmetrical tolerance / at DC | |
at 5 V | 5 % |
at 12 V | 5 % |
Consumed current | |
1 / from backplane bus / at DC / maximum | 1.4 A |
2 / from backplane bus / at DC / maximum | 0.3 A |
from external supply voltage / at DC / at 12 V / maximum | 0.4 A |
Power loss [W] | 7 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | 0 ... 60 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 80 % |
Protection class IP | IP00 |
Design, dimensions and weight |
Module format | PCI |
Width | 18 mm |
Height | 107 mm |
Depth | 168 mm |
Net weight | 120 g |
Number of plug-in cards of same design / plug-in / per PC station | 4 |
Number of units / Note | - |
Wire length | |
for POF FOC / maximum | 50 m |
Performance data |
Performance data / open communication |
Software / for open communication / by means of SEND/RECEIVE / required | FDL driver included in scope of delivery of the CP |
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum | 80 |
Performance data / PROFIBUS DP |
Software / for DP master function / required | No |
Service / as DP master | |
DPV0 | Yes |
DPV1 | Yes |
DPV2 | Yes |
Number of DP slaves / on DP master / usable | 124 |
Amount of data | |
of the address area of the inputs / as DP master / total | 30256 byte |
of the address area of the outputs / as DP master / total | 30256 byte |
of the address area of the inputs / per DP slave | 244 byte |
of the address area of the outputs / per DP slave | 244 byte |
of the address area of the diagnostic data / per DP slave | 244 byte |
Service / as DP slave | |
DPV0 | No |
DPV1 | No |
Performance data / FMS functions |
Software / for FMS communication / required | Yes, FMS-5613 |
Number of possible connections / for FMS connection / maximum | 40 |
Performance data / S7 communication |
Software / for S7 communication / required | Yes, HARDNET-PB S7 (S7-5613) |
Number of possible connections / for S7/PG communication / maximum | 50 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode | 50 |
Number of configurable connections / per PC station | 207 |
Product functions / management, configuration |
Configuration software / required | Included in scope of supply |
Product functions / Diagnosis |
Product function | |
Port diagnostics | Yes |
Standards, specifications, approvals |
Standard | |
for EMC | 2004/108/EC |
for safety / from CSA and UL | CAN/CSA C22.2 & UL 60950-1, UL 1950 |
for emitted interference | EN 50081-1, EN 50081-2 |
for interference immunity | EN 50082-1, EN 50082-2 |
Certificate of suitability | |
CE marking | Yes |
C-Tick | Yes |