| ***SPARE PART*** SINVERT PVS COMBINERBOX 108, ARRAY JUNCTION BOX FOR PV, 8 DC INPUTS, IP54, IEC, WITH FUSE HOLDER, OVERLOAD PROTECTION |
General technical data: |
Product brand name | | SINVERT |
Product type designation | | SINVERT PVS Combiner Box 108 |
Product designation | | Terminal box |
Type of installation | | indoor installation / outdoor installation |
Protection class IP | | IP54 |
Operating resource protection class | | II (protective insulation) |
Degree of pollution | | 3 |
Installation altitude at height above sea level maximum | m | 2 000 |
Ambient temperature | | |
during operation | °C | -20 ... +45 |
during storage | °C | -20 ... +45 |
during transport | °C | -20 ... +45 |
Relative humidity without condensation during operation | % | 0 ... 50 |
RAL color number | | RAL 7035 |
Material | | |
of the enclosure box | | Polyester |
of the enclosure cover | | Polyester |
Product feature resistant to UV radiation | | Yes |
Burning behavior non-flammable | | Yes |
Product function Current measurement | | No |
Product component pressure compensation element | | Yes |
Number of pressure compensation elements | | 1 |
Type of compensation element | | Diaphragm |
Product function Overvoltage protection | | Yes |
Design of the overvoltage protection | | Type 2 |
Inputs: |
Input voltage maximum | V | 1 000 |
Number of inputs | | 8 |
Input current per input maximum | A | 10 |
Product component at input Protection | | Yes |
Fuse protection type at input | | Cylinder fuse link |
Number of inputs per fuse | | 1 |
Outputs: |
Output current maximum | A | 104 |
Product component at output Protection | | No |
Product component at output Circuit breaker | | No |
Connections/ Terminals: |
Type of electrical connection at DC input | | Cage clamp terminal |
Tightening torque at DC input | N·m | 2 ... 2.5 |
Connectable conductor cross-section at DC input | | |
finely stranded | mm² | 0.75 ... 25 |
— with core end processing | mm² | 1.5 ... 25 |
stranded | mm² | 0.75 ... 25 |
— with core end processing | mm² | 1.5 ... 25 |
Outer diameter of cable sheath at DC input at DC output can be used | mm | 4.5 ... 10 |
Type of electrical connection at DC output | | Stud terminal |
Design of the thread of the connection screw at DC output | | M8 |
Tightening torque at DC output | N·m | 6 ... 12 |
Connectable conductor cross-section at DC output | | |
finely stranded with core end processing | mm² | 2.5 ... 95 |
stranded with core end processing | mm² | 2.5 ... 95 |
Outer diameter of cable sheath at DC output at DC output can be used | mm | 15 ... 21 |
Type of electrical connection for grounding | | Cage clamp terminal |
Tightening torque for grounding | N·m | 1.2 ... 2.4 |
Connectable conductor cross-section for grounding | | |
finely stranded | mm² | 1.5 ... 16 |
— with core end processing | mm² | 1.5 ... 16 |
stranded | mm² | 1.5 ... 25 |
— with core end processing | mm² | 1.5 ... 16 |
Outer diameter of cable sheath for grounding at DC output can be used | mm | 4.5 ... 10 |
Installation/ mounting/ dimensions: |
Mounting position | | vertical |
Mounting type | | wall mounting |
Cable entry type | | from below |
Width | mm | 600 |
Depth | mm | 132 |
Height | mm | 400 |
Weight | kg | 10.5 |