3SF1324-1SF21-1BA1
POS.SW.W.ASISAFE ELECTR.INT.,PLAST.ENCL.

From SIEMENS

Safety position switch with tumbler Locking force 1300 N 5 directions of approaches Plastic enclosure, M12 connector ASIsafe integrated Channel 1=actuator 1 NC Channel 2=magnet 1 NC spring-locked Escape release on the front Magnet voltage 24 V DC/AC Monitoring actuator 2 NC/1 NO Monitoring magnet 2 NC/1 NO The matching separate Actuator 3SE5000-0AV0 must be ordered separately
Product brand nameSIRIUS
Product designationMechanical safety switches
Design of the productwith separate actuator and with tumbler
Product type designation3SF13
Manufacturer's article number
of the optional actuators3SE5000-0AV01 standard actuator, 3SE5000-0AV02 actuator with vertical mounting, 3SE5000-0AV03 actuator with transverse mounting, 3SE5000-0AV04 radius actuator left, 3SE5000-0AV05 universal actuator, 3SE5000-0AV06 radius actuator right, 3SE5000-0AV07 heavy duty actuator
Suitability for use safety switchYes
General technical data
Product function
positive openingYes
Insulation voltage
rated value30 V
Degree of pollutionclass 3
Surge voltage resistance rated value0.8 kV
Protection class IPIP65/IP67
Shock resistance30g / 11 ms
acc. to IEC 60068-2-2730 g / 11 ms
Vibration resistance0.35 mm / 5g
acc. to IEC 60068-2-60.35 mm/5g
Mechanical service life (switching cycles)
typical1 000 000
Material of the enclosure of the switch headplastic
Locking force1 300 N
acc. to DIN EN ISO 141191 000 N
Repeat accuracy0.1 mm
Minimum actuating force in activation direction30 N
Enclosure
Design of the housingspecial design
Material of the enclosureplastic
Design of the housing acc. to standardNo
Drive Head
Design of the operating mechanism5 directions of approach
Design of the switching functionpositive opening
Number of actuation directions5
Connections/Terminals
Type of electrical connectionM12 plug, fixed
Safety related data
B10 value
with high demand rate acc. to SN 319201 000 000
Proportion of dangerous failures
with high demand rate acc. to SN 3192020 %
Design of plug-in connectionM12 plug, 4-pole: Pin 1 = ASI+ , Pin 2 = not assigned, Pin 3= ASI-, Pin 4 = not assigned
Locking mechanism designspring-actuated lock (closed-circuit principle) escape release from the front
Communication/ Protocol
Design of the interfaceM12 plug, fixed
AS interface slave profile7.B.F
ID1 codeF (hex, variable 0...F)
Ambient conditions
Ambient temperature
during operation-25 ... +60 °C
during storage-40 ... +80 °C
Supply voltage
Supply voltage of magnet coil24 V
Installation/ mounting/ dimensions
Mounting positionany
Mounting typescrew fixing

External links