| SIMATIC ET 200SP HA, PROFINET interface module IM155-6 PN max. 56 I/O modules, multi-hot swap, without server module |
General information |
Product type designation | IM 155-6 PN |
HW functional status | FS03 |
Firmware version | V1.1 |
Vendor identification (VendorID) | 02AH |
Device identifier (DeviceID) | 030FH |
Product function |
I&M data | Yes; I&M0 to I&M3 |
Engineering with |
PCS 7 configurable/integrated as of version | V9.0 |
Configuration control |
via dataset | No |
Supply voltage |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Short-circuit protection | Yes |
Mains buffering |
Mains/voltage failure stored energy time | 10 ms |
Input current |
Current consumption, max. | 700 mA; +19.2 V to +28.8 V DC |
Inrush current, max. | 5 A |
I²t | 0.36 A²·s; Due to increased mains buffering of 10 ms |
Power |
Infeed power to the backplane bus | 7.5 W; No doubling in redundant mode as the infeed power is also designed as redundant. |
Power loss |
Power loss, typ. | 2.4 W |
Address area |
Address space per module |
Address space per module, max. | 256 byte |
Address space per station |
Address space per station, max. | 1 440 byte; 1 440 bytes R1 and S1 without CiR, otherwise 1 000 bytes |
Hardware configuration |
Integrated power supply | Yes; 24 V DC |
Rack |
Modules per rack, max. | 56; 56 slots for I/O modules + server module (width without IM ≤ 1.3 m) |
Time stamping |
Accuracy | 1 ms; In compliance with the supplementary conditions described in the Equipment Manual |
Interfaces |
Number of PROFINET interfaces | 1; 2 ports (switch) |
1. Interface |
Interface types |
Number of ports | 2; via BusAdapter |
integrated switch | Yes |
BusAdapter (PROFINET) | Yes; Compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA VD |
Protocols |
PROFINET IO Device | Yes |
Open IE communication | Yes |
Media redundancy | Yes; as MRP client |
Interface types |
RJ 45 (Ethernet) |
Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
100 Mbps | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
Autonegotiation | Yes |
Autocrossing | Yes |
Protocols |
PROFINET IO Device |
Services |
— Open IE communication | Yes |
Redundancy mode |
MRP | Yes |
PROFINET system redundancy (S2) | Yes; S2, R1 |
Open IE communication |
TCP/IP | Yes |
SNMP | Yes |
LLDP | Yes |
Interrupts/diagnostics/status information |
Status indicator | Yes |
Alarms | Yes |
Diagnostics function | Yes |
Diagnostics indication LED |
RUN LED | Yes; Green LED |
ERROR LED | Yes; Red LED |
MAINT LED | Yes; yellow LED |
ACTIVE-LED (active IM in redundant configuration) | Yes; Green LED |
Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter |
Potential separation |
between PROFINET and all other circuits | Yes; 1500 V AC |
between supply and all other circuits | Yes; Type tested with 1 500 V DC |
Permissible potential difference |
between different circuits | Safety extra low voltage SELV |
Isolation |
Isolation tested with | 1 500 V DC/1 min, type test |
Ambient conditions |
Ambient temperature during operation |
horizontal installation, min. | -40 °C |
horizontal installation, max. | 70 °C |
vertical installation, min. | -40 °C |
vertical installation, max. | 60 °C |
Dimensions |
Width | 50 mm |
Height | 138 mm |
Depth | 89 mm |
Weights |
Weight, approx. | 192 g; without BusAdapter |
last modified: | 03/12/2019 |