| Overload relay 2.2...3.2 A For motor protection Size S00, Class 10 Contactor mounting Main circuit: Screw terminal Auxiliary circuit: Screw terminal Manual-Automatic-Reset !!! Phased-out product !!! Successor is SIRIUS 3RU2 |
Product brand name | SIRIUS |
Product designation | thermal overload relay |
General technical data |
Size of overload relay | S00 |
Size of contactor can be combined company-specific | S00 |
Power loss [W] total typical | 6.6 W |
Insulation voltage with degree of pollution 3 rated value | 690 V |
Surge voltage resistance rated value | 6 kV |
Protection class IP | |
on the front | IP20 |
Shock resistance | 8g / 10 ms |
Type of protection | DMT 98 ATEX G 001 |
Protection against electrical shock | finger-safe |
Reference code acc. to DIN EN 81346-2 | F |
Ambient conditions |
Installation altitude at height above sea level | |
maximum | 2 000 m |
Relative humidity during operation | 100 % |
Main circuit |
Number of poles for main current circuit | 3 |
Adjustable pick-up value current of the current-dependent overload release | 2.2 ... 3.2 A |
Operating voltage | |
at AC-3 rated value maximum | 690 V |
Auxiliary circuit |
Number of NC contacts for auxiliary contacts | 1 |
Number of NO contacts for auxiliary contacts | 1 |
Number of CO contacts | |
for auxiliary contacts | 0 |
Operating current of auxiliary contacts at AC-15 | |
at 24 V | 3 A |
at 110 V | 3 A |
at 120 V | 3 A |
at 125 V | 3 A |
at 230 V | 2 A |
at 400 V | 1 A |
Operating current of auxiliary contacts at DC-13 | |
at 24 V | 1 A |
at 110 V | 0.22 A |
at 125 V | 0.22 A |
at 220 V | 0.11 A |
Protective and monitoring functions |
Trip class | CLASS 10 |
Short-circuit protection |
Design of the fuse link | |
for short-circuit protection of the auxiliary switch required | fuse gL/gG: 6 A, quick: 10 A |
Installation/ mounting/ dimensions |
Mounting position | with vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back |
Mounting type | Mounting contactor |
Height | 87 mm |
Width | 45 mm |
Depth | 78 mm |
Required spacing | |
with side-by-side mounting | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
for grounded parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— at the side | 6 mm |
— downwards | 0 mm |
for live parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 6 mm |
Connections/Terminals |
Product function | |
removable terminal for auxiliary and control circuit | No |
Type of electrical connection | |
for main current circuit | screw-type terminals |
for auxiliary and control current circuit | screw-type terminals |
Type of connectable conductor cross-sections | |
for main contacts | |
— solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² max. |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
at AWG conductors for main contacts | 2x (20 ... 16), 2x (18 ... 14), 2x 12 |
Type of connectable conductor cross-sections | |
for auxiliary contacts | |
— solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
at AWG conductors for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14) |