6EP1321-1LD00
PSU100D 12 V/3 A

From SIEMENS

PSU100D 12 V/3 A
PSU100D 12 V/3 A Stabilized power supply input: 100-240 V AC output: 12 V DC/3 A
Input
Input1-phase AC
Rated voltage value Vin rated100 ... 240 V
Voltage range AC85 ... 264 V
Wide-range inputYes
Mains buffering at Iout rated, min.15 ms; at Vin = 115/230 V
Rated line frequency 150 Hz
Rated line frequency 260 Hz
Rated line range47 ... 63 Hz
Input current
at rated input voltage 100 V0.75 A
at rated input voltage 240 V0.5 A
Switch-on current limiting (+25 °C), max.60 A
I²t, max.1.2 A²·s
Built-in incoming fuseinternal
Protection in the mains power input (IEC 898)Recommended miniature circuit breaker: from 10 A characteristic C or from 16 A characteristic B
Output
OutputControlled, isolated DC voltage
Rated voltage Vout DC12 V
Total tolerance, static ±2 %
Static mains compensation, approx.0.5 %
Static load balancing, approx.1 %
Residual ripple peak-peak, max.100 mV
Spikes peak-peak, max. (bandwidth: 20 MHz)100 mV
Adjustment range11 ... 14 V
Product function Output voltage adjustableYes
Output voltage settingvia potentiometer
Status displayGreen LED for 12 V OK
On/off behaviorOvershoot of Vout < 2 %
Startup delay, max.2.5 s
Voltage increase time of the output voltage maximum30 ms
Rated current value Iout rated3 A
Current range0 ... 3 A
Note+50 ... +70 °C: Derating 2.5%/K
Supplied active power typical36 W
Parallel switching for enhanced performanceYes
Numbers of parallel switchable units for enhanced performance2
Efficiency
Efficiency at Vout rated, Iout rated, approx.84 %
Power loss at Vout rated, Iout rated, approx.6.5 W
Closed-loop control
Dynamic mains compensation (Vin rated ±15 %), max.0.5 %
Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ.5 %
Protection and monitoring
Output overvoltage protection< 17.6 V
Current limitation, typ.3.6 A
Property of the output Short-circuit proofYes
Short-circuit protectionElectronic shutdown, automatic restart
Enduring short circuit current RMS value
typical6 A
Overload/short-circuit indicator-
Safety
Primary/secondary isolationYes
Galvanic isolationSafety extra low output voltage Vout according to EN 60950-1
Protection classClass I
Leakage current
maximum3.5 mA
typical1 mA
CE markYes
UL/cUL (CSA) approvalcULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus (UL 60950-1, CSA C22.2 No. 60950-1), File E151273
Explosion protection-
FM approval-
CB approvalYes
Marine approval-
Degree of protection (EN 60529)IP20
EMC
Emitted interferenceEN 55022 Class B
Supply harmonics limitationnot applicable
Noise immunityEN 61000-6-2
Operating data
Ambient temperature
during operation-10 ... +70 °C
— Notewith natural convection
during transport-40 ... +85 °C
during storage-40 ... +85 °C
Mechanics
Connection technologyscrew-type terminals
Connections
Supply inputL, N, PE: 1 screw terminal each for 0.3 ... 1.3 mm² single-core/finely stranded
Output+, -: 1 screw terminal each for 0.3 ... 1.3 mm²
Auxiliary-
Width of the enclosure97 mm
Height of the enclosure98 mm
Depth of the enclosure38 mm
Required spacing
top20 mm
bottom0 mm
left20 mm
right20 mm
Weight, approx.0.37 kg
InstallationWall mounting
Other informationSpecifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)