3RQ2000-1CW00
COUPLING RELAY IM

From SIEMENS

Coupling relays in industrial enclosure 3 change-over contacts Wide voltage range 24 V to 240 V AC/DC screw terminal
Product brand nameSIRIUS
Product designationCoupling relay in industrial enclosure
Product type designation3RQ2
General technical data
Consumed active power5 W
Insulation voltage
for overvoltage category III according to IEC 60664
— with degree of pollution 3 rated value300 V
Degree of pollution3
Surge voltage resistance rated value4 kV
maximum permissible voltage for safe isolation
between auxiliary and auxiliary circuit300 V
between control and auxiliary circuit acc. to IEC 60947-1300 V
Protection class IPIP20
Shock resistance
acc. to IEC 60068-2-2711g / 15 ms
for railway applications acc. to DIN EN 61373Category 1, Class B
Switching behaviormonostable
Mechanical service life (switching cycles)
typical10 000 000
Electrical endurance (switching cycles)
at AC-15 at 230 V typical100 000
Thermal current of the switching element with contacts maximum5 A
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750K
Reference code acc. to DIN EN 81346-2K
Reference code acc. to DIN EN 61346-2K
Control circuit/ Control
Control supply voltage 1 at AC
at 50 Hz24 ... 240 V
at 60 Hz24 ... 240 V
Control supply voltage 1
at DC24 ... 240 V
Operating range factor control supply voltage rated value at DC
initial value0.7
Full-scale value1.1
Operating range factor control supply voltage rated value at AC at 50 Hz
initial value0.7
Full-scale value1.1
Operating range factor control supply voltage rated value at AC at 60 Hz
initial value0.7
Full-scale value1.1
Switch-on delay time
at AC maximum10 ms
at DC maximum10 ms
Off-delay time100 ms
Design of the relay operating mechanismpoled
Product component Plug-in socketNo
Short-circuit protection
Design of the fuse link
for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 6 A
Auxiliary circuit
Material of switching contactsAgSnO2
Number of NC contacts for auxiliary contacts0
Number of NO contacts for auxiliary contacts0
Number of CO contacts
for auxiliary contacts3
Contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
Type of voltageAC/DC
Outputs
Ampacity of the output relay at AC-15
at 24 V at 50/60 Hz3 A
at 110 V at 50/60 Hz3 A
at 250 V at 50/60 Hz3 A
Ampacity of the output relay at DC-13
at 24 V1 A
at 125 V0.2 A
at 250 V0.1 A
Electromagnetic compatibility
EMC emitted interference
acc. to IEC 60947-1ambience A (industrial sector)
EMI immunity
acc. to IEC 60947-1corresponds to degree of severity 3
Conducted interference
due to burst acc. to IEC 61000-4-42 kV
due to conductor-earth surge acc. to IEC 61000-4-52 kV (line to ground)
due to conductor-conductor surge acc. to IEC 61000-4-51 kV (line to line)
Field-bound parasitic coupling acc. to IEC 61000-4-310 V/m
Electrostatic discharge acc. to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Safety related data
Electromagnetic compatibilityIEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4
Connections/Terminals
Product function
removable terminal for auxiliary and control circuitYes
Type of electrical connectionscrew-type terminals
Type of connectable conductor cross-sections
solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
finely stranded with core end processing1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²)
at AWG conductors solid1x (20 ... 12), 2x (20 ... 14)
Connectable conductor cross-section
solid0.5 ... 4 mm²
finely stranded with core end processing4 mm²
finely stranded without core end processing0.5 mm²
AWG number as coded connectable conductor cross section
solid12 ... 20
stranded12 ... 20
Tightening torque
with screw-type terminals0.6 ... 0.8 N·m
Wire stripping length of the cable
for auxiliary and control contacts10 mm
Installation/ mounting/ dimensions
Mounting positionany
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail
Height100 mm
Width22.5 mm
Depth90 mm
Ambient conditions
Installation altitude at height above sea level
maximum2 000 m
Ambient temperature
during operation-40 ... +60 °C
during storage-40 ... +80 °C
during transport-40 ... +80 °C
Relative humidity
during operation10 ... 95 %

External links