Product type designation | IE/PB-Link PN IO |
| IE/PB LINK PN IO gateway between Ind. Ethernet and PROFIBUS with PROFINET IO Functionality S7 routing and dataset routing, 10/100 Mbit/s Fast Ethernet 9.6 Kbit/s up to 12 Mbit/s PROFIBUS Functional replacement for this product is 6GK1411-5AB10, Please not: Changed enclosure dimensions |
Transmission rate |
Transfer rate | |
at the 1st interface | 10 ... 100 Mbit/s |
at the 1st interface / acc. to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s |
Interfaces |
Number of interfaces / acc. to Industrial Ethernet | 1 |
Number of electrical connections | |
at the 1st interface / acc. to Industrial Ethernet | 1 |
at the 1st interface / acc. to PROFIBUS | 1 |
for power supply | 1 |
Type of electrical connection | |
at the 1st interface / acc. to PROFIBUS | 9-pin Sub-D socket (RS485) |
at the 1st interface / acc. to Industrial Ethernet | RJ45 port |
for power supply | 2-pole terminal block |
design of the removable storage / C-PLUG | Yes |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Supply voltage / external | 24 V |
Supply voltage / external / at DC / Rated value | 24 V |
Relative positive tolerance / at DC / at 24 V | 5 % |
Relative negative tolerance / at DC / at 24 V | 5 % |
Consumed current | |
from external supply voltage / at DC / at 24 V / maximum | 0.6 A |
Power loss [W] | 10 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | 0 ... 60 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight |
Module format | Compact module S7-300 double width |
Width | 80 mm |
Height | 125 mm |
Depth | 120 mm |
Net weight | 0.6 kg |
Performance data / PROFIBUS DP |
Service / as DP master | |
DPV1 | Yes |
Number of DP slaves / on DP master / usable | 64 |
Amount of data | |
of the address area of the inputs / as DP master / total | 2048 byte |
of the address area of the outputs / as DP master / total | 2048 byte |
of the address area of the inputs / per DP slave | 244 byte |
of the address area of the outputs / per DP slave | 244 byte |
Performance data / S7 communication |
Number of possible connections / for S7 communication | |
maximum | 32 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode | 48 |
Performance data / PROFINET communication / as PN IO-Device |
Product function / PROFINET IO device | Yes |
Performance data / telecontrol |
Protocol / is supported | |
TCP/IP | Yes |
Product functions / management, configuration |
Product function / MIB support | Yes |
Protocol / is supported | |
SNMP v1 | Yes |
Configuration software | |
required | STEP 7 V5.4 or higher or STEP 7 Professional (TIA Portal) V11 or higher |
Product functions / Routing |
Service / as PROFIBUS / dataset routing | Yes; Maximum 32 connections |
Number of possible connections / with dataset routing / maximum | 32 |
Product functions / Time |
Product function / pass on time synchronization | Yes |