| SIEMENS ORDER NUMBER IS DISCONNECTED SINCE JUNE 6.2009 SUCCESSOR: 6BK1700-2AA10-0AA1 |
Installation type/mounting |
Mounting type | Control cabinet backplane |
Mounting position | Horizontal |
Type of ventilation | Self ventilation or forced ventilation |
Supply voltage |
Type of supply voltage | AC |
Rated value (AC) | 230 V |
Relative negative tolerance | 18 % |
Relative positive tolerance | 15 % |
Line frequency |
Rated value 50 Hz | Yes |
Rated value 60 Hz | Yes |
Relative symmetrical tolerance | 5 % |
Mains buffering |
Mains/voltage failure stored energy time | 20 ms |
Recovery time after power failure, typ. | 1 s |
Connection method |
Design of electrical connection for supply voltage | Connector, 2-pole |
— Connectable conductor cross-sections, solid | 1x (0.2 ... 2.5 mm²) |
— Connectable conductor cross-sections, finely stranded with wire end processing | 1x (0.25 ... 2.5 mm²) |
— Connectable conductor cross-sections for AWG cables | 24 ... 12 |
Power |
Active power input | 15 W |
Hardware configuration |
Type of power output connectable | LA716 / LA716I / LA716I HP |
Power capacity per rack with fan, max. | 176 kW |
Power capacity per rack without fan, max. | 67 kW |
Slots |
Number of slots | 12 |
Interfaces |
Interfaces/bus type | PROFIBUS DP |
Protocols |
PROFIBUS DP | Yes |
Interrupts/diagnostics/status information |
Number of status displays | 2 |
LED status display | LED green = status indicator, LED red = fault indicator |
Isolation |
Overvoltage category | III |
Degree of pollution | 2 |
EMC |
EMC interference emission | in accordance with EN 61000-6-4:2007 + A1:2011 |
Electrostatic discharge acc. to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
Field-related interference acc. to IEC 61000-4-3 | 10 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz) |
Conducted interference due to burst acc. to IEC 61000-4-4 | 2 kV voltage supply cables / 2 kV signal cables |
Conducted interference due to surge acc. to IEC 61000-4-5 | On supply lines: 1 kV symmetrical, 2 kV asymmetrical, PROFIBUS cable asymmetrical 1 kV |
Conducted interference due to high-frequency radiation acc. to IEC 61000-4-6 | 10 V in the frequency range 0.15 ... 80 MHz, Mmdulation 80 % AM at 1 kHz, evaluation criterion A |
Degree and class of protection |
IP degree of protection | IP00 |
Standards, approvals, certificates |
Certificate of suitability | CE, KCC |
CE mark | Yes |
KC approval | Yes |
EAC (formerly Gost-R) | Yes |
China RoHS compliance | Yes |
Reference designation according to DIN EN 81346-2 | K |
Ambient conditions |
Ambient temperature during operation |
min. | 0 °C |
max. | 55 °C |
Ambient temperature during storage/transportation |
Storage, min. | -40 °C |
Storage, max. | 70 °C |
Transportation, min. | -40 °C |
Transportation, max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 |
Operation, min. | 860 hPa |
Operation, max. | 1 080 hPa |
Storage, min. | 660 hPa |
Storage, max. | 1 080 hPa |
Altitude during operation relating to sea level |
Installation altitude above sea level, max. | 2 000 m |
Relative humidity |
Operation at 25 ℃, max. | 95 % |
Shock testing |
Shock resistance during operation acc. to IEC 60068-2-27 | 15 g / 11 ms / 3 shocks/axis |
Shock resistance during storage acc. to IEC 60068-2-29 | 25 g / 6 ms / 1 000 shocks/axis |
Dimensions |
Width | 510 mm |
Height | 310 mm |
Depth | 330 mm |
last modified: | 03/13/2019 |