6ES7318-3EL00-0AB0
CPU319-3 PN/DP, 1.4MB

From SIEMENS

***Spare part*** SIMATIC S7-300 CPU 319-3 PN/DP, Central processing unit with 1.4MB memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP master/slave 3rd interface Ethernet PROFINET, Micro Memory Card required
General information
HW functional status09
Firmware versionV2.8
Engineering with
Programming packageSTEP 7 V5.4 + SP5 or higher or STEP 7 V5.4 + SP4 or higher with HSP 186
Supply voltage
Rated value (DC)
24 V DCYes
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Input current
Current consumption (rated value)1 050 mA
Current consumption (in no-load operation), typ.400 mA
Inrush current, typ.4 A
I²t1.2 A²·s
Power loss
Power loss, typ.14 W
Memory
Work memory
integrated1 400 kbyte
expandableNo
Size of retentive memory for retentive data blocks700 kbyte
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 y
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
for bit operations, typ.0.01 µs
for word operations, typ.0.02 µs
for fixed point arithmetic, typ.0.02 µs
for floating point arithmetic, typ.0.04 µs
CPU-blocks
Number of blocks (total)4 096; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.4 096; Number range: 1 to 16000
Size, max.64 kbyte
FB
Number, max.4 096; Number range: 0 to 7999
Size, max.64 kbyte
FC
Number, max.4 096; Number range: 0 to 7999
Size, max.64 kbyte
OB
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs4; OB 32, 33, 34, 35 (OB 35: smallest settable clock pulse = 500 µs)
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number of isochronous mode OBs1; OB 61
Number of startup OBs1; OB 100
Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetZ 0 to Z 7
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in totalAll, max. 700 KB
Flag
Number, max.8 192 byte
Retentivity availableYes; From MB 0 to MB 8 191
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.32 768 byte; Max. 2048 bytes per block
Address area
I/O address area
Inputs8 192 byte
Outputs8 192 byte
of which distributed
— Inputs8 192 byte
— Outputs8 192 byte
Process image
Inputs8 192 byte
Outputs8 192 byte
Inputs, adjustable8 192 byte
Outputs, adjustable8 192 byte
Inputs, default256 byte
Outputs, default256 byte
Subprocess images
Number of subprocess images, max.1
Digital channels
Inputs65 536
— of which central1 024
Outputs65 536
— of which central1 024
Analog channels
Inputs4 096
— of which central256
Outputs4 096
— of which central256
Hardware configuration
Number of expansion units, max.3
Number of DP masters
integrated2
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, PtP8
CP, LAN10
Rack
Racks, max.4
Modules per rack, max.8
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s
Behavior of the clock following expiry of backup periodClock continues to run with the time at which the power failure occurred
Operating hours counter
Number4
Number/Number range0 to 3
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes; With DP slave only slave clock
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
on Ethernet via NTPYes; As client
Digital inputs
integrated channels (DI)0
Digital outputs
integrated channels (DO)0
Analog inputs
integrated channels (AI)0
Analog outputs
integrated channels (AO)0
Interfaces
Number of industrial Ethernet interfaces1
Number of PROFINET interfaces1
Number of RS 485 interfaces2
Number of RS 422 interfaces0
1. Interface
Interface typeIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.150 mA
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
Point-to-point connectionNo
MPI
Number of connections32
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeNo
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Number of DP slaves that can be simultaneously activated/deactivated, max.8
— Direct data exchange (slave-to-slave communication)Yes; As subscriber
— DPV1Yes
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP slave
Transmission rate, max.12 Mbit/s
automatic baud rate searchYes; only with passive interface
Address area, max.32
User data per address area, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes; with interface active
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication)Yes
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
Interface typeIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Protocols
MPINo
PROFINET IO ControllerNo
PROFINET IO DeviceNo
PROFINET CBANo
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
Open IE communicationNo
Web serverNo
Point-to-point connectionNo
PROFIBUS DP master
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes; Connection configured on one side only
— EquidistanceYes
— Isochronous modeYes; OB 61
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Number of DP slaves that can be simultaneously activated/deactivated, max.8
— Direct data exchange (slave-to-slave communication)Yes; As subscriber
— DPV1Yes
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
PROFIBUS DP slave
GSD fileThe latest GSD file is available at: http://www.siemens.com/profibus-gsd
Transmission rate, max.12 Mbit/s
automatic baud rate searchYes; only with passive interface
Address area, max.32
User data per address area, max.32 byte
Services
— PG/OP communicationYes
— RoutingYes; with interface active
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication)Yes
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
3. Interface
Interface typePROFINET
PhysicsEthernet RJ45
IsolatedYes
automatic detection of transmission rateYes; 10/100 Mbit/s
AutonegotiationYes
AutocrossingYes
Interface types
Number of ports1
integrated switchNo
Protocols
MPINo
PROFINET IO ControllerYes
PROFINET IO DeviceNo
PROFINET CBAYes
PROFIBUS DP masterNo
PROFIBUS DP slaveNo
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Web serverYes; only read function
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— S7 communicationYes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
— Isochronous modeNo
— Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.32
— Number of connectable IO Devices, max.256
— Number of IO Devices with IRT and the option "high flexibility"256
— of which in line, max.61
— Number of connectable IO Devices for RT, max.256
— of which in line, max.256
— Activation/deactivation of IO DevicesYes
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8
— Device replacement without swap mediumYes
— Send cycles250 µs, 500 µs, 1 ms
— Updating time250 µs - 128 ms (with send cycle of 250 µs); 500 µs - 256 ms (with send cycle of 500 µs); 1 ms - 512 ms (with send cycle 1 ms); minimum value of the send cycle is also dependent on the set communication share for PROFINET IO, on the number of I/O devices, and on the volume of configured user data.
Address area
— Inputs, max.8 kbyte
— Outputs, max.8 kbyte
— User data consistency, max.254 byte
PROFINET CBA
acyclic transmissionYes
cyclic transmissionYes
Open IE communication
Number of connections, max.32
Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Protocols
Open IE communication
TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.32
— Data length for connection type 01H, max.1 460 byte
— Data length for connection type 11H, max.8 192 byte
ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.32
— Data length, max.8 192 byte
UDPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.32
— Data length, max.1 472 byte
Web server
supportedYes; only read function
Number of HTTP clients5
Isochronous mode
Isochronous operation (application synchronized up to terminal)Yes; Via 2nd DP interface
Communication functions
PG/OP communicationYes
Data record routingYes
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
supportedYes; via CP and loadable FC
PROFINET CBA (at set setpoint communication load)
Setpoint for the CPU communication load20 %
Number of remote interconnection partners32
Number of functions, master/slave50
Total of all master/slave connections3 000
Data length of all incoming connections master/slave, max.24 000 byte
Data length of all outgoing connections master/slave, max.24 000 byte
Number of device-internal and PROFIBUS interconnections1 000
Data length of device-internal und PROFIBUS interconnections, max.8 000 byte
Data length per connection, max.1 400 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min.200 ms
— Number of incoming interconnections100
— Number of outgoing interconnections100
— Data length of all incoming interconnections, max.3 200 byte
— Data length of all outgoing interconnections, max.3 200 byte
— Data length per connection, max.1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min.1 ms
— Number of incoming interconnections300
— Number of outgoing interconnections300
— Data length of all incoming interconnections, max.4 800 byte
— Data length of all outgoing interconnections, max.4 800 byte
— Data length per connection, max.250 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
— HMI variable updating500 ms
— Number of HMI variables600
— Data length of all HMI variables, max.9 600 byte
PROFIBUS proxy functionality
— supportedYes
— Number of linked PROFIBUS devices32
— Data length per connection, max.240 byte; Slave-dependent
Number of connections
overall32
usable for PG communication31
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.31
usable for OP communication31
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.31
usable for S7 basic communication30
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.30
usable for S7 communication16
— reserved for S7 communication0
— adjustable for S7 communication, min.0
— adjustable for S7 communication, max.16
total number of instances, max.32
S7 message functions
Number of login stations for message functions, max.32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.300
Test commissioning functions
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.500
— adjustableNo
— of which powerfail-proof100
Number of entries readable in RUN, max.
— adjustableYes; From 10 to 499
— preset10
Service data
can be read outYes
Ambient conditions
Ambient temperature during operation
min.0 °C
max.60 °C
Configuration
Configuration software
STEP 7Yes; V5.4 SP4 or higher with HW update
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Dimensions
Width120 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.1 250 g
last modified:03/13/2019

External links