| SIPLUS S7-300 CPU 315F-2DP with conformal coating according to EN 50155 T1 Cat 1 Cl A/ B based on 6ES7315-6FF04-0ab0 . Fail-safe module with MPI Integr. power supply 24 V DC, Work memory 384 KB, 40 mm width, 2nd interface DP master/ slave Micro Memory Card required |
General information |
Engineering with |
Programming package | STEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 218 + Distributed Safety |
Supply voltage |
Rated value (DC) | |
24 V DC | Yes; A power supply according to EN 50155 shall be used |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
external protection for power supply lines (recommendation) | 2 A min. |
Mains buffering |
Mains/voltage failure stored energy time | 5 ms |
Repeat rate, min. | 1 s |
Input current |
Current consumption (rated value) | 850 mA |
Current consumption (in no-load operation), typ. | 150 mA |
Inrush current, typ. | 3.5 A |
I²t | 1 A²·s |
Power loss |
Power loss, typ. | 4.5 W |
Memory |
Work memory |
integrated | 384 kbyte |
expandable | No |
Size of retentive memory for retentive data blocks | 128 kbyte |
Load memory |
Plug-in (MMC) | Yes |
Plug-in (MMC), max. | 8 Mbyte |
Data management on MMC (after last programming), min. | 10 y |
Backup |
present | Yes; Guaranteed by MMC (maintenance-free) |
without battery | Yes; Program and data |
CPU processing times |
for bit operations, typ. | 0.05 µs |
for word operations, typ. | 0.09 µs |
for fixed point arithmetic, typ. | 0.12 µs |
for floating point arithmetic, typ. | 0.45 µs |
CPU-blocks |
Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB |
Number, max. | 1 024; Number range: 1 to 16000 |
Size, max. | 64 kbyte |
FB |
Number, max. | 1 024; Number range: 0 to 7999 |
Size, max. | 64 kbyte |
FC |
Number, max. | 1 024; Number range: 0 to 7999 |
Size, max. | 64 kbyte |
OB |
Description | see instruction list |
Size, max. | 64 kbyte |
Number of free cycle OBs | 1; OB 1 |
Number of time alarm OBs | 1; OB 10 |
Number of delay alarm OBs | 2; OB 20, 21 |
Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 |
Number of process alarm OBs | 1; OB 40 |
Number of DPV1 alarm OBs | 3; OB 55, 56, 57 |
Number of isochronous mode OBs | 1; OB 61 |
Number of startup OBs | 1; OB 100 |
Number of asynchronous error OBs | 5; OB 80, 82, 85, 86, 87 |
Number of synchronous error OBs | 2; OB 121, 122 |
Nesting depth |
per priority class | 16 |
additional within an error OB | 4 |
Counters, timers and their retentivity |
S7 counter |
Number | 256 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 255 |
— preset | Z 0 to Z 7 |
Counting range |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 999 |
IEC counter |
present | Yes |
Type | SFB |
Number | Unlimited (limited only by RAM capacity) |
S7 times |
Number | 256 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 255 |
— preset | No retentivity |
Time range |
— lower limit | 10 ms |
— upper limit | 9 990 s |
IEC timer |
present | Yes |
Type | SFB |
Number | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity |
retentive data area in total | All, 128 KB max. |
Flag |
Number, max. | 2 048 byte |
Retentivity available | Yes; MB 0 to MB 2 047 |
Retentivity preset | MB 0 to MB 15 |
Number of clock memories | 8; 1 memory byte |
Data blocks |
Retentivity adjustable | Yes; via non-retain property on DB |
Retentivity preset | Yes |
Local data |
per priority class, max. | 32 kbyte; Max. 2 KB per block |
Address area |
I/O address area |
Inputs | 2 048 byte |
Outputs | 2 048 byte |
of which distributed |
— Inputs | 2 048 byte |
— Outputs | 2 048 byte |
Process image |
Inputs | 2 048 byte |
Outputs | 2 048 byte |
Inputs, adjustable | 2 048 byte |
Outputs, adjustable | 2 048 byte |
Inputs, default | 384 byte |
Outputs, default | 384 byte |
Subprocess images |
Number of subprocess images, max. | 1 |
Digital channels |
Inputs | 16 384 |
— of which central | 1 024 |
Outputs | 16 384 |
— of which central | 1 024 |
Analog channels |
Inputs | 1 024 |
— of which central | 256 |
Outputs | 1 024 |
— of which central | 256 |
Hardware configuration |
Number of expansion units, max. | 3 |
Number of DP masters |
integrated | 1 |
via CP | 4 |
Number of operable FMs and CPs (recommended) |
FM | 8 |
CP, PtP | 8 |
CP, LAN | 10 |
Rack |
Racks, max. | 4 |
Modules per rack, max. | 8 |
Time of day |
Clock |
Hardware clock (real-time) | Yes |
retentive and synchronizable | Yes |
Backup time | 6 wk; At 40 °C ambient temperature |
Deviation per day, max. | 10 s; Typ.: 2 s |
Behavior of the clock following expiry of backup period | Clock continues to run with the time at which the power failure occurred |
Operating hours counter |
Number | 1 |
Number/Number range | 0 |
Range of values | 0 to 2^31 hours (when using SFC 101) |
Granularity | 1 h |
retentive | Yes; Must be restarted at each restart |
Clock synchronization |
supported | Yes |
to MPI, master | Yes |
to MPI, slave | Yes |
to DP, master | Yes; With DP slave only slave clock |
to DP, slave | Yes |
in AS, master | Yes |
Digital inputs |
Number of digital inputs | 0 |
Digital outputs |
Number of digital outputs | 0 |
Analog inputs |
Number of analog inputs | 0 |
Analog outputs |
Number of analog outputs | 0 |
Interfaces |
Number of industrial Ethernet interfaces | 0 |
Number of PROFINET interfaces | 0 |
Number of RS 485 interfaces | 2 |
Number of RS 422 interfaces | 0 |
1. Interface |
Interface type | Integrated RS 485 interface |
Physics | RS 485 |
Isolated | No |
Power supply to interface (15 to 30 V DC), max. | 200 mA |
Protocols |
MPI | Yes |
PROFIBUS DP master | No |
PROFIBUS DP slave | No |
Point-to-point connection | No |
MPI |
Transmission rate, max. | 187.5 kbit/s |
Services |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | Yes |
— S7 basic communication | Yes |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes |
2. Interface |
Interface type | Integrated RS 485 interface |
Physics | RS 485 |
Isolated | Yes |
Power supply to interface (15 to 30 V DC), max. | 200 mA |
Protocols |
MPI | No |
PROFIBUS DP master | Yes |
PROFIBUS DP slave | Yes |
Point-to-point connection | No |
PROFIBUS DP master |
Transmission rate, max. | 12 Mbit/s |
Number of DP slaves, max. | 124; Per station |
Services |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | Yes; I blocks only |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes |
— Equidistance | Yes |
— Isochronous mode | Yes; OB 61 |
— SYNC/FREEZE | Yes |
— Activation/deactivation of DP slaves | Yes |
— Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 |
— DPV1 | Yes |
Address area |
— Inputs, max. | 2 048 byte |
— Outputs, max. | 2 048 byte |
User data per DP slave |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
PROFIBUS DP slave |
GSD file | The latest GSD file is available at: http://www.siemens.com/profibus-gsd |
Transmission rate, max. | 12 Mbit/s |
automatic baud rate search | Yes; only with passive interface |
Address area, max. | 32 |
User data per address area, max. | 32 byte |
Services |
— PG/OP communication | Yes |
— Routing | Yes; Only with active interface |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes; Only server, configured on one side |
— S7 communication, as client | No |
— S7 communication, as server | Yes |
— Direct data exchange (slave-to-slave communication) | Yes |
— DPV1 | No |
Transfer memory |
— Inputs | 244 byte |
— Outputs | 244 byte |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) | Yes |
Communication functions |
PG/OP communication | Yes |
Data record routing | Yes |
Global data communication |
supported | Yes |
Number of GD loops, max. | 8 |
Number of GD packets, max. | 8 |
Number of GD packets, transmitter, max. | 8 |
Number of GD packets, receiver, max. | 8 |
Size of GD packets, max. | 22 byte |
Size of GD packet (of which consistent), max. | 22 byte |
S7 basic communication |
supported | Yes |
User data per job, max. | 76 byte |
User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
supported | Yes |
as server | Yes |
as client | Yes; Via CP and loadable FB |
User data per job, max. | 180 byte; With PUT/GET |
User data per job (of which consistent), max. | 240 byte; as server |
S5 compatible communication |
supported | Yes; via CP and loadable FC |
Number of connections |
overall | 16 |
usable for PG communication | 15 |
— reserved for PG communication | 1 |
— adjustable for PG communication, min. | 1 |
— adjustable for PG communication, max. | 15 |
usable for OP communication | 15 |
— reserved for OP communication | 1 |
— adjustable for OP communication, min. | 1 |
— adjustable for OP communication, max. | 15 |
usable for S7 basic communication | 12 |
— reserved for S7 basic communication | 0 |
— adjustable for S7 basic communication, min. | 0 |
— adjustable for S7 basic communication, max. | 12 |
S7 message functions |
Number of login stations for message functions, max. | 16; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages | Yes |
simultaneously active Alarm-S blocks, max. | 300 |
Test commissioning functions |
Status block | Yes; Up to 2 simultaneously |
Single step | Yes |
Number of breakpoints | 4 |
Status/control |
Status/control variable | Yes |
Variables | Inputs, outputs, memory bits, DB, times, counters |
Number of variables, max. | 30 |
— of which status variables, max. | 30 |
— of which control variables, max. | 14 |
Forcing |
Forcing | Yes |
Forcing, variables | Inputs, outputs |
Number of variables, max. | 10 |
Diagnostic buffer |
present | Yes |
Number of entries, max. | 500 |
— adjustable | No |
— of which powerfail-proof | 100; Only the last 100 entries are retained |
Number of entries readable in RUN, max. | |
— adjustable | Yes; From 10 to 499 |
— preset | 10 |
Isolation |
Isolation tested with | 500V AC for 1 minute |
Standards, approvals, certificates |
CE mark | Yes |
UL approval | Yes; File E239877 |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
EAC (formerly Gost-R) | Yes |
Use in hazardous areas |
ATEX | Yes |
Railway application |
EN 50155 | Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B, EN 50155:2007 |
Ambient conditions |
Ambient temperature during operation |
min. | -25 °C; = Tmin |
max. | 60 °C; = Tmax; the rated temperature range of -25 ... +55 °C (T1) applies for the use on railway vehicles according to EN50155 |
Ambient temperature during storage/transportation |
min. | -40 °C |
max. | 70 °C |
Altitude during operation relating to sea level |
Installation altitude above sea level, max. | 2 000 m |
Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
Relative humidity |
With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance |
Use in stationary industrial systems |
— to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
— to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
— to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
Use on land craft, rail vehicles and special-purpose vehicles |
— to biologically active substances according to EN 60721-3-5 | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
— to chemically active substances according to EN 60721-3-5 | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); * |
— to mechanically active substances according to EN 60721-3-5 | Yes; Class 5S3 incl. sand, dust; * |
Remark |
— Note regarding classification of environmental conditions acc. to EN 60721 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
Configuration |
Configuration software |
STEP 7 | Yes; V5.2 SP1 or higher with HW update |
Programming |
Command set | see instruction list |
Nesting levels | 8 |
System functions (SFC) | see instruction list |
System function blocks (SFB) | see instruction list |
Programming language |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— CFC | Yes |
— GRAPH | Yes |
— HiGraph® | Yes |
Know-how protection |
User program protection/password protection | Yes |
Block encryption | Yes; With S7 block Privacy |
Dimensions |
Width | 40 mm |
Height | 125 mm |
Depth | 130 mm |
Weights |
Weight, approx. | 290 g |
last modified: | 03/13/2019 |