| ENCLOSURE FOR COMMAND DEVICES, 22MM, ROUND, ENCLOSURE MATERIAL PLASTIC, YELLOW ENCLOSURE TOP PART, WITH PROTECTIVE COLLAR, 1 COMMAND POINT, A=EM. STOP MUSHROOM PUSHB. RED, 40MM, ROTATE-TO-UNLATCH, 1NC, SCREW TERMINAL, FLOOR MOUNTING, TOP AND BOTTOM 1 X M20 EACH !!! Phased-out product !!! SIRIUS ACT 3SU1 is successor Preferred successor type is >>3SU1801-0NA00-2AC2<< |
| Enclosure |
| Design of the housing | Enclosure for command and signaling devices with standard equipment |
| Shape of the enclosure front | Square |
| Material of the enclosure | plastic |
| Number of command points | 1 |
| Product component | |
| protective collar | Yes |
| Color | |
| of top part of the enclosure | yellow |
| Delivery state | |
| as a kit | No |
| pre-wired on strip terminal | No |
| Mounting type of the enclosure | Vertical / horizontal |
| Actuator |
| Design of the operating mechanism | Emergency stop mushroom pushbutton |
| Product feature | |
| lockout | No |
| Product extension optional Light source | No |
| Color | |
| of the actuating element | Red |
| Material of the actuating element | plastic |
| Type of unlocking device | rotate-to-unlatch mechanism |
| Front ring |
| Product component front ring | No |
| Holder |
| Material of the holder | Plastic |
| Contact block/ lampholder |
| Number of lampholders | 0 |
| Number of switching elements | 1 |
| General technical data |
| Product function | |
| positive opening | Yes |
| EMERGENCY OFF function | Yes |
| EMERGENCY STOP function | Yes |
| Product component | |
| Light source | No |
| Stand/pedestal | No |
| Type of voltage | |
| of the operating voltage | AC/DC |
| Protection class IP | IP65 |
| Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | S |
| Reference code acc. to DIN EN 81346-2 | S |
| Reference code acc. to DIN EN 61346-2 | S |
| Operating voltage | |
| at AC | |
| — at 50 Hz rated value | 5 ... 400 V |
| — at 60 Hz rated value | 5 ... 300 V |
| at DC | |
| — rated value | 5 ... 230 V |
| Operating voltage 1 | |
| at AC | |
| — at 50 Hz rated value | 400 V |
| — at 60 Hz rated value | 300 V |
| at DC rated value | 230 V |
| Auxiliary circuit |
| Number of NC contacts for auxiliary contacts | 1 |
| Number of NO contacts for auxiliary contacts | 0 |
| Number of CO contacts | |
| for auxiliary contacts | 0 |
| Operating current at AC-12 | |
| at 24 V rated value | 10 A |
| at 48 V rated value | 10 A |
| at 110 V rated value | 10 A |
| at 230 V rated value | 10 A |
| at 400 V rated value | 10 A |
| Operating current at AC-15 | |
| at 24 V rated value | 6 A |
| at 48 V rated value | 6 A |
| at 110 V rated value | 6 A |
| at 230 V rated value | 6 A |
| at 400 V rated value | 3 A |
| Operating current at DC-12 | |
| at 24 V rated value | 10 A |
| at 48 V rated value | 5 A |
| at 110 V rated value | 2.5 A |
| at 230 V rated value | 1 A |
| Operating current at DC-13 | |
| at 24 V rated value | 3 A |
| at 48 V rated value | 1.5 A |
| at 110 V rated value | 0.7 A |
| at 230 V rated value | 0.3 A |
| Connections/Terminals |
| Type of electrical connection on enclosure | Cable routing above, below / left, right, each 1 x M20 |
| Tightening torque of the screws in the bracket | 1 ... 1.2 N·m |
| Safety related data |
| B10 value | |
| with high demand rate acc. to SN 31920 | 100 000 |
| Proportion of dangerous failures | |
| with low demand rate acc. to SN 31920 | 20 % |
| with high demand rate acc. to SN 31920 | 20 % |
| Failure rate [FIT] | |
| with low demand rate acc. to SN 31920 | 100 FIT |
| T1 value for proof test interval or service life acc. to IEC 61508 | 20 y |
| Ambient conditions |
| Ambient temperature | |
| during operation | -25 ... +70 °C |
| during storage | -40 ... +80 °C |
| Environmental category during operation acc. to IEC 60721 | 3K6 |
| Installation/ mounting/ dimensions |
| Mounting type | |
| of contact blocks, socket, and accessories | Floor mounting |
| Height | 85 mm |
| Width | 85 mm |
| Depth | 106 mm |
| Shape of the installation opening | round |
| Mounting diameter | 22 mm |
| Accessories |
| Number of labels | 0 |
| Number of backing plates | 0 |
| Product component holder for 3 switching elements | No |