6AV7240-.....-....
SIMATIC IPC 477D

From SIEMENS

SIMATIC IPC 477D, computing unit, 4 USB (back), Ethernet (10/100/1000)
Installation type/mounting
MountingFor horizontal and vertical mounting
DesignPanel PC, built-in unit
Supply voltage
Type of supply voltage100/240 V AC (autorange) 50/60 Hz; optional 24 V DC
Line frequency
Rated value 50 HzYes
Rated value 60 HzYes
Mains buffering
Mains/voltage failure stored energy time10 ms
Processor
Processor typeCeleron 827E (1C/1T, 1.40 GHz, 1.5 MB Cache); Core i3-3217UE (2C/4T, 1.60 GHz, 3 MB Cache); Core i7-3517UE (2C/4T, 1.70 (2.80) GHz, 4 MB Cache, iAMT)
Graphic
Graphics controllerIntel HD graphics controller
Drives
Optical drivesOptional: DVD±R±RW combi drive; on rear, can be operated from side
Hard disk2.5" SATA hard disk, at least 320 GB
SSDYes; 1x 240 GB SSD, 1x 480 GB SSD
Memory
Type of memoryDDR3-SDRAM
Main memory2 / 4 / 8 GB; ECC optional
Capacity of main memory, max.8 Gbyte
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.512 kbyte; 128 KB can be stored in the buffer time; optional
Hardware configuration
Slots
free slots1x PCIe (slot with card retainer), 1x slot for CFAST card
Number of PCI slots1; Optional
Number of compact flash slots2; CFast
Interfaces
PROFIBUS/MPIOptionally onboard, isolated, max. 12 Mbps, compatible with CP 5611
Number of PROFINET interfaces3; 3 ports (IRT, with switch, optional)
USB port4x USB 3.0 high speed/high current
Connection for keyboard/mouseUSB / USB
serial interfaceCOM1: 1x RS 232, COM2 (optional): 1x RS 232
Video interfaces
Graphics interfaceDVI VGA / DVI integrated
Industrial Ethernet
Industrial Ethernet interfaceOnboard, 2x 10/100 Mbit, RJ45, no plug-in card necessary
Interrupts/diagnostics/status information
Bus diagnosticsYes
Integrated Functions
Monitoring functions
Temperature monitoringYes
WatchdogYes
Status LEDsYes
FanNo
Monitoring function via networkOptional
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity± 6 KV contact discharge at the front in accordance with IEC 61000-4-2; ±4 kV, housing contact discharge at the back in accordance with IEC 61000-4-2; ± 8 kV air discharge in accordance with IEC 61000-4-2
Interference immunity against high-frequency electromagnetic fields
Interference immunity against high frequency radiation10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6
Interference immunity to cable-borne interference
Interference immunity on supply cables±2 kV (to IEC 1000-4-4; 1995; burst); ±1 kV (to IEC 1000-4-5; 1995; surge symm); ±2 kV (to IEC 1000-4-5; 1995; surge asymm)
Interference immunity on signal cables >30m±2 kV acc. to IEC 61000-4-4, burst; length > 30 m; ±2 kV acc. to IEC 61000-4-5, surge; length > 30 m
Interference immunity on signal cables < 30m±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m
Interference immunity against voltage surge
asymmetric interference±2 kV acc. to IEC 61000-4-5, surge asymmetric
symmetric interference±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
Interference immunity to magnetic fields at 50 Hz100 A/m; to IEC 61000-4-8
Emission of conducted and non-conducted interference
Interference emission via line/AC current cablesEN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A
Degree and class of protection
IP (at the front)IP65
IP (rear)IP20
Standards, approvals, certificates
CE markYes; CE marking / EC Declaration of Conformity
UL approvalYes
UL 508Yes
cULusYes
RCM (formerly C-TICK)Yes
KC approvalYes
FCCYes
EMCCE, EN 61000-6-4; CISPR 22:2004 Class A; FCC Class A
Use in hazardous areas
ATEX Zone 2Yes; Optional
ATEX Zone 22Yes; Optional
IECEx Zone 2Yes; Optional
cULus Class I Zone 2, Division 2Yes
Marine approval
Germanischer Lloyd (GL)Yes
American Bureau of Shipping (ABS)Yes
Bureau Veritas (BV)Yes
Det Norske Veritas (DNV)Yes
Korean Register of Shipping (KRS)Yes
Lloyds Register of Shipping (LRS)Yes
Nippon Kaiji Kyokai (Class NK)Yes
Ambient conditions
Ambient temperature during operation
Ambient temperature during operation0 °C to +45 °C with full configuration
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Relative humidity
Relative humidityTested according to IEC 60068-2-78, IEC 60068-2-30: 5% to 80% at 25 °C (no condensation)
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-6IEC 60068-2-6; 5 Hz to 9 Hz: 3.5 mm; 9 Hz to 500 Hz: 9.8 m/s² (with SSD or CFast); 10 Hz to 58 Hz: 0.0375 mm; 58 Hz to 200 Hz: 4.9 m/s² (hard disk)
Shock testing
Shock load during operationIEC 60068-2-27; 150 m/s², 11 ms (without hard disk); 50 m/s², 30 ms (with hard disk)
Operating systems
Operating systemWindows 7 Ultimate 32-bit / 64-bit, MUI; Windows Embedded Standard 7 P, 32-bit, MUI
pre-installed operating systemYes
without operating systemYes; Optional
pre-installed operating system
Windows 7Yes; Ultimate 32 bit or 64 bit
Software
SIMATIC SoftwareOptionally with pre-installed software bundle SIMATIC WinCC RT Advanced / WinAC RTX
last modified:03/13/2019

External links