3LD2524-7UL01-0AD8
3LD switch disconnector, Selector switch

From SIEMENS

SENTRON, Switch disconnector 3LD, change-over switch, 4-pole, Iu: 63 A, Operating power / at AC-23 A at 400 V: 22 kW, front-mounted, knob-operated mechanism, black, 4-hole mounting of the handle
Model
Product brand nameSENTRON
Product designation3LD Switch disconnector
Design of the productSelector switch
Display version / for switch position indicator manual operation1 ON - 0 OFF - 2 ON
Design of the operating mechanismselector switch
Design of handleknob-operated mechanism, black
Type of the driving mechanism / motor driveNo
General technical data
Number of poles4
Type of devicefixed mounting
Type of switchfront mounted
Size of switch disconnector3
Electrical endurance (switching cycles) / at AC-23 A / at 690 V6 000
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum21 kA2.s
Let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum21 kA2.s
Mechanical service life (switching cycles) / typical100 000
Operating frequency / maximum50 1/h
Voltage
Insulation voltage / rated value690 V
Surge voltage resistance / rated value6 kV
Current / at AC / rated value63 A
Operating voltage
at AC / at 50/60 Hz / rated value690 V
Protection class
Protection class IPIP65
Protection class IP / on the frontIP65
Dissipation
Power loss [W]
for rated value of the current / at AC / in hot operating state / per pole4.5 W
per conductor / typical4.5 W
Current
Operating current
at AC-23 A / at 690 V / rated value22 A
at AC-23 A / at 400 V / rated value43 A
at AC-22 A / at 690 V / rated value63 A
at AC-21 / at 690 V / rated value63 A
at AC-21 A / at 240 V / rated value63 A
at AC-21 A / at 440 V / rated value63 A
at AC-22 A / at 240 V / rated value63 A
at AC-22 A / at 440 V / rated value63 A
at AC-23 A / at 240 V / rated value43 A
at AC-23 A / at 440 V / rated value43 A
Continuous current
rated value63 A
at 40 °C / rated value63 A
at 45 °C / rated value63 A
at 50 °C / rated value63 A
at 55 °C / rated value63 A
Operating current / of upstream fuse / rated value63 A
Let-through current / with closed switch
at 440 V / for combination switch + gG fuse / maximum6 kA
at 690 V / for combination switch + gG fuse / maximum permissible6 kA
Short-time withstand current (Icw)
limited to 1 s / rated value1 260 A
at 690 V / limited to 1 s / rated value1 260 A
Main circuit
Operating frequency
initial value50 Hz
Full-scale value60 Hz
Operating power
at AC-23 A / at 240 V / rated value11 kW
at AC-23 A / at 400 V / at 50/60 Hz / rated value22 kW
at AC-23 A / at 400 V / rated value22 kW
at AC-23 A / at 440 V / rated value22 kW
at AC-23 A / at 690 V / rated value18.5 kW
at AC-3 / at 240 V / rated value11 kW
at AC-3 / at 400 V / rated value18.5 kW
at AC-3 / at 690 V / rated value15 kW
Operating current / rated value63 A
Auxiliary circuit
Number of CO contacts / for auxiliary contacts0
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Operating voltage / of auxiliary contacts / at AC / maximum500 V
Continuous current / of the auxiliary contact / rated value10 A
Insulation voltage / of the auxiliary switch / rated value500 V
Suitability
Suitability for use
Main switchYes
switch disconnectorYes
EMERGENCY OFF switchNo
safety switchYes
maintenance/repair switchYes
Appearance
Color / of the actuating elementblack
Product details
Product function / can be locked into OFF positionNo
Short circuit
Conditional short-circuit current / with line-side fuse protection
at 690 V / by gG fuse / rated value50 kA
Number of connectable NC contacts / for auxiliary contacts / attachable / maximum0
Number of connectable NO contacts / for auxiliary contacts / attachable / maximum0
Number of connectable CO contacts / for auxiliary contacts / attachable / maximum0
Connections
AWG number / as coded connectable conductor cross section / solid
maximum14
minimum6
Type of electrical connection
for main current circuitbox terminal
for auxiliary contactsconnection terminals
Requirements
Design of the fuse link
for short-circuit protection of the main circuit / requiredfuse gL/gG: 63 A
for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A
Mechanical Design
Height92 mm
Width120 mm
Depth73 mm
Mounting typeBuilt-in unit fixed-mounted version
Mounting type
front mounting with 4-hole attachmentYes
front mounting with central attachmentNo
rail mountingNo
Net weight1 101 g
Environmental conditions
Ambient temperature / during operation
minimum-25 °C
maximum55 °C
Ambient temperature / during storage / minimum-25 °C