| SIMATIC ET 200SP HA, Signal relay module changeover contact, RQ 4x120VDC-230VAC/5A CO HA suitable for terminal block K0, color code CC40, module diagnostics |
General information |
Product type designation | RQ 4x120 V UC ... 230 V AC/5 A CO HA |
Firmware version | V1.0 |
FW update possible | Yes |
Usable terminal block | TB type K0 |
Color code for module-specific color identification plate | CC40 |
Product function |
I&M data | Yes; I&M0 to I&M3 |
Engineering with |
PCS 7 configurable/integrated as of version | V9.0 |
Redundancy |
Redundancy capability | No |
Supply voltage |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Input current |
Current consumption (rated value) | 50 mA; At 24 V and energized changeover coils |
Current consumption, max. | 60 mA; At 19.2 V and energized changeover coils |
Power loss |
Power loss, typ. | 2.8 W; At 24 V, energized changeover coils and 5 A current across each changeover contact |
Address area |
Address space per module |
Address space per module, max. | 1 byte; + 1 byte for QI information |
Digital outputs |
Number of digital outputs | 4 |
Switching frequency |
with resistive load, max. | 2 Hz |
with inductive load, max. | 0.5 Hz |
on lamp load, max. | 2 Hz |
Total current of the outputs |
Current per channel, max. | 5 A |
Current per module, max. | 20 A |
Total current of the outputs (per module) |
horizontal installation |
— up to 70 °C, max. | 20 A |
vertical installation |
— up to 60 °C, max. | 20 A |
Relay outputs |
Number of relay outputs | 4 |
external protection for relay outputs | yes; 6 A, see data in manual |
Switching capacity of contacts |
— with inductive load, max. | 2 A; 2 A (24 V DC), 0.5 A (60 V DC), 0.1 A (120 V DC) |
— with resistive load, max. | 5 A; 5 A (30 V DC), 5 A (230 V AC) |
— Switching current, min. | 8 mA |
— Rated switching voltage (DC) | 24 V; 24 V DC to 120 V DC |
— Rated switching voltage (AC) | 230 V; 24V AC to 230V AC |
Cable length |
shielded, max. | 1 000 m |
unshielded, max. | 200 m |
Interrupts/diagnostics/status information |
Diagnostics function | Yes |
Substitute values connectable | Yes |
Alarms |
Diagnostic alarm | Yes |
Diagnostic messages |
Monitoring the supply voltage | Yes |
— parameterizable | Yes |
Diagnostics indication LED |
MAINT LED | Yes; yellow LED |
Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Channel status display | Yes; Green LED |
for module diagnostics | Yes; green/red DIAG LED |
Potential separation |
Potential separation channels |
between the channels | Yes |
between the channels and backplane bus | Yes |
Between the channels and load voltage L+ | Yes |
Permissible potential difference |
between different circuits | Between channels: 230 V AC (different system phase) |
between channels and backplane bus/supply voltage | 230 V AC |
Isolation |
tested with |
between channels and backplane bus/supply voltage | 4 200 V DC/1 min, type test |
between backplane bus and supply voltage | 1 500 V DC/1 min, type test |
Between channels | 1 500 V AC/1 min, type test |
Ambient conditions |
Ambient temperature during operation |
horizontal installation, min. | -40 °C; No icing |
horizontal installation, max. | 70 °C |
vertical installation, min. | -40 °C; No icing |
vertical installation, max. | 60 °C |
Altitude during operation relating to sea level |
Ambient air temperature-barometric pressure-altitude | 3 000 m due to converter type used |
Dimensions |
Width | 22.5 mm |
Height | 115 mm |
Depth | 138 mm |
Weights |
Weight, approx. | 162 g |