Product Datasheet Search Results:

1DI300G-120.pdf1 Pages, 97 KB, Original

Product Details Search Results:

Collmer.com/1DI300A030
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"800","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"1.2u","@VCE (test)":"5.0","Package":"Module-s","@I(B) (A) (Test Condition)":"5.0","Circuits Per Package":"1","V(BR)CEO (V)":"400","V(CE)sat Max.(V)":"2.0","R(thJC) (°C/W)":"156m","V(BR)CBO (V)":"400","h(FE) Min. Static Current Gain":"150","t(r) Max. (s) Rise time":"2.0u"}...
971 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300A120
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"2.0k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"3.0u","@VCE (test)":"5.0","Package":"MODULE-var","Circuits Per Package":"1","V(BR)CEO (V)":"1.2k","V(BR)CBO (V)":"1.2k","h(FE) Min. Static Current Gain":"70","t(r) Max. (s) Rise time":"3.0u"}...
884 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300A140
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"2.0k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"3.0u","@VCE (test)":"5.0","Package":"MODULE-var","Circuits Per Package":"1","V(BR)CEO (V)":"1.4k","V(BR)CBO (V)":"1.4k","h(FE) Min. Static Current Gain":"70","t(r) Max. (s) Rise time":"3.0u"}...
885 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300D100
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"2.0k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"3.0u","@VCE (test)":"5.0","Package":"MODULE-var","Circuits Per Package":"1","V(BR)CEO (V)":"1.0k","V(BR)CBO (V)":"1.0k","h(FE) Min. Static Current Gain":"100","t(r) Max. (s) Rise time":"2.5u"}...
885 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300MN050
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"1.4k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"2u","@VCE (test)":"2.5","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"600","V(BR)CBO (V)":"600","h(FE) Min. Static Current Gain":"3k"}...
872 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300MN120
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"2k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"3u","@VCE (test)":"4","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"1.2k","V(BR)CBO (V)":"1.2k","h(FE) Min. Static Current Gain":"1.5k"}...
871 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300MP050
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"1.4k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"2u","@VCE (test)":"2.5","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"600","V(BR)CBO (V)":"600","h(FE) Min. Static Current Gain":"3k"}...
870 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300MP120
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"2k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"3u","@VCE (test)":"4","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"1.2k","V(BR)CBO (V)":"1.2k","h(FE) Min. Static Current Gain":"1.5k"}...
872 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300ZN120
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"2.0k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"2.0u","@VCE (test)":"5.0","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"1.2k","V(BR)CBO (V)":"1.2k","h(FE) Min. Static Current Gain":"100","t(r) Max. (s) Rise time":"3.0u"}...
889 Bytes - 05:47:20, 22 November 2024
Collmer.com/1DI300ZP120
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"2.0k","I(C) Abs.(A) Collector Current":"300","t(f) Max. (s) Fall time.":"2.0u","@VCE (test)":"5.0","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"1.2k","V(BR)CBO (V)":"1.2k","h(FE) Min. Static Current Gain":"100","t(r) Max. (s) Rise time":"3.0u"}...
889 Bytes - 05:47:20, 22 November 2024
Various/1DI300M050
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","I(C) Abs.(A) Collector Current":"300","@VCE (test)":"2.5","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"450","V(BR)CBO (V)":"600","h(FE) Min. Static Current Gain":"3.0k"}...
752 Bytes - 05:47:20, 22 November 2024
Various/1DI300M120
{"@I(C) (A) (Test Condition)":"300","Isolated Case (Y/N)":"Yes","Absolute Max. Power Diss. (W)":"1.4k","I(C) Abs.(A) Collector Current":"300","@VCE (test)":"4.0","Package":"Module-s","Circuits Per Package":"1","V(BR)CEO (V)":"900","h(FE) Min. Static Current Gain":"1.0k"}...
752 Bytes - 05:47:20, 22 November 2024

Documentation and Support

Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:

File NameFile Size (MB)DocumentMOQSupport
1DI300G-120.pdf0.091Request