| SIMATIC IPC 477D, computing unit, 4 USB (back), Ethernet (10/100/1000) |
Installation type/mounting |
Mounting | For horizontal and vertical mounting |
Design | Panel PC, built-in unit |
Supply voltage |
Type of supply voltage | 100/240 V AC (autorange) 50/60 Hz; optional 24 V DC |
Line frequency |
Rated value 50 Hz | Yes |
Rated value 60 Hz | Yes |
Mains buffering |
Mains/voltage failure stored energy time | 10 ms |
Processor |
Processor type | Celeron 827E (1C/1T, 1.40 GHz, 1.5 MB Cache); Core i3-3217UE (2C/4T, 1.60 GHz, 3 MB Cache); Core i7-3517UE (2C/4T, 1.70 (2.80) GHz, 4 MB Cache, iAMT) |
Graphic |
Graphics controller | Intel HD graphics controller |
Drives |
Optical drives | Optional: DVD±R±RW combi drive; on rear, can be operated from side |
Hard disk | 2.5" SATA hard disk, at least 320 GB |
SSD | Yes; 1x 240 GB SSD, 1x 480 GB SSD |
Memory |
Type of memory | DDR3-SDRAM |
Main memory | 2 / 4 / 8 GB; ECC optional |
Capacity of main memory, max. | 8 Gbyte |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; 128 KB can be stored in the buffer time; optional |
Hardware configuration |
Slots |
free slots | 1x PCIe (slot with card retainer), 1x slot for CFAST card |
Number of PCI slots | 1; Optional |
Number of compact flash slots | 2; CFast |
Interfaces |
PROFIBUS/MPI | Optionally onboard, isolated, max. 12 Mbps, compatible with CP 5611 |
Number of PROFINET interfaces | 3; 3 ports (IRT, with switch, optional) |
USB port | 4x USB 3.0 high speed/high current |
Connection for keyboard/mouse | USB / USB |
serial interface | COM1: 1x RS 232, COM2 (optional): 1x RS 232 |
Video interfaces |
Graphics interface | DVI VGA / DVI integrated |
Industrial Ethernet |
Industrial Ethernet interface | Onboard, 2x 10/100 Mbit, RJ45, no plug-in card necessary |
Interrupts/diagnostics/status information |
Bus diagnostics | Yes |
Integrated Functions |
Monitoring functions |
Temperature monitoring | Yes |
Watchdog | Yes |
Status LEDs | Yes |
Fan | No |
Monitoring function via network | Optional |
EMC |
Interference immunity against discharge of static electricity |
Interference immunity against discharge of static electricity | ± 6 KV contact discharge at the front in accordance with IEC 61000-4-2; ±4 kV, housing contact discharge at the back in accordance with IEC 61000-4-2; ± 8 kV air discharge in accordance with IEC 61000-4-2 |
Interference immunity against high-frequency electromagnetic fields |
Interference immunity against high frequency radiation | 10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6 |
Interference immunity to cable-borne interference |
Interference immunity on supply cables | ±2 kV (to IEC 1000-4-4; 1995; burst); ±1 kV (to IEC 1000-4-5; 1995; surge symm); ±2 kV (to IEC 1000-4-5; 1995; surge asymm) |
Interference immunity on signal cables >30m | ±2 kV acc. to IEC 61000-4-4, burst; length > 30 m; ±2 kV acc. to IEC 61000-4-5, surge; length > 30 m |
Interference immunity on signal cables < 30m | ±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m |
Interference immunity against voltage surge |
asymmetric interference | ±2 kV acc. to IEC 61000-4-5, surge asymmetric |
symmetric interference | ±1 kV acc. to IEC 61000-4-5, surge symmetric |
Interference immunity to magnetic fields |
Interference immunity to magnetic fields at 50 Hz | 100 A/m; to IEC 61000-4-8 |
Emission of conducted and non-conducted interference |
Interference emission via line/AC current cables | EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A |
Degree and class of protection |
IP (at the front) | IP65 |
IP (rear) | IP20 |
Standards, approvals, certificates |
CE mark | Yes; CE marking / EC Declaration of Conformity |
UL approval | Yes |
UL 508 | Yes |
cULus | Yes |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
FCC | Yes |
EMC | CE, EN 61000-6-4; CISPR 22:2004 Class A; FCC Class A |
Use in hazardous areas |
ATEX Zone 2 | Yes; Optional |
ATEX Zone 22 | Yes; Optional |
IECEx Zone 2 | Yes; Optional |
cULus Class I Zone 2, Division 2 | Yes |
Marine approval |
Germanischer Lloyd (GL) | Yes |
American Bureau of Shipping (ABS) | Yes |
Bureau Veritas (BV) | Yes |
Det Norske Veritas (DNV) | Yes |
Korean Register of Shipping (KRS) | Yes |
Lloyds Register of Shipping (LRS) | Yes |
Nippon Kaiji Kyokai (Class NK) | Yes |
Ambient conditions |
Ambient temperature during operation |
Ambient temperature during operation | 0 °C to +45 °C with full configuration |
Ambient temperature during storage/transportation |
min. | -20 °C |
max. | 60 °C |
Relative humidity |
Relative humidity | Tested according to IEC 60068-2-78, IEC 60068-2-30: 5% to 80% at 25 °C (no condensation) |
Vibrations |
Vibration resistance during operation acc. to IEC 60068-2-6 | IEC 60068-2-6; 5 Hz to 9 Hz: 3.5 mm; 9 Hz to 500 Hz: 9.8 m/s² (with SSD or CFast); 10 Hz to 58 Hz: 0.0375 mm; 58 Hz to 200 Hz: 4.9 m/s² (hard disk) |
Shock testing |
Shock load during operation | IEC 60068-2-27; 150 m/s², 11 ms (without hard disk); 50 m/s², 30 ms (with hard disk) |
Operating systems |
Operating system | Windows 7 Ultimate 32-bit / 64-bit, MUI; Windows Embedded Standard 7 P, 32-bit, MUI |
pre-installed operating system | Yes |
without operating system | Yes; Optional |
pre-installed operating system |
Windows 7 | Yes; Ultimate 32 bit or 64 bit |
Software |
SIMATIC Software | Optionally with pre-installed software bundle SIMATIC WinCC RT Advanced / WinAC RTX |
last modified: | 03/13/2019 |