| SIMATIC PN/PN Coupler for deterministic data exchange between max.4 PN-Controller per subnet, also from subnet to subnet, PROFIsafe data exchange, I/O-, MSI-, MSO- and data record communication, redundant power supply, PN-connection via SIMATIC BusAdapter (BA), delivery w/o BusAdapter |
General information |
Firmware version | V4.2 |
FW update possible | Yes |
Product function |
I&M data | Yes; I&M0 to I&M3 |
Tool changer | Yes; Docking station and docking unit |
Local coupling, IO data | Yes |
— Number of coupling modules | 16 |
— Number of coupling submodules per module | 4; 1x write, 3x read |
Local coupling, data records | Yes |
— Number of coupling modules | 16 |
— Number of coupling submodules per module | 4; 1x write, 3x read |
— Record length, max. | 4 096 byte |
— FIFO depth in storage mode | 8 |
Engineering with |
STEP 7 TIA Portal configurable/integrated as of version | STEP 7 V15.1 or higher |
PROFINET as of GSD version/GSD revision | V2.3 |
Installation type/mounting |
Mounting | Mounting rail 7.5 mm and 15 mm |
Supply voltage |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering |
Mains/voltage failure stored energy time | 10 ms |
Input current |
Current consumption, max. | 360 mA; For 19.2 V input voltage at the right-hand supply terminal, including 2 plugged BA 2x LC |
Inrush current, max. | 1.6 A |
I²t | 0.031 A²·s |
from supply voltage 1L+, max. | 320 mA; For 19.2 V input voltage at the left-hand supply terminal, including 2 plugged BA 2x LC |
Power loss |
Power loss, typ. | 4 W; For 24 V input voltage and 2 plugged BA 2x RJ45 If BusAdapters with an optical interface are plugged, there is an additional 750 mW per optical interface (3 W with 2 plugged BA 2x LC) |
Address area |
Address space per module |
Address space per module, max. | 254 byte; max. 254 bytes of input data and 253 bytes of output data |
Address space per station |
Address space per station, max. | 1 440 byte; per input / output |
Hardware configuration |
Submodules |
Number of submodules per station, max. | 116 |
Interfaces |
Number of PROFINET interfaces | 2; One PROFINET interface per line side |
With optical interface | Yes; Via SIMATIC BusAdapter |
Supports protocol for PROFINET IO |
automatic detection of transmission rate | Yes |
Transmission rate, max. | 100 Mbit/s |
1. Interface |
Interface types |
Number of ports | 2; via BusAdapter |
integrated switch | Yes |
BusAdapter (PROFINET) | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC |
Protocols |
PROFINET IO Device | Yes |
Open IE communication | Yes |
Media redundancy | Yes; As MRP or MRPD client; max. 50 or 30 devices in the ring |
2. Interface |
Interface types |
Number of ports | 2; via BusAdapter |
integrated switch | Yes |
Protocols |
PROFINET IO Device | Yes |
Open IE communication | Yes |
Media redundancy | Yes; As MRP or MRPD client; max. 50 or 30 devices in the ring |
Interface types |
RJ 45 (Ethernet) |
Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
10 Mbps | No |
100 Mbps | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
Autonegotiation | Yes |
Autocrossing | Yes |
Protocols |
Supports protocol for PROFINET IO | Yes |
Protocols (Ethernet) |
TCP/IP | Yes |
SNMP | Yes |
LLDP | Yes |
ping | Yes |
ARP | Yes |
PROFINET IO Device |
Services |
— Isochronous mode | No |
— Open IE communication | Yes |
— IRT | Yes |
— PROFIenergy | No |
— Prioritized startup | Yes |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 4; per line side |
Redundancy mode |
MRP | Yes |
MRPD | Yes |
PROFINET system redundancy (S2) | Yes; NAP S2 acc. to IEC |
Open IE communication |
TCP/IP | Yes |
SNMP | Yes |
LLDP | Yes |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) | No; For operation on isochronous bus |
Interrupts/diagnostics/status information |
Status indicator | Yes |
Alarms | Yes |
Diagnostics function | Yes; Parameterizable |
Diagnostics indication LED |
RUN LED | Yes; Green LED |
ERROR LED | Yes; Red LED |
MAINT LED | Yes; yellow LED |
Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Connection to network LINK (green) | Yes; 2x green link LEDs on BusAdapter |
Potential separation |
between supply voltage and electronics | Yes; to power input 2 |
between Ethernet and electronics | Yes |
Isolation |
Isolation tested with | 707 V DC (type test) |
Standards, approvals, certificates |
Network loading class | 3 |
Security level | According to Security Level 1 Test Cases V1.1.4 |
Ambient conditions |
Ambient temperature during operation |
min. | 0 °C |
max. | 60 °C; = Tmax for horizontal installation; for vertical installation Tmax = 50 °C |
Altitude during operation relating to sea level |
Installation altitude above sea level, max. | 2 000 m |
Ambient air temperature-barometric pressure-altitude | On request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m |
Mechanics/material |
Strain relief | Yes; Optional, for RJ45 and FC BusAdapter only |
Dimensions |
Width | 100 mm; Minimized with good handling |
Height | 117 mm |
Depth | 74 mm; with mounting rail |
Weights |
Weight, approx. | 200 g; without BusAdapter |
last modified: | 03/12/2019 |