6AG1642-0BC01-4AX1
SIPLUS TP177B mono DP

From SIEMENS

***Spare part*** as of 01.01.2015 the product is blocked for delivery and can no longer be ordered as a new part. For information on the successor See FAQ Entry ID: 82203106. For further questions, the familiar contact partners are available. . SIPLUS HMI TP 177B mono DP for medial exposure based on 6AV6642-0BC01-1AX1
General information
Product type designationTP 177B Bluemode
Customer-specific configurationYes
Display
Design of displaySTN
Screen diagonal5.7 in
Color displayNo
Number of colors4; Blue levels
Resolution (pixels)
Horizontal image resolution320 Pixel
Vertical image resolution240 Pixel
Backlighting
MTBF backlighting (at 25 °C)50 000 h
Control elements
Control elementsTouch screen
Keyboard fonts
System keysYes
Numeric keyboardYes
alphanumeric keyboardYes
hexadecimal keyboardYes
Multi-key operationNo
Touch operation
Design as touch screenYes; analog, resistive
Connection type
Type of connection for mouse/keyboard/barcode readerUSB / USB / USB
Installation type/mounting
Mounting positionvertical
maximum permissible angle of inclination without external ventilation35°
Supply voltage
Type of supply voltageDC
Input current
Current consumption (rated value)0.24 A
Starting current inrush I²t0.5 A²·s
Processor
Processor typeARM, 200 MHz
Memory
Type of memoryFlash / RAM
Memory available for user data2 048 kbyte
Time of day
Clock
TypeHardware clock, synchronizable, no battery backup
retentiveNo
synchronizableYes
Interfaces
Interfaces/bus typeRS 232 optional, 1x RS 422, 1x RS 485 (max. 12 Mbit/s)
Number of industrial Ethernet interfaces0
Number of RS 485 interfaces1
Number of RS 422 interfaces1
Number of USB interfaces1
PC card slotNo
CF card slotNo
Multimedia card/SD card slotcombined
Protocols
Protocols (terminal link)
Sm@rtServerYes
Degree and class of protection
IP (at the front)IP65
IP (rear)IP20
Standards, approvals, certificates
CertificationsCE
cULusNo
EAC (formerly Gost-R)No
Suitable for safety functionsNo
Use in hazardous areas
ATEX Zone 2No
ATEX Zone 22No
FM Class I Division 2No
Marine approval
Germanischer Lloyd (GL)No
American Bureau of Shipping (ABS)No
Bureau Veritas (BV)No
Det Norske Veritas (DNV)No
Lloyds Register of Shipping (LRS)No
Polski Rejestr Statkow (PRS)No
Ambient conditions
Ambient temperature during operation
min.0 °C
max.50 °C
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Altitude during operation relating to sea level
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
Operation, max.100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Operating systems
pre-installed operating systemWindows CE
Configuration
Message indicatorYes
Alarm system (incl. buffer and acknowledgment)Yes
Process value display (output)Yes
Process value default (input) possibleYes
Recipe managementYes
Configuration software
Configuration toolWinCC flexible Compact Version 2005 or higher (to be ordered separately)
Languages
Online languages
Number of online/runtime languages5
Project languages
Languages per project32
Functionality under WinCC (TIA Portal)
LibrariesYes
Task plannerYes
Help systemYes
Number of characters per info text70
Message system
Number of alarm classes32
Number of messages2 000
Bit messagesYes
— Number of bit messages2 000
Analog messagesYes
— Number of analog messages50
Telegram message procedure Alarm SNo
System messages HMIYes
System messages PLCYes
System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)No
Lines1
Number of characters per message80
Number of process values per message8
Acknowledgment groups
— Number of acknowledgement groups99
Message indicatorYes
acoustic feedbackNo
First/last valueYes
Recipe management
Number of recipes100
Data records per recipe200
Entries per data record200
Recipe memory32 KB integrated Flash, expandable
Variables
Number of variables per device1 000
Number of variables per screen50
Number of variables1 000
Initial values1 000
Type Date & Time1 000
Limit valuesYes
MultiplexingYes
StructuresNo
Images
Number of configurable images500
Permanent window/defaultYes
Start screen configurableYes
Image selection by PLCYes
Image number in the PLCYes
Image objects
Text objects2,500 text elements
Number of I/O fields per image50
Number of date/time fields30
Index of screen contextNo
ReturnYes
Graphics objectBit maps, icons, icon (full-screen), vector graphics
— Icons500
— Icon (full screen)50
Complex image objects
Status/controlWith SIMATIC S7
dynamic objectsDiagrams, bar graphs, sliders, analog display, invisible buttons
— Number of objects per project500
— Number of curve diagrams per image5
MethodsTrend
Bar graphs
— Number of bars per chart5
Sliders
— Number of slides per image0
Pointer instruments
— Number of analog indicators per image0
Limit value linesYes
Number of alphanumerical fields1 000
— alphanumeric fields per image100
Number of numerical fields1 000
— numerical fields per image100
Number of password fields1 000
Number of visible switches per project1 000
— visible switches per image100
— hidden switches per image100
Number of status switches per project1 000
— Number of status switches per image100
Number of selector switches per project1 000
— Selector switches per image100
Number of decade switches per project0
— Decade switches per image0
Number of signal lamps per project1 000
— Signal lamps per image100
Attributes for dynamic objects
Color changeYes
X/Y movementYes
HideYes
Angle of rotationNo
Lists
Number of text lists per project300
Number of text lists per image10
Number of entries per text list30
Number of graphics lists per project100
Number of graphic lists per image10
Number of entries per graphics list30
Security
Number of user groups50
Number of user rights32
Password export/importYes
Data carrier support
PC cardNo
CF cardNo
Logging through printer
Recording/PrintingAlarms, report (shift report), hardcopy
Transfer (upload/download)
Transfer of configurationMPI/PROFIBUS DP, serial, USB, by means of external storage medium, automatic transfer recognition
Process coupling
Connection to controllerS5, S7-200, S7- 300/400, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Mitsubishi (FX), Telemecanique (ADJUST), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces"
S7-200Yes
— PPI (point-to-point)Yes
— PPI networkNo
— MPIYes
— PROFIBUS DPYes
— EthernetNo
S7-300/400Yes
— MPIYes
— PROFIBUS DPYes
— PROFINETNo
S5Yes; only PROFIBUS DP
— serialNo
— PROFIBUS DPYes
TI 505No
Allen Bradley (DF1)Yes
Allen Bradley (DF485)No
Mitsubishi (FX)Yes
Telemecanique (ADJUST)Yes
OMRON (LINK/Multilink)No
Modicon (Modbus)Yes
Functions
Key repeatNo
TAB sequenceYes
Calculating functionsYes
AnimateYes
Menu tree editorYes
Unit switchoverNo
Service tools/configuration aids
Clean screenYes
Touch calibrationYes
Backup/Restore manuallyYes
SimulationYes
Device switchoverYes
Delta transferYes
Monitoring function for battery and memoryNo
Trace (operation archive)No
Expandability/openness
Open Platform ProgramYes
Peripherals/Options
PeripheralsPrinter
SIMATIC HMI MM memory card: Multi Media CardYes
Additional software components loadableYes
Dimensions
Width of the housing front212 mm
Height of housing front156 mm
Overall depth44 mm
Weights
Weight (without packaging)0.8 kg
Other
free hotlineYes
last modified:03/13/2019