| SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Basic Mechanical switching AC-3, 5.5 kW / 400 V 1.5 A...12.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 2DI AS-i + 2DI / 1DO on device Han Q4/2 - Han Q8/0 |
| Product brand name | SIRIUS |
| Product designation | Motor starters |
| Design of the product | direct starter |
| Product type designation | M200D |
| Product function | |
| on-site operation | No |
| Control circuit interface to parallel wiring | No |
| Power loss [W] typical | 30 W |
| Insulation voltage rated value | 500 V |
| Degree of pollution | 3 |
| Surge voltage resistance rated value | 6 000 V |
| maximum permissible voltage for safe isolation | |
| between main and auxiliary circuit | 400 V |
| between control and auxiliary circuit | 24 V |
| Protection class IP | IP65 |
| Shock resistance | 12g / 11 ms |
| Mechanical service life (switching cycles) of the main contacts typical | 10 000 000 |
| Type of assignment | 1 |
| Certificate of suitability | CE |
| Reference code acc. to DIN EN 61346-2 | Q |
| Product function | |
| direct start | Yes |
| reverse starting | No |
| Product component Motor brake output | No |
| Product feature | |
| brake control with 230 V AC | No |
| brake control with 400 V AC | No |
| brake control with 24 V DC | No |
| brake control with 180 V DC | No |
| brake control with 500 V DC | No |
| Product extension braking module for brake control | No |
| Product function Short circuit protection | Yes |
| Design of short-circuit protection | circuit-breakers |
| Trip class | CLASS 10 |
| Maximum short-circuit current breaking capacity (Icu) | |
| at 400 V rated value | 50 000 A |
| at 500 V rated value | 50 000 A |
| EMC emitted interference acc. to IEC 60947-1 | CISPR11, ambience A (industrial sector) |
| EMI immunity acc. to IEC 60947-1 | corresponds to degree of severity 3, ambience A (industrial sector) |
| Conducted interference | |
| due to burst acc. to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
| due to conductor-earth surge acc. to IEC 61000-4-5 | 2 kV |
| due to conductor-conductor surge acc. to IEC 61000-4-5 | 1 kV |
| Protection against electrical shock | finger-safe |
| Main circuit |
| Number of poles for main current circuit | 3 |
| Design of the switching contact | electromechanical |
| Adjustable pick-up value current of the current-dependent overload release | 1.5 ... 12 A |
| Type of the motor protection | full motor protection |
| Operating voltage rated value | 360 ... 440 V |
| Operating current | |
| at AC at 400 V rated value | 12 A |
| at AC-3 at 400 V rated value | 12 A |
| Operating power at AC-3 | |
| at 400 V rated value | 5.5 kW |
| at 500 V rated value | 5 500 W |
| Product function | |
| digital inputs parameterizable | No |
| digital outputs parameterizable | No |
| Number of digital inputs | 4 |
| Number of sockets | |
| for digital output signals | 1 |
| for digital input signals | 4 |
| Number of digital outputs | 1 |
| Supply voltage |
| Type of voltage of the supply voltage | DC |
| Supply voltage 1 at DC rated value | 30 V |
| minimum permissible | 26.5 V |
| maximum permissible | 31.6 V |
| Control circuit/ Control |
| Type of voltage of the control supply voltage | DC |
| Control supply voltage at DC | |
| rated value | 20.4 ... 28.8 V |
| Control supply voltage 1 | |
| at DC rated value | 24 V |
| at DC rated value | 20.4 ... 28.8 V |
| at DC | 20.4 ... 28.8 V |
| Power loss [W] in auxiliary and control circuit | |
| in switching state OFF with bypass circuit | 2.0736 W |
| in switching state ON with bypass circuit | 4.1184 W |
| Response times |
| Switch-on delay time | 85 ms |
| Off-delay time | 65 ms |
| Mounting position | vertical, horizontal, flat |
| recommended | horizontal |
| Mounting type | screw fixing |
| Height | 215 mm |
| Width | 294 mm |
| Depth | 159 mm |
| Installation altitude at height above sea level maximum | 2 000 m |
| Ambient temperature | |
| during operation | -25 ... +55 °C |
| during storage | -40 ... +70 °C |
| during transport | -40 ... +70 °C |
| Relative humidity during operation | 10 ... 95 % |
| Protocol is supported | |
| PROFIBUS DP protocol | No |
| PROFINET protocol | No |
| Design of the interface | |
| AS-interface protocol | Yes |
| PROFINET protocol | No |
| PROFIBUS DP protocol | No |
| Product function Bus communication | Yes |
| Protocol is supported AS-interface protocol | Yes |
| Product function Control circuit interface with IO link | No |
| Type of electrical connection of the communication interface | M12 plug |
| Type of electrical connection | |
| for main current circuit | plug according to ISO 23570, HAN Q4/2 |
| for auxiliary and control current circuit | connector |
| Type of electrical connection | |
| 1 for digital input signals | M12 socket |
| 1 for digital output signals | M12 socket |
| 2 for digital input signals | M12 socket |
| 3 for digital input signals | M12 socket |
| 4 for digital input signals | M12 socket |
| Type of electrical connection | |
| at the manufacturer-specific device interface | optical interface |
| for device addressing | M12 plug |
| for supply voltage line-side | M12 plug |