6ES7672-5DC01-0YA0
SIMATIC Software Controller CPU 1505SP

From SIEMENS

SIMATIC S7-1500 Software Controller CPU 1505SP Version 2.1, Single license for 1 installation, R-SW, Class A, 6 languages (de,en,it,fr,es,zh), pre-installed on ET 200SP Open Controller
General information
Product type designationCPU 1505SP
Software versionV2.1
Engineering with
STEP 7 TIA Portal configurable/integrated as of versionV14 SP1
Configuration control
via datasetYes
Memory
SIMATIC memory card requiredNo; Use of the PC mass storage
Work memory
integrated (for program)1 Mbyte
integrated (for data)5 Mbyte
integrated (for CPU function library of CPU Runtime)10 Mbyte
Load memory
integrated (on PC mass storage)320 Mbyte
Backup
with UPSYes; all memory areas declared retentive
with non-volatile memoryYes
CPU processing times
for bit operations, typ.10 ns
for word operations, typ.12 ns
for fixed point arithmetic, typ.16 ns
for floating point arithmetic, typ.64 ns
CPU-blocks
Number of elements (total)6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements
DB
Number, max.5 999; Number range: 1 to 65535
Size, max.5 Mbyte
FB
Number, max.5 998; Number range: 1 to 65535
Size, max.512 kbyte
FC
Number, max.5 999; Number range: 1 to 65535
Size, max.512 kbyte
OB
Size, max.512 kbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs1
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Nesting depth
per priority class24
Counters, timers and their retentivity
S7 counter
Number2 048
Retentivity
— adjustableYes
IEC counter
NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 times
Number2 048
Retentivity
— adjustableYes
IEC timer
NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.410 kbyte; On CPU 1515SP PC; can be used for bit memories, timers, counters, DBs and technology data (axes); 5 242 020 bytes when saving to mass memory
Flag
Number, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
Retentivity adjustableYes
Retentivity presetNo
Address area
Number of IO modules8 192
I/O address area
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
Subprocess images
Number of subprocess images, max.32
Hardware configuration
Number of distributed IO systems20
Number of DP masters
Via CM1
Number of IO Controllers
via PC interfaces1
Rack
Modules per rack, max.64; CPU 1515SP PC + 64 modules + server module
PtP CM
Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
TypeSoftware clock, synchronizable, no battery backup
Deviation per day, max.Depending on PC hardware
Clock synchronization
supportedYes
on Windows clock, slaveYes
Interfaces
Number of interfaces2
Number of PROFINET interfaces1
Number of PROFIBUS interfaces1
1. Interface
Interface typeOnboard PROFINET interface of the CPU 1515SP PC
Number of connections88
Interface types
Number of ports2
integrated switchYes
RJ 45 (Ethernet)
— Transmission rate, max.100 Mbit/s
— Industrial Ethernet status LEDYes
BusAdapter (PROFINET)Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC
Protocols
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes
Web serverYes
Media redundancyYes
PROFINET IO Controller
Services
— Isochronous modeYes
— shortest clock pulse500 µs
— IRTYes
— MRPYes
— MRPDYes
— PROFIenergyYes
— Prioritized startupYes; Max. 32 PROFINET devices; if you want to use the "Prioritized startup" functionality in STEP 7 for the PROFINET interface of the CPU, the CPU and the device must be separated by means of a switch (e.g. SCALANCE X205)
— Number of connectable IO Devices, max.128
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.128
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 500 µs500 µs to 8 ms
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
PROFINET IO Device
Services
— Isochronous modeNo
— shortest clock pulse500 µs
— IRTYes
— MRPYes
— MRPDYes
— PROFIenergyYes
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
3. Interface
Interface typePROFIBUS with CM DP
Number of connections via this interface44
Interface types
RS 485Yes
Protocols
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
SIMATIC communicationYes
PROFIBUS DP master
Number of DP slaves, max.125
Services
— EquidistanceNo
— Isochronous modeNo
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
PROFIBUS DP slave
Services
— EquidistanceNo
— Isochronous modeNo
Protocols
Number of connections
Number of connections, max.88
Number of connections reserved for ES/HMI/web10
Number of S7 routing paths16
SIMATIC communication
PG/OP communicationYes
S7 routingYes
S7 communication, as serverYes
S7 communication, as clientYes
User data per job, max.64 kbyte; BSEND/BRCV: 64 KB; PUT/GET: 960 bytes
Open IE communication
TCP/IPYes
— Data length, max.64 kbyte
ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
UDPYes
— Data length, max.1 472 kbyte
SNMPYes
DCPYes
LLDPYes
Web server
HTTPYes; Via Windows and PROFINET interface
HTTPSYes; Via Windows and PROFINET interface
OPC UA
OPC UA clientNo
OPC UA serverYes; Data access (read, write, subscribe), runtime license required
— Application authenticationYes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— Security policiesYes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authenticationYes; "anonymous" or by user name & password
Further protocols
MODBUSYes; MODBUS TCP
Media redundancy
Switchover time on line break, typ.200 ms
Number of stations in the ring, max.50
S7 message functions
Number of login stations for message functions, max.32
Program alarmsYes
Number of configurable program messages, max.10 000
Number of simultaneously active program alarms
Number of program alarms1 000
Number of alarms for system diagnostics200
Number of alarms for motion technology objects160
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 8 engineering systems
Status blockYes; up to 8 simultaneously
Single stepNo
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.
— of which status variables, max.200
— of which control variables, max.200
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.200
Diagnostic buffer
presentYes
Number of entries, max.1 000
— of which powerfail-proof300
Traces
Number of configurable Traces4
Memory size per trace, max.512 kbyte
Interrupts/diagnostics/status information
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
Supported technology objects
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER
Number of available Motion Control resources for technology objects (except cam disks)2 400
Required Motion Control resources
— per speed-controlled axis40; per axis
— per positioning axis80; per axis
— per synchronous axis160; per axis
— per external encoder80; per external encoder
— per output cam20; per cam
— per cam track160; per cam track
— per probe40; per probe
Positioning axis
— Number of positioning axes at motion control cycle of 4 ms (typical value)15; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz
— Number of positioning axes at motion control cycle of 8 ms (typical value)30; on SIMATIC IPC427D, Intel Core i7 processor, 1.7 GHz
Controller
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
High-speed counterYes
Hardware requirement
Hardware requiredCPU 1515SP PC
Processor
Single-core processorNo
Single-core processor with hyper-threadingNo
Multi-core processorYes
occupied cores1
Memory
Work memory, min.4 Gbyte
Hard disk memory required for installation720 Mbyte
Temporary hard disk memory for installation230 Mbyte
Hard disk memory required at runtime400 Mbyte
Operating systems
pre-installed operating system
Windows Embedded Standard 7Yes; Delivery image of the CPU 1515SP PC
Configuration
Programming
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCNo
— GRAPHYes
Know-how protection
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
Access protection
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Complete protectionYes
Cycle time monitoring
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Open Development interfaces
Size of ODK SO file, max.3.8 Mbyte
last modified:02/21/2020