Product type designation | CP 5613 A2 |
| Communications processor CP 5613 A2, PCI card to connection to PROFIBUS; incl. DP-Base software, Configuring tool: DP-RAM Interface for DP master incl. PG and FDL protocol, Single License for 1 installation, Runtime software, Class A; software and electr. manual on CD-ROM, 2 languages (de,en); Operating system support see SIMATIC NET Software; only for old applications, Wwindows XP and higher 6GK1561-3AA02 is recommended, see http:/support.automation. siemens.com/ WW/view/DE/22611503 |
Transmission rate |
Transfer rate | |
at the 1st interface / acc. to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s |
Interfaces |
Number of electrical connections | |
at the 1st interface / acc. to PROFIBUS | 1 |
Type of electrical connection | |
at the 1st interface / acc. to PROFIBUS | 9-pin Sub-D socket (RS 485) |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Supply voltage | |
1 / from backplane bus | 5 V |
Relative symmetrical tolerance / at DC | |
at 5 V | 5 % |
Consumed current | |
1 / from backplane bus / at DC / maximum | 0.8 A |
Power loss [W] | 4 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | 5 ... 50 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 85 % |
Protection class IP | IP00 |
Design, dimensions and weight |
Module format | PCI |
Width | 18 mm |
Height | 107 mm |
Depth | 168 mm |
Net weight | 100 g |
Number of plug-in cards of same design / plug-in / per PC station | 4 |
Number of units / Note | FMS-5613 supports up to two CP 5603 / CP 5613 A2 / CP 5614 A2 / CP 5623 / CP 5624 processors |
Performance data |
Performance data / open communication |
Software / for open communication / by means of SEND/RECEIVE / required | FDL driver included in scope of delivery of the CP |
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum | 80 |
Performance data / PROFIBUS DP |
Software / for DP master function / required | No |
Service / as DP master | |
DPV0 | Yes |
DPV1 | Yes |
DPV2 | Yes |
Number of DP slaves / on DP master / usable | 124 |
Amount of data | |
of the address area of the inputs / as DP master / total | 30256 byte |
of the address area of the outputs / as DP master / total | 30256 byte |
of the address area of the inputs / per DP slave | 244 byte |
of the address area of the outputs / per DP slave | 244 byte |
of the address area of the diagnostic data / per DP slave | 244 byte |
Software / for DP slave function / required | No |
Service / as DP slave | |
DPV0 | Yes |
DPV1 | Yes |
Amount of data | |
of the address area of the inputs / as DP slave / total | 244 byte |
of the address area of the outputs / as DP slave / total | 244 byte |
Performance data / FMS functions |
Software / for FMS communication / required | Yes, FMS-5613 |
Number of possible connections / for FMS connection / maximum | 40 |
Performance data / S7 communication |
Software / for S7 communication / required | Yes, HARDNET-PB S7 (S7-5613) |
Number of possible connections / for S7/PG communication / maximum | 50 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode | 50 |
Number of configurable connections / per PC station | 207 |
Product functions / management, configuration |
Configuration software / required | Included in scope of supply |
Product functions / Diagnosis |
Product function | |
Port diagnostics | Yes |
Standards, specifications, approvals |
Standard | |
for EMC | 89/336/EEC |
for safety / from CSA and UL | CAN/CSA C22.2 & UL 60950-1, UL 1950 |
for emitted interference | EN 50081-1, EN 50081-2 |
for interference immunity | EN 50082-1, EN 50082-2 |
Certificate of suitability | |
CE marking | Yes |
C-Tick | Yes |