| SIRIUS soft starter 200-690 V 93 A, 110-250 V AC Screw terminals |
| Product brand name | SIRIUS |
| Product category | Hybrid switching devices |
| Product designation | Soft starter |
| Manufacturer's article number | |
| of HMI-Modul high-feature usable | |
| of communication module PROFINET standard usable | |
| of communication module PROFIBUS usable | |
| of communication module Modbus TCP usable | |
| of circuit breaker usable at 400 V | |
| of circuit breaker usable at 500 V | |
| of circuit breaker usable at 400 V at inside-delta circuit | |
| of circuit breaker usable at 500 V at inside-delta circuit | |
| of the gG fuse usable up to 690 V | |
| of the gG fuse usable at inside-delta circuit up to 500 V | |
| of full range R fuse link for semiconductor protection usable up to 690 V | |
| of back-up R fuse link for semiconductor protection usable up to 690 V | |
| General technical data |
| Starting voltage [%] | 20 ... 100 % |
| Start-up ramp time of soft starter | 0 ... 360 s |
| Stopping time of soft starter | 0 ... 360 s |
| Start torque [%] | 10 ... 100 % |
| Stopping torque [%] | 10 ... 100 % |
| Torque limit [%] | 20 ... 200 % |
| Current limiting value [%] adjustable | 125 ... 800 % |
| Breakaway voltage [%] adjustable | 40 ... 100 % |
| Breakaway time adjustable | 0 ... 2 s |
| Number of parameter sets | 3 |
| Accuracy class acc. to IEC 61557-12 | 5 % |
| Product component | |
| HMI-High Feature | Yes |
| is supported HMI-High Feature | Yes |
| Product feature integrated bypass contact system | Yes |
| Number of controlled phases | 3 |
| Trip class | CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2 |
| Current unbalance limiting value [%] | 10 ... 60 % |
| Ground-fault monitoring limiting value [%] | 10 ... 95 % |
| Recovery time after overload trip adjustable | 60 ... 1 800 s |
| Insulation voltage | |
| rated value | 690 V |
| Impulse voltage rated value | 8 kV |
| Blocking voltage of the thyristor maximum | 1 800 V |
| Service factor | 1.15 |
| Surge voltage resistance rated value | 8 kV |
| maximum permissible voltage for safe isolation | |
| between main and auxiliary circuit | 690 V |
| Protection class IP | IP00 |
| Reference code acc. to DIN EN 81346-2 | Q |
| Product function | |
| ramp-up (soft starting) | Yes |
| ramp-down (soft stop) | Yes |
| breakaway pulse | Yes |
| Adjustable current limitation | Yes |
| creep speed in both directions of rotation | Yes |
| pump ramp down | Yes |
| DC braking | Yes |
| motor heating | Yes |
| slave pointer function | Yes |
| trace function | Yes |
| Intrinsic device protection | Yes |
| motor overload protection | Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) |
| Evaluation of thermistor motor protection | Yes; Type A PTC or Klixon / Thermoclick |
| inside-delta circuit | No |
| Auto-reset | Yes |
| Manual RESET | Yes |
| remote reset | Yes |
| communication function | Yes |
| operating measured value display | Yes |
| event list | Yes |
| error logbook | Yes |
| via software parameterizable | Yes |
| via software configurable | Yes |
| PROFIenergy | Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules |
| firmware update | Yes |
| removable terminal for control circuit | Yes |
| combined braking | Yes |
| analog output | Yes; 4 ... 20 mA (default) / 0 ... 10 V |
| programmable control input-/outputs | Yes |
| condition monitoring | Yes |
| automatic parameterisation | Yes |
| application wizards | Yes |
| alternative run-down | Yes |
| emergency operation mode | Yes |
| reversing operation | Yes |
| soft starting at heavy starting conditions | Yes |
| Power Electronics |
| Operating current | |
| at 40 °C rated value | 93 A |
| at 50 °C rated value | 82.5 A |
| at 60 °C rated value | 75.5 A |
| Operating current at inside-delta circuit | |
| at 40 °C rated value | 161 A |
| at 50 °C rated value | 143 A |
| at 60 °C rated value | 131 A |
| Operating voltage | |
| rated value | 200 ... 690 V |
| at inside-delta circuit rated value | 200 ... 600 V |
| Relative negative tolerance of the operating voltage | -15 % |
| Relative positive tolerance of the operating voltage | 10 % |
| Relative negative tolerance of the operating voltage at inside-delta circuit | -15 % |
| Relative positive tolerance of the operating voltage at inside-delta circuit | 10 % |
| Operating power for three-phase motors | |
| at 230 V at 40 °C rated value | 22 kW |
| at 230 V at inside-delta circuit at 40 °C rated value | 45 kW |
| at 400 V at 40 °C rated value | 45 kW |
| at 400 V at inside-delta circuit at 40 °C rated value | 90 kW |
| at 500 V at 40 °C rated value | 55 kW |
| at 500 V at inside-delta circuit at 40 °C rated value | 110 kW |
| at 690 V at 40 °C rated value | 90 kW |
| Operating frequency 1 rated value | 50 Hz |
| Operating frequency 2 rated value | 60 Hz |
| Relative negative tolerance of the operating frequency | -10 % |
| Relative positive tolerance of the operating frequency | 10 % |
| Adjustable motor current | |
| minimum | 19 A |
| at inside-delta circuit minimum | 32.9 A |
| Minimum load [%] | 10 %; Relative to set Ie |
| Power loss [W] for rated value of the current at AC | |
| at 40 °C to power-up | 28 W |
| at 50 °C to power-up | 25 W |
| at 60 °C to power-up | 23 W |
| Control circuit/ Control |
| Type of voltage of the control supply voltage | AC |
| Control supply voltage at AC | |
| at 50 Hz | 110 ... 250 V |
| at 60 Hz | 110 ... 250 V |
| Relative negative tolerance of the control supply voltage at AC at 50 Hz | -15 % |
| Relative positive tolerance of the control supply voltage at AC at 50 Hz | 10 % |
| Relative negative tolerance of the control supply voltage at AC at 60 Hz | -15 % |
| Relative positive tolerance of the control supply voltage at AC at 60 Hz | 10 % |
| Control supply voltage frequency | 50 ... 60 Hz |
| Relative negative tolerance of the control supply voltage frequency | -10 % |
| Relative positive tolerance of the control supply voltage frequency | 10 % |
| Control supply current in standby mode rated value | 100 mA |
| Holding current in the by-pass mode operating rated value | 180 mA |
| Starting current at close of by-pass contact maximum | 0.8 A |
| Inrush current peak at connect of control supply voltage maximum | 43 A |
| Duration of inrush current peak at connect of control supply voltage | 1.6 ms |
| Design of the overvoltage protection | Varistor |
| Design of short-circuit protection for control circuit | 4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply |
| Inputs/ Outputs |
| Number of digital inputs | 4 |
| parameterizable | 4 |
| Number of inputs for thermistor connection | 1; Type A PTC or Klixon / Thermoclick |
| Number of digital outputs | 4 |
| parameterizable | 3 |
| not parameterizable | 1 |
| Digital output version | 3 normally-open contacts (NO) / 1 changeover contact (CO) |
| Number of analog outputs | 1 |
| Switching capacity current of the relay outputs | |
| at AC-15 at 250 V rated value | 3 A |
| at DC-13 at 24 V rated value | 1 A |
| Installation/ mounting/ dimensions |
| Mounting position | Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°) |
| (mounting type) | screw fixing |
| Height | 306 mm |
| Width | 185 mm |
| Depth | 203 mm |
| Required spacing with side-by-side mounting | |
| forwards | 10 mm |
| Backwards | 0 mm |
| upwards | 100 mm |
| downwards | 75 mm |
| at the side | 5 mm |
| Installation altitude at height above sea level maximum | 2 000 m; Derating as of 1000 m, see catalog |
| Weight without packaging | 7.15 kg |
| Connections/Terminals |
| Type of electrical connection | |
| for main current circuit | box terminal |
| for control circuit | screw-type terminals |
| Type of connectable conductor cross-sections | |
| for main contacts for box terminal using the front clamping point solid | 1x (2.5 ... 16 mm²) |
| for main contacts for box terminal using the front clamping point finely stranded with core end processing | 1x (2.5 ... 50 mm²) |
| for main contacts for box terminal using the front clamping point stranded | 1x (10 ... 70 mm²) |
| at AWG conductors for main contacts for box terminal using the front clamping point | 1x (10 ... 2/0) |
| for main contacts for box terminal using the back clamping point solid | 1x (2.5 ... 16 mm²) |
| at AWG conductors for main contacts for box terminal using the back clamping point | 1x (10 ... 2/0) |
| for main contacts for box terminal using both clamping points solid | 2x (2.5 ... 16 mm²) |
| for main contacts for box terminal using both clamping points finely stranded with core end processing | 2x (2.5 ... 35 mm²) |
| for main contacts for box terminal using both clamping points stranded | 2x (6 ... 16 mm²), 2x (10 ... 50 mm²) |
| for main contacts for box terminal using the back clamping point finely stranded with core end processing | 1x (2.5 ... 50 mm²) |
| for main contacts for box terminal using the back clamping point stranded | 1x (10 ... 70 mm²) |
| Type of connectable conductor cross-sections | |
| for control circuit solid | 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) |
| for control circuit finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| at AWG conductors for control circuit solid | 1x (20 ... 12), 2x (20 ... 14) |
| Wire length | |
| between soft starter and motor maximum | 800 m |
| at the digital inputs at DC maximum | 1 000 m |
| Ambient conditions |
| Ambient temperature | |
| during operation | -25 ... +60 °C; Please observe derating at temperatures of 40 °C or above |
| during storage and transport | -25 ... +80 °C |
| Environmental category | |
| during operation acc. to IEC 60721 | 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| during storage acc. to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
| during transport acc. to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
| Communication/ Protocol |
| Communication module is supported | |
| PROFINET standard | Yes |
| Modbus TCP | Yes |
| PROFIBUS | Yes |
| UL/CSA ratings |
| Manufacturer's article number | |
| of fuse | |
| — at Standard Faults usable up to 575/600 V according to UL | Type: Class RK5 / K5, max. 300 A; Iq = 10 kA |
| — at Standard Faults usable at inside-delta circuit up to 575/600 V according to UL | Type: Class RK5 / K5, max. 300 A; Iq = 10 kA |
| Operating power [hp] for three-phase motors | |
| at 200/208 V at 50 °C rated value | 25 hp |
| at 220/230 V at 50 °C rated value | 30 hp |
| at 460/480 V at 50 °C rated value | 60 hp |
| at 575/600 V at 50 °C rated value | 75 hp |
| at 200/208 V at inside-delta circuit at 50 °C rated value | 40 hp |
| at 220/230 V at inside-delta circuit at 50 °C rated value | 50 hp |
| at 460/480 V at inside-delta circuit at 50 °C rated value | 100 hp |
| at 575/600 V at inside-delta circuit at 50 °C rated value | 125 hp |
| Contact rating of auxiliary contacts according to UL | R300-B300 |