Product Datasheet Search Results:

ST30Y2.pdf1 Pages, 4 KB, Original

Product Details Search Results:

Abb.com/YST301QP10K3
{"I(T) Max.(A) On-state Current":"500","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.0k","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"20uò"}...
968 Bytes - 15:45:05, 29 November 2024
Abb.com/YST301QP2K3
{"I(T) Max.(A) On-state Current":"500","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"200","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"20uò"}...
962 Bytes - 15:45:05, 29 November 2024
Abb.com/YST301QP4K3
{"I(T) Max.(A) On-state Current":"500","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"400","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"20uò"}...
962 Bytes - 15:45:05, 29 November 2024
Abb.com/YST301QP6K3
{"I(T) Max.(A) On-state Current":"500","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"600","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"20uò"}...
962 Bytes - 15:45:05, 29 November 2024
Abb.com/YST301QP8K3
{"I(T) Max.(A) On-state Current":"500","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"800","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"20uò"}...
961 Bytes - 15:45:05, 29 November 2024
Abb.com/YST302QP10K3
{"I(T) Max.(A) On-state Current":"450","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.0k","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"60uò"}...
968 Bytes - 15:45:05, 29 November 2024
Abb.com/YST302QP12K3
{"I(T) Max.(A) On-state Current":"450","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.2k","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"60uò"}...
968 Bytes - 15:45:05, 29 November 2024
Abb.com/YST302QP14K3
{"I(T) Max.(A) On-state Current":"450","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.4k","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"60uò"}...
967 Bytes - 15:45:05, 29 November 2024
Abb.com/YST302QP2K3
{"I(T) Max.(A) On-state Current":"450","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"200","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"60uò"}...
962 Bytes - 15:45:05, 29 November 2024
Abb.com/YST302QP4K3
{"I(T) Max.(A) On-state Current":"450","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"400","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"60uò"}...
962 Bytes - 15:45:05, 29 November 2024
Abb.com/YST302QP6K3
{"I(T) Max.(A) On-state Current":"450","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"600","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"60uò"}...
962 Bytes - 15:45:05, 29 November 2024
Abb.com/YST302QP8K3
{"I(T) Max.(A) On-state Current":"450","V(T) Max. (V)":"1.9","Status":"Discontinued","@Temp. (°C) (Test Condition)":"125","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"1.0k","Package":"TO-200var85","V(DRM) Max.(V)Rep.Pk.Off Volt.":"800","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"220m","V(GT) Max.(V)":"3.5","Military":"N","I(D) Max. (A) Leakage Current":"30m","I(TSM) Max. (A)":"7.4k","t(q) Typ. (s)":"60uò"}...
962 Bytes - 15:45:05, 29 November 2024

Documentation and Support

Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:

File NameFile Size (MB)DocumentMOQSupport
IXST30N60B2D1.pdf0.061Request
IXST30N60B.pdf0.061Request
IXST30N60B2D1.pdf0.601Request
IXST30N60B.pdf0.131Request
IXST30N60BD1.pdf0.121Request
IXST30N60CD1.pdf0.071Request
IXST30N60C.pdf0.131Request
ST307_V2_150_S_S_SAE_4_UNF_7_16.pdf0.101Request
ST307_150S_S_SAE_4_UNF_7_16.pdf0.101Request
ST307_350_B.pdf0.101Request
ST307_SCH_V2_55_B.pdf0.101Request
ST307_V2_150_B.pdf0.101Request