| circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=125...160A overload prot. II=800...1600A, short-circuit protection without auxiliary release without auxiliary/alarm switch |
Model |
Product brand name | SENTRON |
Product designation | 3VT1_5 molded case circuit breakers |
Design of the operating mechanism | toggle handle |
Type of the driving mechanism / motor drive | No |
Design of the overcurrent release | TM |
General technical data |
Number of poles | 3 |
Size of the circuit-breaker | 3VT1 |
Electrical endurance (switching cycles) / typical | 6 000 |
Usage category | A |
Performance class for circuit breaker | N |
Mechanical service life (switching cycles) / typical | 20 000 |
Operating frequency / maximum | 120 1/h |
Voltage |
Insulation voltage / rated value | 690 V |
Surge voltage resistance / rated value | 8 kV |
Protection class |
Protection class IP | IP40 |
Protective function of the overcurrent release | LI |
Dissipation |
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole | 5 W |
Electricity |
Operating current / at 45 °C / rated value | 145 A |
Continuous current / rated value | 160 A |
Derating temperature / for the rated value of the continuous current | 40 °C |
Adjustable pick-up value current | |
of the current-dependent overload release / Full-scale value | 160 A |
of instantaneous short-circuit trip unit / initial value | 800 A |
of instantaneous short-circuit trip unit / Full-scale value | 1 600 A |
Main circuit |
Operating frequency | |
1 / rated value | 50 Hz |
2 / rated value | 60 Hz |
Operating voltage | |
rated value / maximum | 690 V |
for main current circuit / at AC / at 50 Hz / maximum | 690 V |
for main current circuit / at AC / at 60 Hz / maximum | 690 V |
for main current circuit / at DC / maximum | 250 V |
Operating current | |
at 40 °C / rated value | 160 A |
at 50 °C / rated value | 145 A |
Auxiliary circuit |
Number of CO contacts / for auxiliary contacts | 0 |
Number of NC contacts / for auxiliary contacts | 0 |
Number of NO contacts / for auxiliary contacts | 0 |
Suitability |
Suitability for use | system protection |
Disconnecting means | Yes |
Adjustable parameters |
Adjustable pick-up value current / of the current-dependent overload release / initial value | 125 A |
Product details |
Product component | |
Trip indicator | No |
Auxiliary switch | No |
Voltage trigger | No |
undervoltage release | No |
undervoltage release with leading contact | No |
Product extension / optional / motor drive | Yes |
Product function |
Product function | |
of thermal overload trip unit | adjustable |
Ground fault protection | No |
for neutral conductors / Short-circuit and overload proof | No |
Phase failure detection | No |
Overload protection | Yes |
Short circuit |
Operational short-circuit current breaking capacity (Ics) | |
at 240 V / rated value | 20 kA |
at 415 V / rated value | 13 kA |
at 500 V / rated value | 6 kA |
at 690 V / rated value | 3 kA |
Maximum short-circuit current breaking capacity (Icu) | |
at 240 V / rated value | 40 kA |
at 415 V / rated value | 25 kA |
at 500 V / rated value | 12 kA |
at 690 V / rated value | 6 kA |
Connections |
Arrangement of electrical connectors / for main current circuit | front side |
Type of electrical connection / for main current circuit | box terminals |
Mechanical Design |
Height | 130 mm |
Width | 75 mm |
Depth | 80 mm |
Mounting position | with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back |
Mounting type | fixed mounting |
Net weight | 1.083 kg |
Environmental conditions |
Ambient temperature | |
during operation / minimum | -40 °C |
during operation / maximum | 55 °C |
during storage / minimum | -40 °C |
during storage / maximum | 55 °C |