| SIRIUS soft starter 200-480 V 32 A, 24 V AC/DC Screw terminals |
Product brand name | SIRIUS |
Product category | Hybrid switching devices |
Product designation | Soft starter |
Manufacturer's article number | |
of HMI-Modul high-feature usable | |
of communication module PROFINET standard usable | |
of communication module PROFIBUS usable | |
of communication module Modbus TCP usable | |
of circuit breaker usable at 400 V | |
of circuit breaker usable at 500 V | |
of circuit breaker usable at 400 V at inside-delta circuit | |
of circuit breaker usable at 500 V at inside-delta circuit | |
of the gG fuse usable up to 690 V | |
of the gG fuse usable at inside-delta circuit up to 500 V | |
of full range R fuse link for semiconductor protection usable up to 690 V | |
of back-up R fuse link for semiconductor protection usable up to 690 V | |
General technical data |
Starting voltage [%] | 20 ... 100 % |
Start-up ramp time of soft starter | 0 ... 360 s |
Stopping time of soft starter | 0 ... 360 s |
Start torque [%] | 10 ... 100 % |
Stopping torque [%] | 10 ... 100 % |
Torque limit [%] | 20 ... 200 % |
Current limiting value [%] adjustable | 125 ... 800 % |
Breakaway voltage [%] adjustable | 40 ... 100 % |
Breakaway time adjustable | 0 ... 2 s |
Number of parameter sets | 3 |
Accuracy class acc. to IEC 61557-12 | 5 % |
Product component | |
HMI-High Feature | Yes |
is supported HMI-High Feature | Yes |
Product feature integrated bypass contact system | Yes |
Number of controlled phases | 3 |
Trip class | CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2 |
Current unbalance limiting value [%] | 10 ... 60 % |
Ground-fault monitoring limiting value [%] | 10 ... 95 % |
Recovery time after overload trip adjustable | 60 ... 1 800 s |
Insulation voltage | |
rated value | 480 V |
Impulse voltage rated value | 6 kV |
Blocking voltage of the thyristor maximum | 1 600 V |
Service factor | 1.15 |
Surge voltage resistance rated value | 6 kV |
maximum permissible voltage for safe isolation | |
between main and auxiliary circuit | 480 V |
Protection class IP | IP00 |
Reference code acc. to DIN EN 81346-2 | Q |
Product function | |
ramp-up (soft starting) | Yes |
ramp-down (soft stop) | Yes |
breakaway pulse | Yes |
Adjustable current limitation | Yes |
creep speed in both directions of rotation | Yes |
pump ramp down | Yes |
DC braking | Yes |
motor heating | Yes |
slave pointer function | Yes |
trace function | Yes |
Intrinsic device protection | Yes |
motor overload protection | Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit. |
Evaluation of thermistor motor protection | Yes; Type A PTC or Klixon / Thermoclick |
inside-delta circuit | Yes |
Auto-reset | Yes |
Manual RESET | Yes |
remote reset | Yes |
communication function | Yes |
operating measured value display | Yes |
event list | Yes |
error logbook | Yes |
via software parameterizable | Yes |
via software configurable | Yes |
PROFIenergy | Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules |
firmware update | Yes |
removable terminal for control circuit | Yes |
combined braking | Yes |
analog output | Yes; 4 ... 20 mA (default) / 0 ... 10 V |
programmable control input-/outputs | Yes |
condition monitoring | Yes |
automatic parameterisation | Yes |
application wizards | Yes |
alternative run-down | Yes |
emergency operation mode | Yes |
reversing operation | Yes |
soft starting at heavy starting conditions | Yes |
Power Electronics |
Operating current | |
at 40 °C rated value | 32 A |
at 50 °C rated value | 28.4 A |
at 60 °C rated value | 26 A |
Operating current at inside-delta circuit | |
at 40 °C rated value | 55.4 A |
at 50 °C rated value | 49 A |
at 60 °C rated value | 45 A |
Operating voltage | |
rated value | 200 ... 480 V |
at inside-delta circuit rated value | 200 ... 480 V |
Relative negative tolerance of the operating voltage | -15 % |
Relative positive tolerance of the operating voltage | 10 % |
Relative negative tolerance of the operating voltage at inside-delta circuit | -15 % |
Relative positive tolerance of the operating voltage at inside-delta circuit | 10 % |
Operating power for three-phase motors | |
at 230 V at 40 °C rated value | 7.5 kW |
at 230 V at inside-delta circuit at 40 °C rated value | 15 kW |
at 400 V at 40 °C rated value | 15 kW |
at 400 V at inside-delta circuit at 40 °C rated value | 22 kW |
Operating frequency 1 rated value | 50 Hz |
Operating frequency 2 rated value | 60 Hz |
Relative negative tolerance of the operating frequency | -10 % |
Relative positive tolerance of the operating frequency | 10 % |
Adjustable motor current | |
minimum | 6.5 A |
at inside-delta circuit minimum | 11.3 A |
Minimum load [%] | 10 %; Relative to set Ie |
Power loss [W] for rated value of the current at AC | |
at 40 °C to power-up | 10 W |
at 50 °C to power-up | 9 W |
at 60 °C to power-up | 8 W |
Control circuit/ Control |
Type of voltage of the control supply voltage | AC/DC |
Control supply voltage at AC | |
at 50 Hz rated value | 24 V |
at 60 Hz rated value | 24 V |
Relative negative tolerance of the control supply voltage at AC at 50 Hz | -20 % |
Relative positive tolerance of the control supply voltage at AC at 50 Hz | 20 % |
Relative negative tolerance of the control supply voltage at AC at 60 Hz | -20 % |
Relative positive tolerance of the control supply voltage at AC at 60 Hz | 20 % |
Control supply voltage frequency | 50 ... 60 Hz |
Relative negative tolerance of the control supply voltage frequency | -10 % |
Relative positive tolerance of the control supply voltage frequency | 10 % |
Control supply voltage | |
at DC rated value | 24 V |
Relative negative tolerance of the control supply voltage at DC | -20 % |
Relative positive tolerance of the control supply voltage at DC | 20 % |
Control supply current in standby mode rated value | 420 mA |
Holding current in the by-pass mode operating rated value | 820 mA |
Starting current at close of by-pass contact maximum | 0.91 A |
Inrush current peak at connect of control supply voltage maximum | 7.5 A |
Duration of inrush current peak at connect of control supply voltage | 20 ms |
Design of the overvoltage protection | Varistor |
Design of short-circuit protection for control circuit | 4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply |
Inputs/ Outputs |
Number of digital inputs | 4 |
parameterizable | 4 |
Number of inputs for thermistor connection | 1; Type A PTC or Klixon / Thermoclick |
Number of digital outputs | 4 |
parameterizable | 3 |
not parameterizable | 1 |
Digital output version | 3 normally-open contacts (NO) / 1 changeover contact (CO) |
Number of analog outputs | 1 |
Switching capacity current of the relay outputs | |
at AC-15 at 250 V rated value | 3 A |
at DC-13 at 24 V rated value | 1 A |
Installation/ mounting/ dimensions |
Mounting position | Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°) |
(mounting type) | screw fixing |
Height | 275 mm |
Width | 170 mm |
Depth | 152 mm |
Required spacing with side-by-side mounting | |
forwards | 10 mm |
Backwards | 0 mm |
upwards | 100 mm |
downwards | 75 mm |
at the side | 5 mm |
Installation altitude at height above sea level maximum | 5 000 m; Derating as of 1000 m, see catalog |
Weight without packaging | 2.6 kg |
Connections/Terminals |
Type of electrical connection | |
for main current circuit | screw-type terminals |
for control circuit | screw-type terminals |
Type of connectable conductor cross-sections | |
for main contacts | |
— solid | 2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²) |
— finely stranded with core end processing | 2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²) |
Type of connectable conductor cross-sections | |
for control circuit solid | 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) |
for control circuit finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
at AWG conductors for control circuit solid | 1x (20 ... 12), 2x (20 ... 14) |
Wire length | |
between soft starter and motor maximum | 800 m |
at the digital inputs at DC maximum | 1 000 m |
Ambient conditions |
Ambient temperature | |
during operation | -25 ... +60 °C; Please observe derating at temperatures of 40 °C or above |
during storage and transport | -25 ... +80 °C |
Environmental category | |
during operation acc. to IEC 60721 | 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
during storage acc. to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
during transport acc. to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
Communication/ Protocol |
Communication module is supported | |
PROFINET standard | Yes |
Modbus TCP | Yes |
PROFIBUS | Yes |
UL/CSA ratings |
Manufacturer's article number | |
of fuse | |
— at Standard Faults usable up to 575/600 V according to UL | Type: Class RK5 / K5, max. 125 A; Iq = 5 kA |
— at Standard Faults usable at inside-delta circuit up to 575/600 V according to UL | Type: Class RK5 / K5, max. 125 A; Iq = 5 kA |
Operating power [hp] for three-phase motors | |
at 200/208 V at 50 °C rated value | 7.5 hp |
at 220/230 V at 50 °C rated value | 10 hp |
at 460/480 V at 50 °C rated value | 20 hp |
at 200/208 V at inside-delta circuit at 50 °C rated value | 15 hp |
at 220/230 V at inside-delta circuit at 50 °C rated value | 15 hp |
at 460/480 V at inside-delta circuit at 50 °C rated value | 30 hp |
Contact rating of auxiliary contacts according to UL | R300-B300 |