6AV7260-.....-....
SIMATIC IPC677D

From SIEMENS

SIMATIC IPC677D (Panel PC), 2x10/100/1000 Mbit/s Ethernet; 4x USB V3.0, 1x serial (COM1); Watchdog, temperature and Fan monitoring; RAID controller onboard
General information
Product type designationIPC677D
Installation type/mounting
MountingFor horizontal and vertical mounting
DesignPanel PC, built-in unit
maximum permissible installation angle +/-20°
Supply voltage
Type of supply voltage100/240 V AC (autorange); 24 V DC
Line frequency
Rated value 50 HzYes
Rated value 60 HzYes
Mains buffering
Mains/voltage failure stored energy time10 ms
Processor
Processor typeCeleron G1820TE (2C/2T, 2.2 GHz, 2 MB Cache); Core i3-4330TE (2C/4T, 2.4 GHz, 4 MB Cache); Xeon E3-1268L v3 (4C/8T, 2.3 (3.3) GHz, 8 MB Cache, AMT)
ChipsetIntel DH82C226 PCH
Graphic
Graphics controllerIntel HD graphics controller P4600 GT2 (Xeon, Core i3); Intel HD graphics controller (Celeron)
Drives
Optical drivesDVD±R±RW combi-drive, optional
Hard disk3.5" SATA ≥ 500 GB, optional: 3.5" SATA ≥ 1 TB; RAID1 2x 2.5" SATA ≥ 320 GB; solid-state drive (SSD) ≥ 240 GB; all hard disk drives within the enclosure are vibration-damped; RAID1 2x 2.5" SATA ≥ 320 GB byte in removable drive bay
SSDYes; ≥ 240 GB optional
Memory
Type of memoryDDR3 1600 DIMM
Main memory2 / 4 / 8 / 16 GB; ECC optional
Capacity of main memory, max.16 Gbyte
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.2 Mbyte; 128 KB can be stored in the buffer time; optional
Hardware configuration
Slots
free slots2x PCI; optional: 1x PCI & 1x PCIe (x16); 2x PCIe (x4, x16); with card retainer
Number of PCI slots2
Number of PCI slots2
Interfaces
PROFIBUS/MPIOptionally onboard, isolated, max. 12 Mbit/s, compatible with CP 5622
Number of industrial Ethernet interfaces2; 2x RJ45 (independent)
Number of PROFINET interfaces3; Optional
USB port4x USB 3.0
Connection for keyboard/mouseUSB / USB
serial interface1x COM1 (RS 232), optional: 1x COM2 (RS 232)
parallel interfaceoptional LPT1
Video interfaces
Graphics interface1x DisplayPort and 1x DVI-I; 1x VGA via adapter cable (optional)
Industrial Ethernet
Industrial Ethernet interfaceOnboard, 2x 10 / 100 / 1000 Mbit, RJ45
— 100 MbpsYes
— 1000 MbpsYes
Interrupts/diagnostics/status information
Bus diagnosticsYes
Integrated Functions
Monitoring functions
Temperature monitoringYes
WatchdogYes
Status LEDsYes
FanYes
Monitoring function via networkOptional
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2
Interference immunity against high-frequency electromagnetic fields
Interference immunity against high frequency radiation10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6
Interference immunity to cable-borne interference
Interference immunity on supply cables±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5, surge symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric
Interference immunity on signal cables >30m±2 kV acc. to IEC 61000-4-5, surge, length > 30 m
Interference immunity on signal cables < 30m±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m
Interference immunity against voltage surge
asymmetric interference±2 kV acc. to IEC 61000-4-5, surge asymmetric
symmetric interference±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
Interference immunity to magnetic fields at 50 Hz100 A/m; to IEC 61000-4-8
Emission of conducted and non-conducted interference
Interference emission via line/AC current cablesEN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A
Degree and class of protection
IP (at the front)IP65
IP (rear)IP20
Standards, approvals, certificates
CE markYes
UL approvalYes
UL 508Yes
cULusYes
RCM (formerly C-TICK)Yes
KC approvalYes
FCCYes
EMCCE, EN 61000-6-4:2007, EN 61000-6-2:2005
Ambient conditions
Ambient temperature during operation
Ambient temperature during operation+5 °C to +45 °C with full configuration
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Relative humidity
Relative humidityTested according to IEC 60068-2-78, IEC 60068-2-30: 5% to 80% at 25 °C (no condensation)
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-6Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s² (1g)
Shock testing
Shock load during operationTested to DIN IEC 60068-2-29: 50 m/s² (5 g), 30 ms, 100 shocks
Operating systems
Operating systemWindows 7 Ultimate, 32-bit/64-bit, MUI; Windows Embedded Standard 7 P, 32-bit, MUI; Windows 10 Enterprise 2015 or 2016 LTSB, 64-bit, MUI
pre-installed operating systemYes
without operating systemYes
pre-installed operating system
Windows 7Yes; Ultimate 32 bit or 64 bit
Windows 10 EnterpriseYes; Windows 10 Enterprise 2015 or 2016 LTSB, 64-bit, MUI
Software
SIMATIC SoftwareOptional package with SIMATIC WinCC or WinAC RTX