6AV6641-0CA01-0AX1
Operator Panel OP77B (2C)

From SIEMENS

The new part, as of 01.01.2015, is blocked for delivery. Spare part can continue to be purchased as required, but price may deviate from new part. Further information under SIMATIC current entry ID: 109486162. For questions, the familiar contact persons are available to you. SIMATIC Operator Panel OP 77B LC display backlit, 4.5" display graphics-capable, MPI/PROFIBUS DP interface up to 12 MB, printer/USB interface, slot for MMC, configurable with WinCC flexible 2004 Compact
General information
Product type designationOP 77B
Customer-specific configurationNo
Display
Design of displaySTN
Screen diagonal4.5 in
Color displayNo
Number of colors2; Black/white
Resolution (pixels)
Horizontal image resolution160 Pixel
Vertical image resolution64 Pixel
Backlighting
MTBF backlighting (at 25 °C)100 000 h
Control elements
Control elementsMembrane keyboard
Keyboard fonts
Membrane keyboard
— user-definable label membrane keysYes
Function keysYes
— Number of function keys8
— Number of function keys with LEDs4
System keysYes
— Number of system keys23
Numeric keyboardYes
alphanumeric keyboardYes
hexadecimal keyboardYes
Multi-key operationYes
Touch operation
Design as touch screenNo
Connection type
Type of connection for mouse/keyboard/barcode reader- / - / -
Installation type/mounting
Mounting positionvertical
maximum permissible angle of inclination without external ventilation80°
Supply voltage
Type of supply voltageDC
Input current
Current consumption (rated value)0.2 A
Starting current inrush I²t0.5 A²·s
Processor
Processor typeARM
Memory
Type of memoryFlash / RAM
Memory available for user data1 000 kbyte
Type of output
Info LEDYes
Power LEDNo
Error LEDNo
Time of day
Clock
TypeSoftware clock, no battery backup
retentiveNo
synchronizableNo
Interfaces
Interfaces/bus type1x RS 232, 1x RS 422, 1x RS 485 (max. 12 Mbit/s)
Number of industrial Ethernet interfaces0
Number of RS 485 interfaces1
Number of RS 422 interfaces1
Number of USB interfaces1
Multimedia card/SD card slotcombined
Protocols
Supports protocol for PROFINET IONo
PROFIsafeNo
PROFIBUSYes
Protocols (Ethernet)
TCP/IPNo
Further protocols
EtherNet/IPNo
MODBUSNo
other bus systemsYes
Degree and class of protection
IP (at the front)IP65
NEMA (front)NEMA 4x, NEMA 12 (when installed)
IP (rear)IP20
Standards, approvals, certificates
CertificationsCE, GL, ABS, BV, DNV, LRS, FM Class I Div. 2, UL, CSA, cULus, EX-Zone 2 (in Vorbereitung), EX-Zone 22 (in Vorbereitung), C-TICK, NEMA 4x, NEMA 12
cULusYes
EAC (formerly Gost-R)No
Suitable for safety functionsNo
Use in hazardous areas
ATEX Zone 2Yes
ATEX Zone 22Yes
FM Class I Division 2Yes
Marine approval
Germanischer Lloyd (GL)Yes
American Bureau of Shipping (ABS)Yes
Bureau Veritas (BV)Yes
Det Norske Veritas (DNV)Yes
Lloyds Register of Shipping (LRS)Yes
Nippon Kaiji Kyokai (Class NK)Yes
Polski Rejestr Statkow (PRS)No
Ambient conditions
Ambient temperature during operation
min.0 °C
max.50 °C
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Relative humidity
Operation, max.90 %
Operating systems
pre-installed operating systemWindows CE
Configuration
Message indicatorYes
Alarm system (incl. buffer and acknowledgment)Yes
Process value display (output)Yes
Process value default (input) possibleYes
Recipe managementYes
Configuration software
Configuration toolWinCC flexible Compact Version 2004 or higher (to be ordered separately)
STEP 7 Basic (TIA Portal)No
STEP 7 Professional (TIA Portal)No
WinCC flexible CompactYes
WinCC flexible StandardYes
WinCC flexible AdvancedYes
WinCC Basic (TIA Portal)No
WinCC Comfort (TIA Portal)Yes
WinCC Advanced (TIA Portal)Yes
WinCC Professional (TIA Portal)Yes
Languages
Online languages
Number of online/runtime languages5
Project languages
Languages per project32
Functionality under WinCC (TIA Portal)
LibrariesYes
Task plannerYes
Help systemYes
Number of characters per info text320
Message system
Number of alarm classes32
Number of messages1 000
Bit messagesYes
— Number of bit messages1 000
Analog messagesYes
— Number of analog messages1 000
Telegram message procedure Alarm SYes
System messages HMIYes
System messages PLCYes
System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)No
Number of characters per message80
Number of process values per message8
Acknowledgment groupsYes
Message indicatorNo
acoustic feedbackNo
First/last valueYes
Recipe management
Number of recipes100
Data records per recipe200
Entries per data record200
Recipe memory32 KB integrated Flash, expandable
Variables
Number of variables per device1 000
Number of variables per screen30
Limit valuesYes
MultiplexingYes
Images
Number of configurable images500
Permanent window/defaultYes
Start screen configurableYes
Image selection by PLCYes
Image number in the PLCYes
Image objects
Text objects2,500 text elements
Number of I/O fields per image30
Number of date/time fields0
Index of screen contextNo
ReturnYes
Graphics objectBit maps, icons, icon (full-screen)
— Icons1 000
— Icon (full screen)100
Complex image objects
dynamic objectsBar graphs
Bar graphs
— Number of bars per chart5
Pointer instruments
— Number of analog indicators per image0
Limit value linesYes
Number of alphanumerical fields1 000
— alphanumeric fields per image30
Number of numerical fields1 000
— numerical fields per image30
Number of password fields0
Number of visible switches per project
— visible switches per image0
— hidden switches per image0
Number of status switches per project
— Number of status switches per image0
Number of selector switches per project
— Selector switches per image0
Number of decade switches per project
— Decade switches per image0
Number of signal lamps per project
— Signal lamps per image0
Attributes for dynamic objects
Color changeYes
X/Y movementNo
HideYes
Angle of rotationNo
Lists
Number of text lists per project300
Number of graphics lists per project0
Number of graphic lists per image0
Number of entries per graphics list0
Security
Number of user groups50
Number of user rights32
Password export/importYes
Logging through printer
Recording/PrintingAlarms, report (shift report), hardcopy
Transfer (upload/download)
Transfer of configurationMPI/PROFIBUS DP, serial, USB, by means of external storage medium, automatic transfer recognition
Process coupling
Connection to controllerS5, S7-200, S7-300/400, TI 505, Win AC, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces"
S7-200Yes
— PPI (point-to-point)Yes
— PPI networkYes
— MPIYes
— PROFIBUS DPYes
— EthernetNo
S7-300/400Yes
— MPIYes
— PROFIBUS DPYes
— PROFINETNo
S5Yes
— serialYes
— PROFIBUS DPYes
TI 505Yes
Allen Bradley (DF1)Yes
Allen Bradley (DF485)Yes
Mitsubishi (FX)Yes
Mitsubishi (MP4)Yes
Telemecanique (ADJUST)No
Telemecanique (Uni-Telway)Yes; Only in combination with WinCC flexible
OMRON (LINK/Multilink)Yes
Modicon (Modbus)Yes
GE-Fanuc (SNP)Yes
Functions
Key repeatYes
TAB sequenceYes
Calculating functionsYes
AnimateYes
Menu tree editorYes
Unit switchoverNo
Service tools/configuration aids
Clean screenNo
Touch calibrationNo
Backup/Restore manuallyYes
SimulationYes
Device switchoverYes
Delta transferYes
Monitoring function for battery and memoryNo
Trace (operation archive)No
Expandability/openness
Open Platform ProgramNo
Peripherals/Options
PeripheralsPrinter
SIMATIC HMI MM memory card: Multi Media CardYes
Additional software components loadableYes
Dimensions
Width of the housing front150 mm
Height of housing front186 mm
Mounting cutout, width135 mm
Mounting cutout, height171 mm
Overall depth38.5 mm
Weights
Weight (without packaging)0.5 kg
Other
free hotlineYes