6ES7671-7EG00-0YA0
WINAC MP 2007 /MP 377

From SIEMENS

SIMATIC WINAC MP 2007 SOFTWARE SPS FOR MP377 PLATFORMS INCL. SINGLE LICENSE ON USB STICK INCL. ELECTRONIC DOCU
General information
Engineering with
Programming packageFrom WinAC MP 2007 and WinCC flexible 2007 and STEP 7 V5.4 SP1
Memory
Work memory
integrated512 kbyte
expandableNo
Load memory
integrated RAM, max.1.2 Mbyte
CPU-blocks
DB
Number, max.2 048; FBs+FCs+DBs=2048
Size, max.64 kbyte
FB
Number, max.2 048; FBs+FCs+DBs=2048
Size, max.64 kbyte
FC
Number, max.2 048; * max. 2048 total
Size, max.64 kbyte
OB
Number, max.18
Size, max.64 kbyte
Number of free cycle OBs1
Number of time alarm OBs1
Number of delay alarm OBs1
Number of cyclic interrupt OBs1
Number of process alarm OBs1
Number of startup OBs2
Number of asynchronous error OBs6
Nesting depth
per priority class16
additional within an error OB2
Counters, timers and their retentivity
S7 counter
Number512
Retentivity
— adjustableYes
— lower limit0
— upper limit512
— preset8
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes; SFB0, SFB1, SFB2
S7 times
Number512
Retentivity
— adjustableYes
— lower limit0
— upper limit512
— preset0
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes; SFB3, SFB4, SFB5
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.256 kbyte
Flag
Number, max.4 kbyte
Retentivity availableYes
Data blocks
Retentivity adjustableYes
Local data
per priority class, max.16 384 byte; Max. for all priority classes
Address area
I/O address area
Inputs8 kbyte
Outputs8 kbyte
of which distributed
— Inputs8 kbyte
— Outputs8 kbyte
Process image
Inputs2 kbyte
Outputs2 kbyte
Inputs, adjustable2 kbyte
Outputs, adjustable2 kbyte
Inputs, default512 byte
Outputs, default512 byte
consistent data, max.32 byte
Hardware configuration
Number of DP masters
integrated1
Time of day
Operating hours counter
Number8
Number/Number range0 to 7
1. Interface
PROFIBUS DP master
Number of connections, max.8
Transmission rate, max.12 000 kbit/s
Number of DP slaves, max.32
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— EquidistanceNo
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— DPV1Yes
Address area
— Inputs, max.8.192 kbyte
— Outputs, max.8.192 kbyte
User data per DP slave
— User data per DP slave, max.244 byte; Max. consistent user data length 32 bytes
Communication functions
S7 communication
as serverYes
as clientYes
User data per job, max.0.48 kbyte
Number of connections
overall32; max. 8 DP, rest PROFINET
— of which static30; max. 6 DP, rest PROFINET
usable for PG communication
— reserved for PG communication1
usable for OP communication
— reserved for OP communication1
usable for routing16
Number of logical connections (also in network), max.32
S7 message functions
Process diagnostic messagesYes
Test commissioning functions
Status/control
Status/control variableYes; Status blocks, single step, breakpoint
Forcing
ForcingNo
Diagnostic buffer
presentYes
Number of entries, max.1 000; preset 120
— adjustableYes
Operating systems
pre-installed operating system
Windows CEYes
Configuration
Configuration software
STEP 7Yes
WinCC flexible CompactNo
WinCC flexible StandardYes
WinCC flexible AdvancedYes
Programming
Programming language
— LADYes
— FBDYes
— STLYes
Cycle time monitoring
adjustableYes
preset6 000 ms
Languages
Online languages
Number of online/runtime languages1; English