6EP4133-0JB00-0AY0
SITOP UPS1100 BAT.MODUL 24V/5AH LIFEPO

From SIEMENS

SITOP UPS1100 BAT.MODUL 24V/5AH LIFEPO
SITOP UPS1100 Battery module with warning not closed Lithium iron phophate batteries for SITOP DC-USV modules DC 24 V 5 Ah
Charging current charging voltage
End-of-charge voltage at DC
at -10 °C recommended28.8 V
at 0 °C recommended28.8 V
at 10 °C recommended28.8 V
at 20 °C recommended28.8 V
at 30 °C recommended28.8 V
at 40 °C recommended28.8 V
at 50 °C recommended28.8 V
Output
Rated current value Iout rated20 A
Permissible charging current, max.2.1 A
Rated voltage Vout DC24 V
Safety
Short-circuit protectionBattery fuse 25 A/32 V (FKS blade-type fuse + holder); overcurrent switch-off at 60 A > 30 ms/min and 24 A > 5 s/min
Design of the overload protectionValve control
Status displayLED green: Battery OK; LED flashing green: Error or warning; OFF: No communication
Safety
Protection classClass III
Degree of protection (EN 60529)IP20
Approvals
CE markYes
UL/cUL (CSA) approvalcURus-Recognized (UL 1778, CSA C22.2 No. 107.1), File E219627
Explosion protection-
ApprovalsYes
Marine approvalDNV GL, ABS
environmental conditions
Operating data noteFor storage, mounting and operation of batteries, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Part 2/EN 50272-2) must be observed.
Ambient temperature
during operation-20 ... +50 °C
during transport-40 ... +60 °C
during storage-40 ... +60 °C
Relative temporary capacity loss at 20 °C in a month typical3 %
Service life
Service life of energy storage
typical Notecapacity falls to 50 % of original capacity
at 20 °C typical15 y
at 30 °C typical10 y
at 40 °C typical9 y
at 50 °C typical2 y
Ambient temperature during storage NoteAlong with the storage and operating temperature, other factors such as the duration of the storage period and the charge status during storage have a decisive influence on the possible useful life. Batteries should therefore be stored as briefly as possible, always fully charged, and within the temperature range 0 to +20 °C.
Mechanics
Connection technologyscrew-type terminals
Connection for power supply unit1 screw terminal each for 0.5 ... 16 mm² for + BAT and - BAT
Type of electrical connection for control circuit and status message1 screw terminal each for 0.14 ... 4 mm²
Product component belonging toAccessories pack with solid-state circuitry fuse 25 A
Width of the enclosure189 mm
Height of the enclosure186 mm
Depth of the enclosure113 mm
Installation width189 mm
Installation height201 mm
Weight, approx.3.4 kg
Installationsnaps onto DIN rail EN 60715 35x15 or keyhole mounting for hooking in to M4 screws
Number of cells16
Battery5 A·h
Reference code acc. to DIN EN 81346-2G
Other informationSpecifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)