| SIMATIC IPC477E PRO fully enclosed IP65; 4USB (back); w/o USB (front); Ethernet (10/100/1000); |
| Installation type/mounting |
| Mounting | For mounting on stand or supporting bracket |
| Design | Panel PC on pedestal or supporting arm |
| maximum permissible installation angle +/- | ±45 ° |
| Supply voltage |
| Type of supply voltage | 24 V DC |
| Line frequency |
| Rated value 50 Hz | Yes |
| Rated value 60 Hz | Yes |
| Processor |
| Processor type | Celeron G3902 (2C/2T, 1.6 GHz, 2 MB Cache); Core i3-6102E (2C/4T, 1.9 GHz, 3 MB Cache); Core i5-6442EQ (4C/4T, 1.9 (2.7) GHz, 6 MB Cache, iAMT); Xeon E3-1505L v5 (4C/8T, 2.0 (2.8) GHz, 8 MB Cache, iAMT) |
| Graphic |
| Graphics controller | Intel HD graphics controller |
| Drives |
| Optical drives | possible as external drive via USB |
| SSD | Yes; 1x 128 GB, 1x 240 GB SSD, 1x 480 GB SSD |
| Memory |
| Type of memory | DDR4 SO-DIMM |
| Main memory | 4 GB to 16 GB, ECC optional |
| Capacity of main memory, max. | 16 Gbyte |
| Data areas and their retentivity |
| Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; 128 KB can be stored in the buffer time |
| Hardware configuration |
| Slots |
| Number of PCI slots | 0; Different to the built-in unit |
| Number of PCI slots | 0; Different to the built-in unit |
| Number of compact flash slots | 1; CFast |
| Interfaces |
| Number of industrial Ethernet interfaces | 3; 3x Ethernet (RJ45) |
| USB port | 4x USB 3.0 onboard (rear) |
| Connection for keyboard/mouse | USB / USB |
| serial interface | Without / 2x COM (RS 232 / 422 / 485), selectable in the BIOS |
| Video interfaces |
| Graphics interface | 2x DisplayPort |
| Industrial Ethernet |
| Industrial Ethernet interface | 3x Ethernet (RJ45) |
| — 100 Mbps | Yes |
| — 1000 Mbps | Yes |
| Interrupts/diagnostics/status information |
| Bus diagnostics | Yes |
| Integrated Functions |
| Monitoring functions |
| Temperature monitoring | Yes |
| Watchdog | Yes |
| Fan | No |
| Monitoring function via network | Optional |
| EMC |
| Interference immunity against discharge of static electricity |
| Interference immunity against discharge of static electricity | ±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2 |
| Interference immunity against high-frequency electromagnetic fields |
| Interference immunity against high frequency radiation | 10 V/m, 80 ... 2 000 MHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 ... 2.7 GHz; 10 V, 10 kHz ... 80 MHz acc. to IEC 61000-4-6 |
| Interference immunity to cable-borne interference |
| Interference immunity on supply cables | ±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5, surge symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric |
| Interference immunity on signal cables >30m | ±2 kV acc. to IEC 61000-4-5, surge, length > 30 m |
| Interference immunity on signal cables < 30m | ±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m |
| Interference immunity against voltage surge |
| asymmetric interference | ±2 kV acc. to IEC 61000-4-5, surge asymmetric |
| symmetric interference | ±1 kV acc. to IEC 61000-4-5, surge symmetric |
| Interference immunity to magnetic fields |
| Interference immunity to magnetic fields at 50 Hz | 100 A/m; to IEC 61000-4-8 |
| Emission of conducted and non-conducted interference |
| Interference emission via line/AC current cables | EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A |
| Degree and class of protection |
| IP65 (all-round) | Yes; IP65 fully enclosed |
| IP (at the front) | IP65 |
| IP (rear) | IP65 |
| Standards, approvals, certificates |
| CE mark | Yes; CE marking / EC Declaration of Conformity |
| UL approval | Yes |
| UL 508 | Yes |
| cULus | Yes |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| EAC (formerly Gost-R) | No |
| EMC | CE, EN 61000-6-4; CISPR 22 Class A; FCC Class A |
| Marine approval |
| Germanischer Lloyd (GL) | Yes |
| American Bureau of Shipping (ABS) | Yes |
| Det Norske Veritas (DNV) | Yes |
| Korean Register of Shipping (KRS) | Yes |
| Lloyds Register of Shipping (LRS) | Yes |
| Ambient conditions |
| Ambient temperature during operation |
| Ambient temperature during operation | 5 to +45°C |
| Ambient temperature during storage/transportation |
| min. | -20 °C |
| max. | 60 °C |
| Relative humidity |
| Relative humidity | Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 °C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 °C (no condensation) |
| Vibrations |
| Vibration resistance during operation acc. to IEC 60068-2-6 | Tested to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm, 58 Hz to 200 Hz: 9.8 m/s² (1 g) |
| Shock testing |
| Shock load during operation | Tested according to IEC 60068-2-27, IEC 60068-2-29: half-sine: 50 m/s² (5 g), 30 ms, 100 shocks per axis |
| Operating systems |
| Operating system | Windows 7 Ultimate (Multi-Language) 64-bit, Windows Embedded Standard 7 E/P 32-bit / 64-bit, Windows 10 |
| pre-installed operating system | Yes |
| without operating system | Yes; Optional |
| pre-installed operating system |
| Windows 7 | Yes; Ultimate 64 bit |
| Windows 10 Enterprise | Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI |
| last modified: | 03/13/2019 |