| SENTRON, Switch disconnector 3LD, emergency switching-off switch, 4- pole, Iu: 32 A, operating power / at AC-23 A 400 V: 11.5 kW, installation in distribution boards, 1 NC, 1 NO, knob-operated mechanism, Red / yellow, handle direct at the switch |
Model |
Product brand name | SENTRON |
Product designation | 3LD Switch disconnector |
Design of the product | EMERGENCY-STOP switch |
Display version / for switch position indicator manual operation | 1 ON - 0 OFF |
Design of the operating mechanism | selector switch |
Design of handle | knob-operated mechanism, red/yellow |
Type of the driving mechanism / motor drive | No |
General technical data |
Number of poles | 4 |
Type of device | fixed mounting |
Type of switch | DIN-rail mounting |
Size of switch disconnector | 2 |
Electrical endurance (switching cycles) / at AC-23 A / at 690 V | 6 000 |
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum | 9 kA2.s |
Let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum | 9 kA2.s |
Mechanical service life (switching cycles) / typical | 100 000 |
Operating frequency / maximum | 50 1/h |
Voltage |
Insulation voltage / rated value | 690 V |
Surge voltage resistance / rated value | 6 kV |
Current / at AC / rated value | 32 A |
Operating voltage | |
at AC / at 50/60 Hz / rated value | 690 V |
Protection class |
Protection class IP | IP40 |
Protection class IP / on the front | IP40 |
Dissipation |
Power loss [W] | |
for rated value of the current / at AC / in hot operating state / per pole | 1.8 W |
per conductor / typical | 1.8 W |
Current |
Operating current | |
at AC-23 A / at 690 V / rated value | 13 A |
at AC-23 A / at 400 V / rated value | 22 A |
at AC-22 A / at 690 V / rated value | 32 A |
at AC-21 / at 690 V / rated value | 32 A |
at AC-21 A / at 240 V / rated value | 32 A |
at AC-21 A / at 440 V / rated value | 32 A |
at AC-22 A / at 240 V / rated value | 32 A |
at AC-22 A / at 440 V / rated value | 32 A |
at AC-23 A / at 240 V / rated value | 22 A |
at AC-23 A / at 440 V / rated value | 22 A |
Continuous current | |
rated value | 32 A |
at 40 °C / rated value | 32 A |
at 45 °C / rated value | 32 A |
at 50 °C / rated value | 32 A |
at 55 °C / rated value | 32 A |
Operating current / of upstream fuse / rated value | 40 A |
Let-through current / with closed switch | |
at 440 V / for combination switch + gG fuse / maximum | 4.5 kA |
at 690 V / for combination switch + gG fuse / maximum permissible | 4.5 kA |
Short-time withstand current (Icw) | |
limited to 1 s / rated value | 640 A |
at 690 V / limited to 1 s / rated value | 640 A |
Main circuit |
Operating frequency | |
initial value | 50 Hz |
Full-scale value | 60 Hz |
Operating power | |
at AC-23 A / at 240 V / rated value | 6 kW |
at AC-23 A / at 400 V / at 50/60 Hz / rated value | 11.5 kW |
at AC-23 A / at 400 V / rated value | 11.5 kW |
at AC-23 A / at 440 V / rated value | 11.5 kW |
at AC-23 A / at 690 V / rated value | 11.5 kW |
at AC-3 / at 240 V / rated value | 5.5 kW |
at AC-3 / at 400 V / rated value | 9.5 kW |
at AC-3 / at 690 V / rated value | 9.5 kW |
Operating current / rated value | 32 A |
Auxiliary circuit |
Number of CO contacts / for auxiliary contacts | 0 |
Number of NC contacts / for auxiliary contacts | 1 |
Number of NO contacts / for auxiliary contacts | 1 |
Operating voltage / of auxiliary contacts / at AC / maximum | 500 V |
Continuous current / of the auxiliary contact / rated value | 10 A |
Insulation voltage / of the auxiliary switch / rated value | 500 V |
Suitability |
Suitability for use | |
Main switch | Yes |
switch disconnector | Yes |
EMERGENCY OFF switch | Yes |
safety switch | Yes |
maintenance/repair switch | Yes |
Appearance |
Color / of the actuating element | red |
Product details |
Product function / can be locked into OFF position | Yes |
Number of bracket locks / maximum | 2 |
Hasp thickness / of the bracket locks / minimum | 4 mm |
Hasp thickness / of the bracket locks / maximum | 6 mm |
Short circuit |
Conditional short-circuit current / with line-side fuse protection | |
at 690 V / by gG fuse / rated value | 50 kA |
Number of connectable NC contacts / for auxiliary contacts / attachable / maximum | 1 |
Number of connectable NO contacts / for auxiliary contacts / attachable / maximum | 2 |
Number of connectable CO contacts / for auxiliary contacts / attachable / maximum | 0 |
Connections |
AWG number / as coded connectable conductor cross section / solid | |
maximum | 14 |
minimum | 8 |
Type of electrical connection | |
for main current circuit | box terminal |
for auxiliary contacts | connection terminals |
Requirements |
Design of the fuse link | |
for short-circuit protection of the main circuit / required | fuse gL/gG: 40 A |
for short-circuit protection of the auxiliary switch / required | fuse gL/gG: 10 A |
Mechanical Design |
Height | 79 mm |
Width | 72 mm |
Depth | 55 mm |
Mounting type | Built-in unit fixed-mounted version |
Mounting type | |
front mounting with 4-hole attachment | No |
front mounting with central attachment | No |
rail mounting | Yes |
Net weight | 204 g |
Environmental conditions |
Ambient temperature / during operation | |
minimum | -25 °C |
maximum | 55 °C |
Ambient temperature / during storage / minimum | -25 °C |