Product type designation | CP 1612 A2 |
| Communications processor CP 1612 A2 PCI card (32 bit; 3.3/5 V universal keyed) to Connection to Industrial Ethernet (10/100/1000 Mbit/s) with RJ45 connection via SOFTNET S7 and SOFTNET PG Operating system support see SIMATIC NET software released as of SIMATIC NET CD 2008 SP2 |
Transmission rate |
Transfer rate | 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s |
Interfaces |
Number of electrical connections | |
at the 1st interface / acc. to Industrial Ethernet | 1 |
Type of electrical connection | |
at the 1st interface / acc. to Industrial Ethernet | RJ45 port |
Supply voltage, current consumption, power loss |
Type of voltage / of the supply voltage | DC |
Supply voltage | |
1 / from backplane bus | 5 V |
2 / from backplane bus | 12 V |
Relative symmetrical tolerance / at DC | |
at 5 V | 5 % |
at 12 V | 5 % |
Consumed current | |
1 / from backplane bus / at DC / maximum | 0.45 A |
2 / from backplane bus / at DC / maximum | 0.5 A |
Power loss [W] | 3.65 W |
Permitted ambient conditions |
Ambient temperature | |
during operation | 0 ... 55 °C |
during storage | -10 ... +70 °C |
during transport | -10 ... +70 °C |
Relative humidity / at 25 °C / without condensation / during operation / maximum | 95 % |
Protection class IP | IP00 |
Design, dimensions and weight |
Module format | PCI |
Width | 18 mm |
Height | 59 mm |
Depth | 140 mm |
Net weight | 60 g |
Number of plug-in cards of same design / plug-in / per PC station | 2 |
Number of units / Note | - |
Performance data |
Performance data / open communication |
Software / for open communication / by means of SEND/RECEIVE / required | Yes, SOFTNET-IE S7 (64 conn.) / SOFTNET-IE S7 Lean (8 conn.) |
Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum | 64 |
Performance data / S7 communication |
Software / for S7 communication / required | Yes, SOFTNET-IE S7 (64 conn.) / SOFTNET-IE S7 Lean (8 conn.) |
Number of possible connections / for S7/PG communication / maximum | 64 |
Performance data / multi-protocol mode |
Number of active connections / with multi-protocol mode | 64 |
Number of configurable connections / per PC station | 207 |
Performance data / PROFINET communication / as PN IO-Controller |
Software / for PROFINET IO communication / required | Yes, SOFTNET-IE PN IO |
Number of PN IO devices / on PROFINET IO controller / usable / total | 64 |
Number of PN IO IRT devices / on PROFINET IO controller / usable | 0 |
Amount of data | |
as user data for input variables / as PROFINET IO controller / maximum | 4096 byte |
as user data for input variables / as PROFINET IO controller / maximum | 4096 byte |
as user data for input variables per PN IO device / as PROFINET IO controller / maximum | 1430 byte |
as user data for output variables per PN IO device / as PROFINET IO controller / maximum | 1430 byte |
Performance data / PROFINET CBA |
Software / for PROFINET CBA communication / required | Yes, PN CBA OPC server |
Number of remote connection partners / with PROFINET CBA | 228 |
Number of connections / with PROFINET CBA / total | 10000 |
Product functions / management, configuration |
Product function / MIB support | No |
Protocol / is supported | |
SNMP v1 | Yes |
SNMP v3 | No |
DCP | Yes |
LLDP | Yes |
Configuration software / required | Included in the scope of delivery of the required software product |
Configuration software / for PROFINET CBA / required | Yes, SIMATIC iMAP |
Identification & maintenance function | |
I&M0 - device-specific information | Yes |
I&M1 – higher-level designation/location designation | Yes |
I&M2 - installation date | No |
I&M3 - comment | No |
I&M4 - signature | No |
I&M4 - OEM data | No |
Standards, specifications, approvals |
Standard | |
for EMC | 2004/108/EC |
for safety / from CSA and UL | CAN/CSA C22.2 & UL 60950-1, UL 1950 |
for emitted interference | EN 61000-6-3, EN 61000-6-4 |
for interference immunity | EN 61000-6-1, EN 61000-6-2 |
Certificate of suitability | |
CE marking | Yes |
C-Tick | Yes |