3VA2040-6JQ46-0EG0
MCCB_IEC_FS100_40A_4P_85KA_ETU5_LSIG

From SIEMENS

CIRCUIT BREAKER 3VA2 IEC FRAME 100 BREAKING CAPACITY CLASS H ICU=85KA @ 415 V 4POLE, LINE PROTECTION ETU560, LSIG, IN=40A OVERLOAD PROTECTION IR=16A ...40A SHORT CIRCUIT PROTECTION ISD=0,6..10X IN, II=1,5..12X IN NEUTRAL PROTECTION ADJUSTABLE (OFF, UPTO 160%) GROUNDFAULT, SWITCHABLE IG=0,4... 1 X IN, TG=0,05-0,8S CABLE CONNECTION UNDERVOLTAGE RELEASE (LNO) 24 V DC 1 AUXILIARY SWITCH 1 TRIP ALARM SWITCH
Model
Product brand nameSENTRON
Product designationMolded case circuit breaker
Product versionLine protection
Design of the overcurrent releaseETU560
Protective function of the overcurrent releaseLSIG
Number of poles4
Design of the auxiliary releaseUndervoltage release with leading NO contacts (UVR(LNO))
Auxiliary contact version1 auxiliary switch + 1 trip alarm switch HP
General technical data
Rated insulation voltage Ui800 V
Max. rated operational voltage Ue with AC 50/60Hz690 V
Power loss [W] / maximum3 W
Latching - endurance20 000
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz12 000
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz1 500
Neutral conductors / upgradeable/retrofittableNo
Ground fault monitoring versionSummation current formation L + N conductor
Product function
communication functionYes
Phase failure detectionNo
other measurement functionNo
Net weight3 140 g
Current
Max. rated operational current of the frame size100 A
Rated continuous current Iu40 A
Operating current
at 40 °C40 A
at 45 °C40 A
at 50 °C40 A
at 55 °C38.5 A
at 60 °C37 A
at 65 °C35.5 A
at 70 °C34 A
Switching capacity according to IEC 60947
Switching capacity class of the circuit breakerH
Maximum short-circuit current breaking capacity (Icu)
at 240 V110 kA
at 415 V85 kA
at 690 V2 kA
Operational short-circuit current breaking capacity (Ics)
at 240 V110 kA
at 415 V85 kA
at 690 V2 kA
Short-circuit current making capacity (Icm)
at 240 V242 kA
at 415 V187 kA
at 690 V3 kA
Adjustable parameters
Adjustable response value current / lr min.0.4 A
Adjustable response value current / Ir max.1 A
Adjustable response value time / tr min.0.5
Adjustable response value time / tr max.25
Adjustable response value current / Isd min.0.6 A
Adjustable response value current / Isd max.10 A
Short-term delayed / tripping switchable / I2t=ON/OFFYes
Adjustable response value time / tsd min.0.05 s
Adjustable response value time / tsd max.0.5 s
Adjustable response value time / tsd min.0.05 s
Adjustable response value time / tsd max.0.5 s
Adjustable response value current / li min.1.5 A
Ground fault protection can be switched ON/OFFYes
Adjustable response value current / lg min.0.4 A
Adjustable response value current / lg max.1 A
Adjustable response value current / tg min.0.05 s
Adjustable response value current / tg max.0.8 s
Adjustable response value current / for G-tripping / with I2t characteristic / min.0.4 A
Adjustable response value current / for G-tripping / with I2t characteristic / max.1 A
Mechanical Design
Height181 mm
Width140 mm
Depth107 mm
Connections
Arrangement of electrical connectors / for main current circuitFront terminal
Type of electrical connection / for main current circuitbox terminal
Type of connectable conductor cross-section, round conductor terminal, stranded1 x (6-120 mm²)
Auxiliary circuit
Product component
undervoltage releaseNo
Voltage triggerNo
undervoltage release with leading contactYes
Trip indicatorYes
Number of CO contacts / for auxiliary contacts2
Accessories
Product extension / optional / motor driveYes
Manufacturer's article number
of the supplied basic switch
of the integrated auxiliary switch/alarm switch
of the integrated auxiliary switch/alarm switch
of the integrated auxiliary trip3VA9908-0BC11
Environmental conditions
Protection class IP / on the frontIP40
Ambient temperature
during operation / minimum-25 °C
during operation / maximum70 °C
during storage / minimum-40 °C
during storage / maximum80 °C