3RQ3118-2AM01
PLUG-IN RELAY 24V DC,1CO,HTV, SPRING

From SIEMENS

Output coupler with plug-in Relay, 1 CO, hard gold-plated Spring-type terminal (push-in) 24 V DC Enclosure width 6.2 mm Thermal current 6A
Product brand nameSIRIUS
Product categorySIRIUS 3RQ3 coupling relays in slim design
Product designationCoupling relays with plug-in relay
Design of the productOutput coupling link
Product type designation3RQ3
General technical data
Display version LEDYes
Product component
Relay outputYes
semi-conductor outputNo
Consumed active power0.3 W
Insulation voltage
for overvoltage category III according to IEC 60664
— with degree of pollution 3 rated value300 V
Surge voltage resistance rated value4 kV
maximum permissible voltage for safe isolation
between control and auxiliary circuit300 V
Percental drop-out voltage related to the input voltage10 %
Protection class IPIP20
Shock resistance
acc. to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
Operating frequency maximum72 000 1/h
Switching behaviormonostable
Mechanical service life (switching cycles)
typical10 000 000
Electrical endurance (switching cycles)
at AC-15 at 230 V typical100 000
Thermal current6 A
Reference code acc. to DIN EN 81346-2K
Reference code acc. to DIN EN 61346-2K
Control circuit/ Control
Control supply voltage at DC
rated value24 V
Operating range factor control supply voltage rated value at DC
initial value0.8
Full-scale value1.25
Switch-on delay time
at DC maximum12 ms
Off-delay time13 ms
Closing delay
at DC6 ms
Opening delay
at DC13 ms
Design of the relay operating mechanismpoled
Product component Plug-in socketYes
Short-circuit protection
Design of the fuse link
for short-circuit protection of the auxiliary switch requiredfuse gG: 4 A
Auxiliary circuit
Type of switching contactChangeover contact
Material of switching contactsAgSnO2-HTV
Number of CO contacts
for auxiliary contacts1
Operating current of auxiliary contacts at AC-15
at 24 V3 A
at 250 V3 A
Operating current of auxiliary contacts at DC-13
at 24 V1 A
at 125 V0.2 A
at 250 V0.1 A
Contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (5 V, 1 mA)
Main circuit
Type of voltageDC
Inputs/ Outputs
Property of the output Short-circuit proofNo
Outputs
Ampacity of the output relay at AC-15
at 250 V at 50/60 Hz3 A
Ampacity of the output relay at DC-13
at 24 V1 A
at 125 V0.2 A
at 250 V0.1 A
Electromagnetic compatibility
EMC emitted interference
acc. to IEC 60947-1ambience A (industrial sector)
EMI immunity
acc. to IEC 60947-1corresponds to degree of severity 3
Conducted interference
due to burst acc. to IEC 61000-4-42 kV
due to conductor-earth surge acc. to IEC 61000-4-52 kV
due to conductor-conductor surge acc. to IEC 61000-4-51 kV
Field-bound parasitic coupling acc. to IEC 61000-4-310 V/m
Electrostatic discharge acc. to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
Display
Display version
as status display by LEDLED green
Connections/Terminals
Product function
removable terminalNo
Type of electrical connection
for auxiliary and control current circuitPUSH-IN connection (spring-loaded connection)
Wire length
at DC maximum1 000 m
Type of connectable conductor cross-sections
solid1x (0.25 ... 2.5 mm²)
finely stranded with core end processing1x (0.25 ... 1.5 mm²)
finely stranded without core end processing1x (0.25 ... 2.5 mm²)
at AWG conductors solid1 x (20 ... 14)
at AWG conductors stranded1x (20 ... 14)
Connectable conductor cross-section
solid0.25 ... 2.5 mm²
finely stranded with core end processing0.25 ... 1.5 mm²
finely stranded without core end processing0.25 ... 2.5 mm²
AWG number as coded connectable conductor cross section
solid20 ... 14
stranded20 ... 14
Installation/ mounting/ dimensions
Mounting positionany
Mounting typesnap-on mounting
Height93 mm
Width6.2 mm
Depth76 mm
Required spacing
with side-by-side mounting
— forwards0 mm
— Backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
for grounded parts
— forwards0 mm
— Backwards0 mm
— upwards0 mm
— at the side0 mm
— downwards0 mm
for live parts
— forwards0 mm
— Backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
Ambient conditions
Installation altitude at height above sea level
maximum2 000 m
Ambient temperature
during operation-25 ... +60 °C
during storage-40 ... +85 °C
during transport-40 ... +85 °C
Relative humidity
during operation10 ... 95 %