3RW5235-6AC04
3RW52 480V 143A 24V screw analog

From SIEMENS

SIRIUS soft starter 200-480 V 143 A, 24 V AC/DC Screw terminals Analog output
Product brand nameSIRIUS
Product categoryHybrid switching devices
Product designationSoft starter
Manufacturer's article number
of HMI module usable
of HMI-Modul high-feature usable
of communication module PROFINET standard usable
of communication module PROFIBUS usable
of communication module Modbus TCP usable
of circuit breaker usable at 400 V
of circuit breaker usable at 400 V at inside-delta circuit
of the gG fuse usable up to 690 V
of the gG fuse usable at inside-delta circuit up to 500 V
of full range R fuse link for semiconductor protection usable up to 690 V
of back-up R fuse link for semiconductor protection usable up to 690 V
General technical data
Starting voltage [%]30 ... 100 %
Start-up ramp time of soft starter0 ... 20 s
Current limiting value [%] adjustable130 ... 700 %
Product component
is supported HMI-StandardYes
is supported HMI-High FeatureYes
Product feature integrated bypass contact systemYes
Number of controlled phases3
Trip classCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Insulation voltage
rated value600 V
Impulse voltage rated value6 kV
Blocking voltage of the thyristor maximum1 400 V
Service factor1
Surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation
between main and auxiliary circuit600 V
Protection class IPIP00
Usage category acc. to IEC 60947-4-2AC 53a
Shock resistance15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
Reference code acc. to DIN EN 81346-2Q
Product function
ramp-up (soft starting)Yes
ramp-down (soft stop)Yes
Soft TorqueYes
Adjustable current limitationYes
pump ramp downYes
Intrinsic device protectionYes
motor overload protectionYes; Electronic motor overload protection
Evaluation of thermistor motor protectionNo
inside-delta circuitYes
Auto-resetYes
Manual RESETYes
remote resetYes; By turning off the control supply voltage
communication functionYes
via software configurableYes
PROFIenergyYes; in connection with the PROFINET Standard communication module
firmware updateYes
removable terminal for control circuitYes
analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Power Electronics
Operating current
at 40 °C rated value143 A
at 50 °C rated value128 A
at 60 °C rated value118 A
Operating current at inside-delta circuit
at 40 °C rated value248 A
at 50 °C rated value222 A
at 60 °C rated value204 A
Operating voltage
rated value200 ... 480 V
at inside-delta circuit rated value200 ... 480 V
Relative negative tolerance of the operating voltage-15 %
Relative positive tolerance of the operating voltage10 %
Relative negative tolerance of the operating voltage at inside-delta circuit-15 %
Relative positive tolerance of the operating voltage at inside-delta circuit10 %
Operating power for three-phase motors
at 230 V at 40 °C rated value37 kW
at 230 V at inside-delta circuit at 40 °C rated value75 kW
at 400 V at 40 °C rated value75 kW
at 400 V at inside-delta circuit at 40 °C rated value132 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
Relative negative tolerance of the operating frequency-10 %
Relative positive tolerance of the operating frequency10 %
Adjustable motor current
minimum68 A
at inside-delta circuit minimum118 A
Minimum load [%]15 %; Relative to smallest settable Ie
Power loss [W] for rated value of the current at AC
at 40 °C to power-up55 W
at 50 °C to power-up50 W
at 60 °C to power-up47 W
Control circuit/ Control
Type of voltage of the control supply voltageAC/DC
Control supply voltage at AC
at 50 Hz rated value24 V
at 60 Hz rated value24 V
Relative negative tolerance of the control supply voltage at AC at 50 Hz-20 %
Relative positive tolerance of the control supply voltage at AC at 50 Hz20 %
Relative negative tolerance of the control supply voltage at AC at 60 Hz-20 %
Relative positive tolerance of the control supply voltage at AC at 60 Hz20 %
Control supply voltage frequency50 ... 60 Hz
Relative negative tolerance of the control supply voltage frequency-10 %
Relative positive tolerance of the control supply voltage frequency10 %
Control supply voltage
at DC rated value24 V
Relative negative tolerance of the control supply voltage at DC-20 %
Relative positive tolerance of the control supply voltage at DC20 %
Control supply current in standby mode rated value160 mA
Holding current in the by-pass mode operating rated value380 mA
Starting current at close of by-pass contact maximum7.6 A
Inrush current peak at connect of control supply voltage maximum3.3 A
Duration of inrush current peak at connect of control supply voltage12.1 ms
Design of the overvoltage protectionVaristor
Design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
Inputs/ Outputs
Number of digital inputs1
Number of inputs for thermistor connection0
Number of digital outputs3
not parameterizable2
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)
Number of analog outputs1
Switching capacity current of the relay outputs
at AC-15 at 250 V rated value3 A
at DC-13 at 24 V rated value1 A
Installation/ mounting/ dimensions
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
(mounting type)screw fixing
Height306 mm
Width185 mm
Depth203 mm
Required spacing with side-by-side mounting
forwards10 mm
Backwards0 mm
upwards100 mm
downwards75 mm
at the side5 mm
Installation altitude at height above sea level maximum5 000 m; Derating as of 1000 m, see catalog
Weight without packaging6.6 kg
Connections/Terminals
Type of electrical connection
for main current circuitscrew-type terminals
for control circuitscrew-type terminals
Type of connectable conductor cross-sections
for DIN cable lug for main contacts stranded2x (16 ... 95 mm²)
for DIN cable lug for main contacts finely stranded2x (25 ... 120 mm²)
Type of connectable conductor cross-sections
for control circuit solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
for control circuit finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
at AWG conductors for control circuit solid1x (20 ... 12), 2x (20 ... 14)
Wire length
between soft starter and motor maximum800 m
at the digital inputs at AC maximum100 m
at the digital inputs at DC maximum1 000 m
Ambient conditions
Ambient temperature
during operation-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
during storage and transport-40 ... +80 °C
Environmental category
during operation acc. to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage acc. to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
during transport acc. to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
Communication/ Protocol
Communication module is supported
PROFINET standardYes
Modbus TCPYes
PROFIBUSYes
UL/CSA ratings
Manufacturer's article number
of fuse
— at Standard Faults usable up to 575/600 V according to ULType: Class RK5 / K5, max. 350 A; Iq = 10 kA
— at Standard Faults usable at inside-delta circuit up to 575/600 V according to ULType: Class RK5 / K5, max. 350 A; Iq = 10 kA
Operating power [hp] for three-phase motors
at 200/208 V at 50 °C rated value40 hp
at 220/230 V at 50 °C rated value40 hp
at 460/480 V at 50 °C rated value100 hp
at 200/208 V at inside-delta circuit at 50 °C rated value75 hp
at 220/230 V at inside-delta circuit at 50 °C rated value75 hp
at 460/480 V at inside-delta circuit at 50 °C rated value150 hp
Contact rating of auxiliary contacts according to ULR300-B300