6ES7314-1AF11-0AB0
CPU314, 64 KB

From SIEMENS

SIMATIC S7-300, CPU 314 CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 64 KBYTE WORKING MEMORY MICRO MEMORY CARD NECESSARY
General information
HW functional status01
Firmware versionV2.0.0
Engineering with
Programming packageSTEP 7 V5.2 + SP1 or higher with HW update
Supply voltage
Rated value (DC)
24 V DCYes
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)2 A min.
Input current
Current consumption (rated value)0.6 A
Current consumption (in no-load operation), typ.60 mA
Inrush current, typ.2.5 A
I²t0.5 A²·s
Power loss
Power loss, typ.2.5 W
Memory
Work memory
integrated64 kbyte
expandableNo
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 y
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
Battery
Backup battery
Backup time, max.10 y; At 40 °C ambient temperature
CPU processing times
for bit operations, typ.0.1 µs
for bit operations, max.0.2 µs
for word operations, typ.0.2 µs
for fixed point arithmetic, typ.2 µs
for floating point arithmetic, typ.3 µs
CPU-blocks
Number of blocks (total)1 024; (DBs, FCs, FBs OBs, SDBs); the maximum number of loadable blocks can be reduced by the MMC being used.
DB
Number, max.511; Number range: 1 to 511
Size, max.16 kbyte
FB
Number, max.512; Number range: 0 to 2047
Size, max.16 kbyte
FC
Number, max.512; Number range: 0 to 2047
Size, max.16 kbyte
OB
Number, max.see instruction list
Size, max.16 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs1; OB 20
Number of cyclic interrupt OBs1; OB 35
Number of process alarm OBs1; OB 40
Number of startup OBs1; OB 100
Number of asynchronous error OBs1; OB 80
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class8
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number256
Retentivity
— adjustableYes
— presetZ 0 to Z 7
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number256
Retentivity
— adjustableYes
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in totalAll (incl. memory bits, times, counters)
Flag
Number, max.256 byte
Retentivity availableYes; MB 0 to MB 255
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableNo
Retentivity presetYes
Local data
per priority class, max.510 byte
Address area
I/O address area
Inputs1 kbyte
Outputs1 kbyte
Process image
Inputs128 byte
Outputs128 byte
Digital channels
Inputs1 024
— of which central1 024
Outputs1 024
— of which central1 024
Analog channels
Inputs256
— of which central256
Outputs256
— of which central256
Hardware configuration
Number of DP masters
integrated0
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, PtP8
CP, LAN10
Rack
Racks, max.4
Modules per rack, max.8
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s
Operating hours counter
Number1
Number/Number range0
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
in AS, masterYes
Analog inputs
integrated channels (AI)0
Analog outputs
integrated channels (AO)0
1. Interface
Interface typeIntegrated RS 485 interface
PhysicsRS 485
IsolatedNo
Power supply to interface (15 to 30 V DC), max.200 mA
Protocols
MPIYes
PROFIBUS DP masterNo
PROFIBUS DP slaveNo
Point-to-point connectionNo
MPI
Number of connections12
Transmission rate, max.187.5 kbit/s
Services
— PG/OP communicationYes
— RoutingNo
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
Communication functions
PG/OP communicationYes
Global data communication
supportedYes
Number of GD loops, max.4
Number of GD packets, max.4
Number of GD packets, transmitter, max.4
Number of GD packets, receiver, max.4
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; Via CP and loadable FB
User data per job, max.180 byte; With PUT/GET
User data per job (of which consistent), max.64 byte
S5 compatible communication
supportedYes; via CP and loadable FC
Number of connections
overall12
usable for PG communication11
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.11
usable for OP communication11
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.11
usable for S7 basic communication8
— reserved for S7 basic communication8
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.8
S7 message functions
Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.40
Test commissioning functions
Status blockYes
Single stepYes
Number of breakpoints2
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.100
— adjustableNo
Configuration
Configuration software
STEP 7Yes; V5.2 SP1 or higher with HW update
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Dimensions
Width40 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.280 g
last modified:03/13/2019