| Safety position switch with tumbler Locking force 1300 N 5 directions of approaches Plastic enclosure, M12 connector ASIsafe integrated Channel 1=actuator 2 NC According to principle of 2v2 evaluation Channel 2=magnet 1 NC spring-locked Escape release on the front Magnet voltage 24 V DC/AC Monitoring actuator 2 NC/1 NO Monitoring magnet 2 NC/1 NO The matching separate Actuator 3SE5000-0AV0 must be ordered separately |
Product brand name | SIRIUS |
Product designation | Mechanical safety switches |
Design of the product | with separate actuator and with tumbler |
Product type designation | 3SF13 |
Manufacturer's article number | |
of the optional actuators | 3SE5000-0AV01 standard actuator, 3SE5000-0AV02 actuator with vertical mounting, 3SE5000-0AV03 actuator with transverse mounting, 3SE5000-0AV04 radius actuator left, 3SE5000-0AV05 universal actuator, 3SE5000-0AV06 radius actuator right, 3SE5000-0AV07 heavy duty actuator |
Suitability for use safety switch | Yes |
General technical data |
Product function | |
positive opening | Yes |
Insulation voltage | |
rated value | 30 V |
Degree of pollution | class 3 |
Surge voltage resistance rated value | 0.8 kV |
Protection class IP | IP65/IP67 |
Shock resistance | 30g / 11 ms |
acc. to IEC 60068-2-27 | 30 g / 11 ms |
Vibration resistance | 0.35 mm / 5g |
acc. to IEC 60068-2-6 | 0.35 mm/5g |
Mechanical service life (switching cycles) | |
typical | 1 000 000 |
Material of the enclosure of the switch head | plastic |
Locking force | 1 300 N |
acc. to DIN EN ISO 14119 | 1 000 N |
Repeat accuracy | 0.1 mm |
Minimum actuating force in activation direction | 30 N |
Enclosure |
Design of the housing | special design |
Material of the enclosure | plastic |
Design of the housing acc. to standard | No |
Drive Head |
Design of the operating mechanism | 5 directions of approach |
Design of the switching function | positive opening |
Number of actuation directions | 5 |
Connections/Terminals |
Type of electrical connection | M12 plug, fixed |
Safety related data |
B10 value | |
with high demand rate acc. to SN 31920 | 1 000 000 |
Proportion of dangerous failures | |
with high demand rate acc. to SN 31920 | 20 % |
Design of plug-in connection | M12 plug, 4-pole: Pin 1 = ASI+ , Pin 2 = not assigned, Pin 3= ASI-, Pin 4 = not assigned |
Locking mechanism design | spring-actuated lock (closed-circuit principle) escape release from the front |
Communication/ Protocol |
Design of the interface | M12 plug, fixed |
AS interface slave profile | 7.B.F |
ID1 code | F (hex, variable 0...F) |
Ambient conditions |
Ambient temperature | |
during operation | -25 ... +60 °C |
during storage | -40 ... +80 °C |
Supply voltage |
Supply voltage of magnet coil | 24 V |
Installation/ mounting/ dimensions |
Mounting position | any |
Mounting type | screw fixing |