6AV6645-0CC01-0AX0
Mobile Panel 277

From SIEMENS

SIMATIC Mobile Panel 277 with integrated acknowledgment button, stop button, handwheel, D key-operated switch and two illuminated pushbuttons, configurable with WinCC flexible Standard Version 2005 SP1 or higher or TIA Portal V11 to V14
General information
Product type designation277
Customer-specific configurationYes
Display
Design of displayTFT
Screen diagonal7.5 in
Color displayYes
Number of colors65 536
Resolution (pixels)
Horizontal image resolution640 Pixel
Vertical image resolution480 Pixel
Backlighting
MTBF backlighting (at 25 °C)50 000 h
Control elements
Control elementsKeys and touch
Keyboard fonts
Membrane keyboard
— user-definable label membrane keysYes
Function keys
— Number of function keys18
— Number of function keys with LEDs18
Keys with LEDYes
System keysYes
Numeric keyboardYes
alphanumeric keyboardYes
hexadecimal keyboardYes
Multi-key operationYes
— Number of multi-key operations2
Touch operation
Design as touch screenYes; analog, resistive
Connection type
Type of connection for mouse/keyboard/barcode readerUSB / USB / USB
Special operator controls
Stop buttonYes
Acknowledgement buttonYes
Key-operated switchYes
Illuminated pushbuttonYes; Two illuminated pushbuttons
HandwheelYes
Supply voltage
Design of the power supplyvia connection box
Type of supply voltageDC
Processor
Processor typeARM, 520 MHz
Memory
Type of memoryFlash / RAM
Memory available for user data6 Mbyte
Capacity of main memory, max.128 Mbyte
Accumulator
Buffer batteryYes; maximum buffer time 10 min
Time of day
Clock
Hardware clock (real-time)Yes
retentiveYes
synchronizableYes
Interfaces
Interfaces/bus type1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s)
Number of RS 485 interfaces1
Number of USB interfaces1
Number of wireless interfaces0
Multimedia card/SD card slot1 MMC/SD card slot
Protocols
Supports protocol for PROFINET IOYes
PROFIsafeNo
PROFIBUSYes
AS-InterfaceNo
Protocols (Ethernet)
TCP/IPYes
Further protocols
CANNo
Data-HighwayNo
DeviceNetNo
INTERBUSNo
Local Operating NetworkNo
MODBUSYes
SUCOnetNo
other bus systemsYes
Degree and class of protection
Degree of protection acc. to EN 60529IP65
Standards, approvals, certificates
CertificationsCE, cULus, C-TICK, SIBE
CE markYes
cULusYes
RCM (formerly C-TICK)Yes
Suitable for safety functionsYes
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1d
Ambient conditions
Free fall
Fall height, max.1.2 m
Ambient temperature during operation
min.0 °C
max.40 °C
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Relative humidity
Operation, max.80 %
Operating systems
pre-installed operating systemWindows CE
Configuration
Message indicatorYes
Alarm system (incl. buffer and acknowledgment)Yes
Process value display (output)Yes
Process value default (input) possibleYes
Recipe managementYes
Configuration software
Configuration toolWinCC flexible Standard Version 2005 SP1 or higher (to be ordered separately)
WinCC flexible CompactNo
WinCC flexible StandardYes
WinCC flexible AdvancedYes
WinCC Basic (TIA Portal)No
WinCC Comfort (TIA Portal)Yes
WinCC Advanced (TIA Portal)Yes
WinCC Professional (TIA Portal)Yes
Languages
Online languages
Number of online/runtime languages16
Project languages
Languages per project32
Functionality under WinCC (TIA Portal)
LibrariesYes
Applications/optionsInternet Explorer, Sm@rtService, Sm@rtAccess
Connection point identificationYes
Number of Visual Basic ScriptsYes
Task plannerYes
Help systemYes
Number of characters per info text70
Message system
Number of alarm classes32
Number of messages4 000
Bit messagesYes
— Number of bit messages4 000
Analog messagesYes
— Number of analog messages4 000
System messages HMIYes
System messages PLCYes
System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)Yes
Lines1
Number of characters per message80
Number of process values per message8
Acknowledgment groups
— Number of acknowledgement groups99
Message indicatorYes
First/last valueYes
Recipe management
Number of recipes300
Data records per recipe500
Entries per data record1 000
Recipe memory64 KB integrated Flash, expandable
Variables
Number of variables per device2 048
Number of variables per screen200
Number of variables1 000
Initial values2 048
Type Date & Time2 048
Limit valuesYes
MultiplexingYes
StructuresYes
Images
Number of configurable images500
Permanent window/defaultYes
Start screen configurableYes
Image selection by PLCYes
Image number in the PLCYes
Image objects
Text objects10,000 text elements
Number of I/O fields per image200
Number of date/time fields200
ReturnYes
Graphics objectBit maps, icons, vector graphics
— Icons1 000
Complex image objects
Status/controlYes; With SIMATIC S7
dynamic objectsDiagrams, bar graphs, sliders, analog display, invisible buttons
— Number of objects per project1 000
— Number of curve diagrams per image10
MethodsTrend / profile
Bar graphs
— Number of bars per chart10
Sliders
— Number of slides per image10
Pointer instruments
— Number of analog indicators per image10
Limit value linesYes
Number of alphanumerical fields300
— alphanumeric fields per image200
Number of numerical fields2 048
— numerical fields per image200
Number of password fields2 048
Number of visible switches per project200
— visible switches per image200
— hidden switches per image200
Number of status switches per project200
— Number of status switches per image200
Number of selector switches per project200
— Selector switches per image200
Number of decade switches per project200
— Decade switches per image200
Number of signal lamps per project200
— Signal lamps per image200
Attributes for dynamic objects
Color changeYes
X/Y movementYes
HideYes
Lists
Number of text lists per project500
Number of text lists per image200
Number of entries per text list256
Number of graphics lists per project400
Number of graphic lists per image200
Number of entries per graphics list256
Archiving
Number of archives per device20
Number of measuring points per project20
Number of entries per archive10 000
Message archiveYes
Process value archiveYes
Archiving methods
— Sequential archiveYes
— Short-term archiveYes
Memory locationMultiMediaCard
Data storage format
— CSVYes
Online evaluation
— using trend curvesYes
Filters
cyclicYes
ToleranceYes
ChangeYes
Security
Number of user groups50
Number of user rights32
Password export/importYes
Logging through printer
Recording/PrintingAlarms, report (shift report), color print, hardcopy
Transfer (upload/download)
Transfer of configurationMPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition
Process coupling
Connection to controllerS5, S7-200, S7-300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces"
S7-1200Yes
S7-1500Yes
S7-200Yes
— PPI (point-to-point)Yes
— PPI networkYes
— MPIYes
— PROFIBUS DPYes
— EthernetYes
S7-300/400Yes
— MPIYes
— PROFIBUS DPYes
— PROFINETYes
S5Yes
— serialYes
— PROFIBUS DPYes
TI 505Yes
Allen Bradley (DF1)Yes
Allen Bradley (DF485)Yes
Mitsubishi (FX)Yes
Mitsubishi (MP4)Yes
OMRON (LINK/Multilink)Yes
Modicon (Modbus)Yes
GE-Fanuc (SNP)Yes
Functions
TAB sequenceYes
Calculating functionsYes
AnimateYes
Service tools/configuration aids
Clean screenYes
Touch calibrationYes
Backup/Restore manuallyYes
SimulationYes
Device switchoverYes
Delta transferYes
Peripherals/Options
PeripheralsPrinter, barcode reader
SIMATIC HMI MM memory card: Multi Media CardYes
SIMATIC HMI SD memory card: Secure Digital memory cardYes
USB memoryYes
Additional software components loadableYes
Mechanics/material
Enclosure material (front)plastic
Dimensions
Enclosure diameter290 mm
Depth of housing103 mm
Weights
Weight (without packaging)1.7 kg
Other
free hotlineYes
last modified:03/28/2019